Cargando…
Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units
Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612343/ https://www.ncbi.nlm.nih.gov/pubmed/36295469 http://dx.doi.org/10.3390/ma15207404 |
_version_ | 1784819751320551424 |
---|---|
author | Grzyb, Krzysztof Jasiński, Radosław |
author_facet | Grzyb, Krzysztof Jasiński, Radosław |
author_sort | Grzyb, Krzysztof |
collection | PubMed |
description | Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved aerated concrete (AAC) masonry elements. The primary purpose of the work was to determine the changes in the stiffness of the shear walls and to attempt the empirical distribution of loads on the stiffening walls. The intermediate goals were: a description of the crack morphology and the mechanism of failure, the designation of the stiffening walls’ behavior. It was shown that the first crack formed in the tensile corner of the door opening, and the subsequent cracks formed in the wall without a hole. Based on the changes in the value of the shear deformation angles, the phases of work of the stiffening walls were determined. The presented research results are only a part of an extensive study of stiffening walls in masonry buildings conducted at the Silesian University of Technology. |
format | Online Article Text |
id | pubmed-9612343 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96123432022-10-28 Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units Grzyb, Krzysztof Jasiński, Radosław Materials (Basel) Article Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved aerated concrete (AAC) masonry elements. The primary purpose of the work was to determine the changes in the stiffness of the shear walls and to attempt the empirical distribution of loads on the stiffening walls. The intermediate goals were: a description of the crack morphology and the mechanism of failure, the designation of the stiffening walls’ behavior. It was shown that the first crack formed in the tensile corner of the door opening, and the subsequent cracks formed in the wall without a hole. Based on the changes in the value of the shear deformation angles, the phases of work of the stiffening walls were determined. The presented research results are only a part of an extensive study of stiffening walls in masonry buildings conducted at the Silesian University of Technology. MDPI 2022-10-21 /pmc/articles/PMC9612343/ /pubmed/36295469 http://dx.doi.org/10.3390/ma15207404 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Grzyb, Krzysztof Jasiński, Radosław Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title | Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title_full | Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title_fullStr | Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title_full_unstemmed | Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title_short | Research on the Behavior of Stiffening Walls in Single-Storey Buildings Made of Autoclaved Aerated Concrete (AAC) Masonry Units |
title_sort | research on the behavior of stiffening walls in single-storey buildings made of autoclaved aerated concrete (aac) masonry units |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612343/ https://www.ncbi.nlm.nih.gov/pubmed/36295469 http://dx.doi.org/10.3390/ma15207404 |
work_keys_str_mv | AT grzybkrzysztof researchonthebehaviorofstiffeningwallsinsinglestoreybuildingsmadeofautoclavedaeratedconcreteaacmasonryunits AT jasinskiradosław researchonthebehaviorofstiffeningwallsinsinglestoreybuildingsmadeofautoclavedaeratedconcreteaacmasonryunits |