Assessment of cleaning stethoscopes using UV-C sanitation

Background: It is well established that stethoscopes harbor pathogenic bacteria species. Within hospital settings, these pathogens can be rapidly transmitted from room to room and can cause harm in vulnerable populations. The current literature demonstrates that disinfecting stethoscopes with isopro...

Descripción completa

Detalles Bibliográficos
Autores principales: Carmack, Austin, Sundaram, Niteesh, Cagir, Burt, Lanning, Cathy, Robinson, Kayla, Rizzo, Anne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9614851/
http://dx.doi.org/10.1017/ash.2022.143
_version_ 1784820284940877824
author Carmack, Austin
Sundaram, Niteesh
Cagir, Burt
Lanning, Cathy
Robinson, Kayla
Rizzo, Anne
author_facet Carmack, Austin
Sundaram, Niteesh
Cagir, Burt
Lanning, Cathy
Robinson, Kayla
Rizzo, Anne
author_sort Carmack, Austin
collection PubMed
description Background: It is well established that stethoscopes harbor pathogenic bacteria species. Within hospital settings, these pathogens can be rapidly transmitted from room to room and can cause harm in vulnerable populations. The current literature demonstrates that disinfecting stethoscopes with isopropanol kills 99% of all bacteria. However, in practice this rarely occurs and disinfection is subject to user error. We assessed the efficacy of ultraviolet germicidal irradiation (UV-C) at decontaminating stethoscopes used at our rural healthcare system along with the cleaning habits of their users. Methods: Stethoscopes were randomly selected from the clinical staff of our hospital’s largest nursing unit. The stethoscopes were each swabbed for culture then exposed to UV-C for 20 seconds and sampled again. Users were asked to complete a survey during this process. Samples were then cultivated on tryptone soya broth (TSB) agar, and all growth was sent for identification via matrix-assisted laser desorption/ionization (MALDI-TOF). Later, the protocol was repeated to assess cleaning efficacy of the isopropanol wipes commonly used in our hospital. We collected pre- and postintervention samples after cleaning vigorously for 3 minutes according to the manufacturer’s guidelines. The samples were classified as follows: “cleaner” if the number of colonies decreased after sanitation, “sterilized” if the number of colonies decreased to zero, “no change” if the number of colonies stayed the same, and “no assessment” if there was no preintervention growth. Several samples “increased” in CFU count after the intervention, likely due to incomplete sampling, contamination, or incomplete penetration of UV-C. The Fisher exact test was used to analyze the effectiveness of the stethoscope sanitation techniques. Results: In total, 60 samples (33 used for analysis) were obtained from stethoscopes cleaned with UV-C (Fig. 1). Moreover, 34 samples (28 used for analysis) were obtained from stethoscopes cleaned with isopropanol (Fig. 2). Both UV-C (93.9% vs 6.1%; P < .01) and isopropanol (100% vs 0%; P < .01) resulted in a significant decrease in bacterial colonization on stethoscopes. UV-C was not more effective at sanitizing stethoscopes than isopropanol (93.9% vs 100%; P = .50). Conclusions: Both UV-C and isopropanol were effective at cleaning hospital stethoscopes. Given that UV-C is not subject to user error and that it takes less time to clean a stethoscope than isopropanol, it may be the superior option in a clinical setting. Funding: None Disclosures: None
format Online
Article
Text
id pubmed-9614851
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-96148512022-10-29 Assessment of cleaning stethoscopes using UV-C sanitation Carmack, Austin Sundaram, Niteesh Cagir, Burt Lanning, Cathy Robinson, Kayla Rizzo, Anne Antimicrob Steward Healthc Epidemiol Disinfection/Sterilization Background: It is well established that stethoscopes harbor pathogenic bacteria species. Within hospital settings, these pathogens can be rapidly transmitted from room to room and can cause harm in vulnerable populations. The current literature demonstrates that disinfecting stethoscopes with isopropanol kills 99% of all bacteria. However, in practice this rarely occurs and disinfection is subject to user error. We assessed the efficacy of ultraviolet germicidal irradiation (UV-C) at decontaminating stethoscopes used at our rural healthcare system along with the cleaning habits of their users. Methods: Stethoscopes were randomly selected from the clinical staff of our hospital’s largest nursing unit. The stethoscopes were each swabbed for culture then exposed to UV-C for 20 seconds and sampled again. Users were asked to complete a survey during this process. Samples were then cultivated on tryptone soya broth (TSB) agar, and all growth was sent for identification via matrix-assisted laser desorption/ionization (MALDI-TOF). Later, the protocol was repeated to assess cleaning efficacy of the isopropanol wipes commonly used in our hospital. We collected pre- and postintervention samples after cleaning vigorously for 3 minutes according to the manufacturer’s guidelines. The samples were classified as follows: “cleaner” if the number of colonies decreased after sanitation, “sterilized” if the number of colonies decreased to zero, “no change” if the number of colonies stayed the same, and “no assessment” if there was no preintervention growth. Several samples “increased” in CFU count after the intervention, likely due to incomplete sampling, contamination, or incomplete penetration of UV-C. The Fisher exact test was used to analyze the effectiveness of the stethoscope sanitation techniques. Results: In total, 60 samples (33 used for analysis) were obtained from stethoscopes cleaned with UV-C (Fig. 1). Moreover, 34 samples (28 used for analysis) were obtained from stethoscopes cleaned with isopropanol (Fig. 2). Both UV-C (93.9% vs 6.1%; P < .01) and isopropanol (100% vs 0%; P < .01) resulted in a significant decrease in bacterial colonization on stethoscopes. UV-C was not more effective at sanitizing stethoscopes than isopropanol (93.9% vs 100%; P = .50). Conclusions: Both UV-C and isopropanol were effective at cleaning hospital stethoscopes. Given that UV-C is not subject to user error and that it takes less time to clean a stethoscope than isopropanol, it may be the superior option in a clinical setting. Funding: None Disclosures: None Cambridge University Press 2022-05-16 /pmc/articles/PMC9614851/ http://dx.doi.org/10.1017/ash.2022.143 Text en © The Society for Healthcare Epidemiology of America 2022 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Disinfection/Sterilization
Carmack, Austin
Sundaram, Niteesh
Cagir, Burt
Lanning, Cathy
Robinson, Kayla
Rizzo, Anne
Assessment of cleaning stethoscopes using UV-C sanitation
title Assessment of cleaning stethoscopes using UV-C sanitation
title_full Assessment of cleaning stethoscopes using UV-C sanitation
title_fullStr Assessment of cleaning stethoscopes using UV-C sanitation
title_full_unstemmed Assessment of cleaning stethoscopes using UV-C sanitation
title_short Assessment of cleaning stethoscopes using UV-C sanitation
title_sort assessment of cleaning stethoscopes using uv-c sanitation
topic Disinfection/Sterilization
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9614851/
http://dx.doi.org/10.1017/ash.2022.143
work_keys_str_mv AT carmackaustin assessmentofcleaningstethoscopesusinguvcsanitation
AT sundaramniteesh assessmentofcleaningstethoscopesusinguvcsanitation
AT cagirburt assessmentofcleaningstethoscopesusinguvcsanitation
AT lanningcathy assessmentofcleaningstethoscopesusinguvcsanitation
AT robinsonkayla assessmentofcleaningstethoscopesusinguvcsanitation
AT rizzoanne assessmentofcleaningstethoscopesusinguvcsanitation