Cargando…
Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study
OBJECTIVES: Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is diff...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Society of Coloproctology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613409/ https://www.ncbi.nlm.nih.gov/pubmed/36348946 http://dx.doi.org/10.23922/jarc.2022-005 |
_version_ | 1784819982564065280 |
---|---|
author | Ochiai, Yorinari Odagiri, Hiroyuki Hayasaka, Junnosuke Okamura, Takayuki Suzuki, Yugo Mitsunaga, Yutaka Fuchinoue, Kazuhiro Tanaka, Masami Nomura, Kosuke Yamashita, Satoshi Matsui, Akira Kikuchi, Daisuke Hoteya, Shu |
author_facet | Ochiai, Yorinari Odagiri, Hiroyuki Hayasaka, Junnosuke Okamura, Takayuki Suzuki, Yugo Mitsunaga, Yutaka Fuchinoue, Kazuhiro Tanaka, Masami Nomura, Kosuke Yamashita, Satoshi Matsui, Akira Kikuchi, Daisuke Hoteya, Shu |
author_sort | Ochiai, Yorinari |
collection | PubMed |
description | OBJECTIVES: Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy. METHODS: This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-caliber colonoscope (PCF-PQ260L) were randomly selected for the control group from procedures performed by the same 11 endoscopists. We compared the cecal intubation rate and other outcomes, such as insertion time, between the two groups. RESULTS: The median age of the patients was 72 and 69 years, with 8 and 26 males in the SIF and control groups, respectively. The median body mass index was 21.6 and 22.7 kg/m(2) in the SIF and control groups, respectively. There were no significant differences in the patient backgrounds between the groups, except for the reason for incomplete colonoscopy (p = 0.048). The cecal intubation rate was 78.9% (15/19 procedures) and 92.1% (35/38 procedures) in the SIF and control groups, respectively. CONCLUSIONS: This study revealed the real-world experience and feasibility of rescue colonoscopy using SIF-H290S, which could be a potential rescue device option after incomplete colonoscopy. |
format | Online Article Text |
id | pubmed-9613409 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Japan Society of Coloproctology |
record_format | MEDLINE/PubMed |
spelling | pubmed-96134092022-11-07 Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study Ochiai, Yorinari Odagiri, Hiroyuki Hayasaka, Junnosuke Okamura, Takayuki Suzuki, Yugo Mitsunaga, Yutaka Fuchinoue, Kazuhiro Tanaka, Masami Nomura, Kosuke Yamashita, Satoshi Matsui, Akira Kikuchi, Daisuke Hoteya, Shu J Anus Rectum Colon Clinical Research OBJECTIVES: Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy. METHODS: This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-caliber colonoscope (PCF-PQ260L) were randomly selected for the control group from procedures performed by the same 11 endoscopists. We compared the cecal intubation rate and other outcomes, such as insertion time, between the two groups. RESULTS: The median age of the patients was 72 and 69 years, with 8 and 26 males in the SIF and control groups, respectively. The median body mass index was 21.6 and 22.7 kg/m(2) in the SIF and control groups, respectively. There were no significant differences in the patient backgrounds between the groups, except for the reason for incomplete colonoscopy (p = 0.048). The cecal intubation rate was 78.9% (15/19 procedures) and 92.1% (35/38 procedures) in the SIF and control groups, respectively. CONCLUSIONS: This study revealed the real-world experience and feasibility of rescue colonoscopy using SIF-H290S, which could be a potential rescue device option after incomplete colonoscopy. The Japan Society of Coloproctology 2022-10-27 /pmc/articles/PMC9613409/ /pubmed/36348946 http://dx.doi.org/10.23922/jarc.2022-005 Text en Copyright © 2022 The Japan Society of Coloproctology https://creativecommons.org/licenses/by-nc-nd/4.0/Journal of the Anus, Rectum and Colon is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Clinical Research Ochiai, Yorinari Odagiri, Hiroyuki Hayasaka, Junnosuke Okamura, Takayuki Suzuki, Yugo Mitsunaga, Yutaka Fuchinoue, Kazuhiro Tanaka, Masami Nomura, Kosuke Yamashita, Satoshi Matsui, Akira Kikuchi, Daisuke Hoteya, Shu Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title | Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title_full | Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title_fullStr | Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title_full_unstemmed | Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title_short | Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete Colonoscopy: A Single-center Retrospective Pilot Study |
title_sort | feasibility of rescue colonoscopy using a short-type enteroscope (sif-h290s) without overtube after incomplete colonoscopy: a single-center retrospective pilot study |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9613409/ https://www.ncbi.nlm.nih.gov/pubmed/36348946 http://dx.doi.org/10.23922/jarc.2022-005 |
work_keys_str_mv | AT ochiaiyorinari feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT odagirihiroyuki feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT hayasakajunnosuke feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT okamuratakayuki feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT suzukiyugo feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT mitsunagayutaka feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT fuchinouekazuhiro feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT tanakamasami feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT nomurakosuke feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT yamashitasatoshi feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT matsuiakira feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT kikuchidaisuke feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy AT hoteyashu feasibilityofrescuecolonoscopyusingashorttypeenteroscopesifh290swithoutovertubeafterincompletecolonoscopyasinglecenterretrospectivepilotstudy |