Cargando…
Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana
INTRODUCTION: Administering the right dose of medications is essential in avoiding potentially life-threatening adverse drug reactions. Industry guidelines for manufacturers of oral, over-the-counter, and liquid medications recommend including dose-delivery devices with packaging to limit dosing ina...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613386/ https://www.ncbi.nlm.nih.gov/pubmed/36311285 http://dx.doi.org/10.1155/2022/9223858 |
_version_ | 1784819977828696064 |
---|---|
author | Saaka, Yussif Nyamadi, David M. Amekyeh, Hilda Mensah, Adelaide |
author_facet | Saaka, Yussif Nyamadi, David M. Amekyeh, Hilda Mensah, Adelaide |
author_sort | Saaka, Yussif |
collection | PubMed |
description | INTRODUCTION: Administering the right dose of medications is essential in avoiding potentially life-threatening adverse drug reactions. Industry guidelines for manufacturers of oral, over-the-counter, and liquid medications recommend including dose-delivery devices with packaging to limit dosing inaccuracy. This study describes the prevalence and accuracy of dosing devices packaged with oral liquid medications in the Ho municipality of Ghana. METHODS: Dosing device accuracy was determined after deviation of the measured volume from the expected volume was evaluated using the United States Pharmacopoeia criteria. RESULTS: A total of 78.6% of the oral liquid medications were packaged with a dosing device. The most common dosing devices were cups (83.6%), followed by spoons (14.3%), droppers (1.4%), and syringes (0.7%). The volumes measured with cups (5.14 ± 0.52 mL, p = 0.006) and spoons (5.3 ± 0.67 mL, p < 0.001) were significantly different from the desired 5 mL volume; this was dissimilar to the volume measured using syringes (5.01 ± 0.02 mL, p > 0.999). Further, the measured volumes for 38.6% and 72.2% of the cups and spoons, respectively, deviated by more than 15% of 5 mL. CONCLUSION: Dosing cups and spoons are associated with significant inaccuracy. Yet, manufacturers continually favour them over syringes in packaging for oral liquid medications. This is unacceptable and of considerable concern due to the risk of variations in therapeutic outcomes. Therefore, strict regulatory directives on the inclusion of accurate dosing devices in the packaging of oral liquid medicines are needed to reduce the possibility of medication errors. |
format | Online Article Text |
id | pubmed-9613386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-96133862022-10-28 Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana Saaka, Yussif Nyamadi, David M. Amekyeh, Hilda Mensah, Adelaide Scientifica (Cairo) Research Article INTRODUCTION: Administering the right dose of medications is essential in avoiding potentially life-threatening adverse drug reactions. Industry guidelines for manufacturers of oral, over-the-counter, and liquid medications recommend including dose-delivery devices with packaging to limit dosing inaccuracy. This study describes the prevalence and accuracy of dosing devices packaged with oral liquid medications in the Ho municipality of Ghana. METHODS: Dosing device accuracy was determined after deviation of the measured volume from the expected volume was evaluated using the United States Pharmacopoeia criteria. RESULTS: A total of 78.6% of the oral liquid medications were packaged with a dosing device. The most common dosing devices were cups (83.6%), followed by spoons (14.3%), droppers (1.4%), and syringes (0.7%). The volumes measured with cups (5.14 ± 0.52 mL, p = 0.006) and spoons (5.3 ± 0.67 mL, p < 0.001) were significantly different from the desired 5 mL volume; this was dissimilar to the volume measured using syringes (5.01 ± 0.02 mL, p > 0.999). Further, the measured volumes for 38.6% and 72.2% of the cups and spoons, respectively, deviated by more than 15% of 5 mL. CONCLUSION: Dosing cups and spoons are associated with significant inaccuracy. Yet, manufacturers continually favour them over syringes in packaging for oral liquid medications. This is unacceptable and of considerable concern due to the risk of variations in therapeutic outcomes. Therefore, strict regulatory directives on the inclusion of accurate dosing devices in the packaging of oral liquid medicines are needed to reduce the possibility of medication errors. Hindawi 2022-10-20 /pmc/articles/PMC9613386/ /pubmed/36311285 http://dx.doi.org/10.1155/2022/9223858 Text en Copyright © 2022 Yussif Saaka et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Saaka, Yussif Nyamadi, David M. Amekyeh, Hilda Mensah, Adelaide Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title | Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title_full | Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title_fullStr | Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title_full_unstemmed | Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title_short | Assessment of the Availability and Accuracy of Dosing Devices Packaged with Oral Liquid Medications in the Ho Municipality of Ghana |
title_sort | assessment of the availability and accuracy of dosing devices packaged with oral liquid medications in the ho municipality of ghana |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613386/ https://www.ncbi.nlm.nih.gov/pubmed/36311285 http://dx.doi.org/10.1155/2022/9223858 |
work_keys_str_mv | AT saakayussif assessmentoftheavailabilityandaccuracyofdosingdevicespackagedwithoralliquidmedicationsinthehomunicipalityofghana AT nyamadidavidm assessmentoftheavailabilityandaccuracyofdosingdevicespackagedwithoralliquidmedicationsinthehomunicipalityofghana AT amekyehhilda assessmentoftheavailabilityandaccuracyofdosingdevicespackagedwithoralliquidmedicationsinthehomunicipalityofghana AT mensahadelaide assessmentoftheavailabilityandaccuracyofdosingdevicespackagedwithoralliquidmedicationsinthehomunicipalityofghana |