Cargando…

Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study

BACKGROUND: Few studies have been conducted to examine the displacement characteristics of both-column acetabular fractures (BCAFs). The goal of this study was to investigate the displacement pattern of anterior column (AC) and posterior column (PC) fragments in BCAFs using 3D virtual software. MATE...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Pengyu, Guo, Junfei, Wang, Zhongzheng, Tian, Siyu, Zhao, Kuo, Yin, Yingchao, Hou, Zhiyong, Zhang, Yingze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613399/
https://www.ncbi.nlm.nih.gov/pubmed/36312856
http://dx.doi.org/10.1155/2022/3556357
_version_ 1784819981077184512
author Ye, Pengyu
Guo, Junfei
Wang, Zhongzheng
Tian, Siyu
Zhao, Kuo
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
author_facet Ye, Pengyu
Guo, Junfei
Wang, Zhongzheng
Tian, Siyu
Zhao, Kuo
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
author_sort Ye, Pengyu
collection PubMed
description BACKGROUND: Few studies have been conducted to examine the displacement characteristics of both-column acetabular fractures (BCAFs). The goal of this study was to investigate the displacement pattern of anterior column (AC) and posterior column (PC) fragments in BCAFs using 3D virtual software. MATERIALS AND METHODS: BCAFs were retrospectively reviewed, and 81 patients were enrolled. Computed tomography (CT) images were imported into Mimics software. A 3D model of each pelvis was generated. Four marked points and the rotation angle of each of the injured ACs and PCs were identified. The fracture fragments were reduced virtually using the software, and the change in coordinates of the marked points after reduction was recorded while the rotation angle was measured. The measurements of positional and directional displacement were analysed using the Mann–Whitney U test and the binomial test, respectively. RESULTS: There was a propensity for AC fragments to shift superomedially and to rotate externally (p < 0.001). Additionally, the posteroinferior fracture area of AC fragments showed the greatest displacement (p < 0.05). PC fragments moved superomedially (p < 0.001) and moved more at the proximal end than the distal end (p < 0.001). PC displacement was always accompanied by internal rotation (p < 0.001). Greater AC displacement was observed in the fracture area further away from the acetabulum (p < 0.05). Greater rotation was observed for the AC than the PC (p < 0.001). CONCLUSION: After a BCAF occurs, there are regular patterns regarding the direction and distance of AC and PC fragment displacement. Information on these patterns may provide insight into the injury mechanism and fracture morphology and facilitate surgical decision-making for orthopaedic trauma surgeons.
format Online
Article
Text
id pubmed-9613399
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-96133992022-10-28 Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study Ye, Pengyu Guo, Junfei Wang, Zhongzheng Tian, Siyu Zhao, Kuo Yin, Yingchao Hou, Zhiyong Zhang, Yingze Biomed Res Int Research Article BACKGROUND: Few studies have been conducted to examine the displacement characteristics of both-column acetabular fractures (BCAFs). The goal of this study was to investigate the displacement pattern of anterior column (AC) and posterior column (PC) fragments in BCAFs using 3D virtual software. MATERIALS AND METHODS: BCAFs were retrospectively reviewed, and 81 patients were enrolled. Computed tomography (CT) images were imported into Mimics software. A 3D model of each pelvis was generated. Four marked points and the rotation angle of each of the injured ACs and PCs were identified. The fracture fragments were reduced virtually using the software, and the change in coordinates of the marked points after reduction was recorded while the rotation angle was measured. The measurements of positional and directional displacement were analysed using the Mann–Whitney U test and the binomial test, respectively. RESULTS: There was a propensity for AC fragments to shift superomedially and to rotate externally (p < 0.001). Additionally, the posteroinferior fracture area of AC fragments showed the greatest displacement (p < 0.05). PC fragments moved superomedially (p < 0.001) and moved more at the proximal end than the distal end (p < 0.001). PC displacement was always accompanied by internal rotation (p < 0.001). Greater AC displacement was observed in the fracture area further away from the acetabulum (p < 0.05). Greater rotation was observed for the AC than the PC (p < 0.001). CONCLUSION: After a BCAF occurs, there are regular patterns regarding the direction and distance of AC and PC fragment displacement. Information on these patterns may provide insight into the injury mechanism and fracture morphology and facilitate surgical decision-making for orthopaedic trauma surgeons. Hindawi 2022-10-20 /pmc/articles/PMC9613399/ /pubmed/36312856 http://dx.doi.org/10.1155/2022/3556357 Text en Copyright © 2022 Pengyu Ye et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ye, Pengyu
Guo, Junfei
Wang, Zhongzheng
Tian, Siyu
Zhao, Kuo
Yin, Yingchao
Hou, Zhiyong
Zhang, Yingze
Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title_full Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title_fullStr Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title_full_unstemmed Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title_short Displacement Pattern of Anterior and Posterior Column Fragments in Both-Column Acetabular Fractures: A 3D Reconstruction-Based Study
title_sort displacement pattern of anterior and posterior column fragments in both-column acetabular fractures: a 3d reconstruction-based study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613399/
https://www.ncbi.nlm.nih.gov/pubmed/36312856
http://dx.doi.org/10.1155/2022/3556357
work_keys_str_mv AT yepengyu displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT guojunfei displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT wangzhongzheng displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT tiansiyu displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT zhaokuo displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT yinyingchao displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT houzhiyong displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy
AT zhangyingze displacementpatternofanteriorandposteriorcolumnfragmentsinbothcolumnacetabularfracturesa3dreconstructionbasedstudy