Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices
The performance of portable or wearable oximeters is affected by improper movement or wear, which causes an error in the blood oxygen concentration calculation. The error comes from external incident stray light or light leakage caused by the improper fit of the sensor to the skin. This study aimed...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612374/ https://www.ncbi.nlm.nih.gov/pubmed/36296095 http://dx.doi.org/10.3390/mi13101742 |
_version_ | 1784819759436529664 |
---|---|
author | Kuo, Wen-Cheng Wu, Tzu-Chien Wang, Jun-Sheng |
author_facet | Kuo, Wen-Cheng Wu, Tzu-Chien Wang, Jun-Sheng |
author_sort | Kuo, Wen-Cheng |
collection | PubMed |
description | The performance of portable or wearable oximeters is affected by improper movement or wear, which causes an error in the blood oxygen concentration calculation. The error comes from external incident stray light or light leakage caused by the improper fit of the sensor to the skin. This study aimed to develop a flexible blood oxygen sensing system with a 3 × 3 array that uses a reflective-type blood oxygen sensing chip to sequentially measure the blood oxygen levels at nine locations through a time division pulse modulation method. Each sensing chip has light transmission and receiving parts. A flip chip package was used to integrate the sensing chip, and a flexible parylene substrate that could fit the curvature of the wrist and locate the array of photo diodes around the radial artery of the wrist was used. By scanning the sensor array in dynamic behavior, the correct light intensity can be extracted to obtain the blood oxygen concentration and prevent errors due to improper fit or sensor movement during exercise. |
format | Online Article Text |
id | pubmed-9612374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96123742022-10-28 Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices Kuo, Wen-Cheng Wu, Tzu-Chien Wang, Jun-Sheng Micromachines (Basel) Article The performance of portable or wearable oximeters is affected by improper movement or wear, which causes an error in the blood oxygen concentration calculation. The error comes from external incident stray light or light leakage caused by the improper fit of the sensor to the skin. This study aimed to develop a flexible blood oxygen sensing system with a 3 × 3 array that uses a reflective-type blood oxygen sensing chip to sequentially measure the blood oxygen levels at nine locations through a time division pulse modulation method. Each sensing chip has light transmission and receiving parts. A flip chip package was used to integrate the sensing chip, and a flexible parylene substrate that could fit the curvature of the wrist and locate the array of photo diodes around the radial artery of the wrist was used. By scanning the sensor array in dynamic behavior, the correct light intensity can be extracted to obtain the blood oxygen concentration and prevent errors due to improper fit or sensor movement during exercise. MDPI 2022-10-14 /pmc/articles/PMC9612374/ /pubmed/36296095 http://dx.doi.org/10.3390/mi13101742 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kuo, Wen-Cheng Wu, Tzu-Chien Wang, Jun-Sheng Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title | Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title_full | Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title_fullStr | Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title_full_unstemmed | Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title_short | Design and Application of a Flexible Blood Oxygen Sensing Array for Wearable Devices |
title_sort | design and application of a flexible blood oxygen sensing array for wearable devices |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612374/ https://www.ncbi.nlm.nih.gov/pubmed/36296095 http://dx.doi.org/10.3390/mi13101742 |
work_keys_str_mv | AT kuowencheng designandapplicationofaflexiblebloodoxygensensingarrayforwearabledevices AT wutzuchien designandapplicationofaflexiblebloodoxygensensingarrayforwearabledevices AT wangjunsheng designandapplicationofaflexiblebloodoxygensensingarrayforwearabledevices |