Cargando…

Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy

Decompressive craniectomy (DC) is widely used to treat intracranial hypertension following severe head injury. However, impairments of cerebrospinal fluid (CSF) hydrodynamics such as hydrocephalus and subdural effusion are common complications that occur after DC. Therefore, monitoring of intracrani...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Meng, Zhang, Jiahui, Li, Huanting, Mu, Shuang, Liu, Wei, Deng, Wenshuai, Liu, Xin, He, Zhaozhong, Gong, Anjing, Feng, Yugong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612685/
https://www.ncbi.nlm.nih.gov/pubmed/35894445
http://dx.doi.org/10.1097/SCS.0000000000008785
_version_ 1784819830732357632
author Zhu, Meng
Zhang, Jiahui
Li, Huanting
Mu, Shuang
Liu, Wei
Deng, Wenshuai
Liu, Xin
He, Zhaozhong
Gong, Anjing
Feng, Yugong
author_facet Zhu, Meng
Zhang, Jiahui
Li, Huanting
Mu, Shuang
Liu, Wei
Deng, Wenshuai
Liu, Xin
He, Zhaozhong
Gong, Anjing
Feng, Yugong
author_sort Zhu, Meng
collection PubMed
description Decompressive craniectomy (DC) is widely used to treat intracranial hypertension following severe head injury. However, impairments of cerebrospinal fluid (CSF) hydrodynamics such as hydrocephalus and subdural effusion are common complications that occur after DC. Therefore, monitoring of intracranial pressure is a staple of neurocritical care post-DC. The aim of this study was to assess the usefulness of transcranial duplex sonography (TDS) for serial monitoring and management of CSF disorders after DC. METHODS: A total of 100 patients who underwent DC between June 2016 and May 2019 were recruited for the study. Transcranial duplex sonography examinations were performed between 1-day and 1-year post-DC. Transcranial duplex sonography was mainly used for monitoring changes in ventricle size and morphology, and also to monitor intraventricular hemorrhage, hydrocephalus, intracranial hygromas, and ventricle changes during CSF release procedures. RESULTS: A total of 456 TDS examinations were performed on patients after DC. Of these, 402 were performed in the neuro–intensive care unit. Two patients had intraventricular hemorrhage and underwent TDS-guided external ventricular drainage. Twenty-nine patients were diagnosed with hydrocephalus. The results of TDS were consistent with those of cranial computed tomography. Three cases of ventriculoperitoneal shunt and 1 case of lumbar peritoneal shunt underwent valve pressure reset according to TDS, to obtain satisfactory ventricle size. Transcranial duplex sonography was used to monitor ventricle changes and control drainage volume during CSF release procedures, including 2 external ventricular drainage, 6 external lumbar drainage, and 10 lumbar punctures. Eighteen patients were detected with single or multiple intracranial effusions, including 16 subdural hygromas, 5 longitudinal fissure hygromas, and 6 brain cysts. CONCLUSIONS: Transcranial duplex sonography can efficiently help monitor changes in ventricle size and morphology and intracranial effusions. Due to its noninvasive nature, suitability for bedside application, real-time, and inexpensiveness, TDS can significantly replace cranial computed tomography and become part of the patient’s daily inspection work after DC.
format Online
Article
Text
id pubmed-9612685
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-96126852022-11-04 Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy Zhu, Meng Zhang, Jiahui Li, Huanting Mu, Shuang Liu, Wei Deng, Wenshuai Liu, Xin He, Zhaozhong Gong, Anjing Feng, Yugong J Craniofac Surg Original Articles Decompressive craniectomy (DC) is widely used to treat intracranial hypertension following severe head injury. However, impairments of cerebrospinal fluid (CSF) hydrodynamics such as hydrocephalus and subdural effusion are common complications that occur after DC. Therefore, monitoring of intracranial pressure is a staple of neurocritical care post-DC. The aim of this study was to assess the usefulness of transcranial duplex sonography (TDS) for serial monitoring and management of CSF disorders after DC. METHODS: A total of 100 patients who underwent DC between June 2016 and May 2019 were recruited for the study. Transcranial duplex sonography examinations were performed between 1-day and 1-year post-DC. Transcranial duplex sonography was mainly used for monitoring changes in ventricle size and morphology, and also to monitor intraventricular hemorrhage, hydrocephalus, intracranial hygromas, and ventricle changes during CSF release procedures. RESULTS: A total of 456 TDS examinations were performed on patients after DC. Of these, 402 were performed in the neuro–intensive care unit. Two patients had intraventricular hemorrhage and underwent TDS-guided external ventricular drainage. Twenty-nine patients were diagnosed with hydrocephalus. The results of TDS were consistent with those of cranial computed tomography. Three cases of ventriculoperitoneal shunt and 1 case of lumbar peritoneal shunt underwent valve pressure reset according to TDS, to obtain satisfactory ventricle size. Transcranial duplex sonography was used to monitor ventricle changes and control drainage volume during CSF release procedures, including 2 external ventricular drainage, 6 external lumbar drainage, and 10 lumbar punctures. Eighteen patients were detected with single or multiple intracranial effusions, including 16 subdural hygromas, 5 longitudinal fissure hygromas, and 6 brain cysts. CONCLUSIONS: Transcranial duplex sonography can efficiently help monitor changes in ventricle size and morphology and intracranial effusions. Due to its noninvasive nature, suitability for bedside application, real-time, and inexpensiveness, TDS can significantly replace cranial computed tomography and become part of the patient’s daily inspection work after DC. Lippincott Williams & Wilkins 2022 2022-07-27 /pmc/articles/PMC9612685/ /pubmed/35894445 http://dx.doi.org/10.1097/SCS.0000000000008785 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of Mutaz B. Habal, MD. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Articles
Zhu, Meng
Zhang, Jiahui
Li, Huanting
Mu, Shuang
Liu, Wei
Deng, Wenshuai
Liu, Xin
He, Zhaozhong
Gong, Anjing
Feng, Yugong
Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title_full Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title_fullStr Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title_full_unstemmed Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title_short Ultrasonography for Serial Monitoring and Management of Cerebrospinal Fluid Dynamic Disorders After Decompressive Craniectomy
title_sort ultrasonography for serial monitoring and management of cerebrospinal fluid dynamic disorders after decompressive craniectomy
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9612685/
https://www.ncbi.nlm.nih.gov/pubmed/35894445
http://dx.doi.org/10.1097/SCS.0000000000008785
work_keys_str_mv AT zhumeng ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT zhangjiahui ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT lihuanting ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT mushuang ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT liuwei ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT dengwenshuai ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT liuxin ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT hezhaozhong ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT gonganjing ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy
AT fengyugong ultrasonographyforserialmonitoringandmanagementofcerebrospinalfluiddynamicdisordersafterdecompressivecraniectomy