Cargando…

Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units

Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved...

Descripción completa

Detalles Bibliográficos
Autores principales: Grzyb, Krzysztof, Jasiński, Radosław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612343/
https://www.ncbi.nlm.nih.gov/pubmed/36295469
http://dx.doi.org/10.3390/ma15207404
_version_ 1784819751320551424
author Grzyb, Krzysztof
Jasiński, Radosław
author_facet Grzyb, Krzysztof
Jasiński, Radosław
author_sort Grzyb, Krzysztof
collection PubMed
description Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved aerated concrete (AAC) masonry elements. The primary purpose of the work was to determine the changes in the stiffness of the shear walls and to attempt the empirical distribution of loads on the stiffening walls. The intermediate goals were: a description of the crack morphology and the mechanism of failure, the designation of the stiffening walls’ behavior. It was shown that the first crack formed in the tensile corner of the door opening, and the subsequent cracks formed in the wall without a hole. Based on the changes in the value of the shear deformation angles, the phases of work of the stiffening walls were determined. The presented research results are only a part of an extensive study of stiffening walls in masonry buildings conducted at the Silesian University of Technology.
format Online
Article
Text
id pubmed-9612343
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96123432022-10-28 Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units Grzyb, Krzysztof Jasiński, Radosław Materials (Basel) Article Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved aerated concrete (AAC) masonry elements. The primary purpose of the work was to determine the changes in the stiffness of the shear walls and to attempt the empirical distribution of loads on the stiffening walls. The intermediate goals were: a description of the crack morphology and the mechanism of failure, the designation of the stiffening walls’ behavior. It was shown that the first crack formed in the tensile corner of the door opening, and the subsequent cracks formed in the wall without a hole. Based on the changes in the value of the shear deformation angles, the phases of work of the stiffening walls were determined. The presented research results are only a part of an extensive study of stiffening walls in masonry buildings conducted at the Silesian University of Technology. MDPI 2022-10-21 /pmc/articles/PMC9612343/ /pubmed/36295469 http://dx.doi.org/10.3390/ma15207404 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Grzyb, Krzysztof
Jasiński, Radosław
Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title_full Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title_fullStr Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title_full_unstemmed Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title_short Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
title_sort research on the behavior of stiffening walls in single-storey buildings made of autoclaved aerated concrete (aac) masonry units
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612343/
https://www.ncbi.nlm.nih.gov/pubmed/36295469
http://dx.doi.org/10.3390/ma15207404
work_keys_str_mv AT grzybkrzysztof researchonthebehaviorofstiffeningwallsinsinglestoreybuildingsmadeofautoclavedaeratedconcreteaacmasonryunits
AT jasinskiradosław researchonthebehaviorofstiffeningwallsinsinglestoreybuildingsmadeofautoclavedaeratedconcreteaacmasonryunits