Cargando…
Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry
In this study, we developed an easily operable quantification method for 21 plant-derived alkaloids in human serum by automatic sample preparation and liquid chromatography–tandem mass spectrometry. We designed to perform parallel sample preparation by a developed apparatus, which increased sample t...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9617228/ https://www.ncbi.nlm.nih.gov/pubmed/36341308 http://dx.doi.org/10.1007/s10337-022-04212-5 |
_version_ | 1784820794850803712 |
---|---|
author | Taniguchi, Masaru Takamura, Naoki Watanabe, Tsutomu Ishimaru, Reiko Chinaka, Satoshi Miki, Akihiro Miyazaki, Hitoshi Tsuchihashi, Hitoshi Zaitsu, Kei |
author_facet | Taniguchi, Masaru Takamura, Naoki Watanabe, Tsutomu Ishimaru, Reiko Chinaka, Satoshi Miki, Akihiro Miyazaki, Hitoshi Tsuchihashi, Hitoshi Zaitsu, Kei |
author_sort | Taniguchi, Masaru |
collection | PubMed |
description | In this study, we developed an easily operable quantification method for 21 plant-derived alkaloids in human serum by automatic sample preparation and liquid chromatography–tandem mass spectrometry. We designed to perform parallel sample preparation by a developed apparatus, which increased sample throughput. We conducted an automatic sample preparation through de-proteinization with 0.1% formic acid in methanol and achieved recovery rates of 89–107% (2.0–14% RSD) for all targeted analytes, demonstrating its high repeatability. The method validation results were satisfactory as follows: the linearity (r(2)) of each calibration curve ranged from 0.978 to 1.000; the inter- and intra-day accuracies were 89.0–125% and 82.1–110%, respectively; the inter- and intra-day precisions were below 13% and 10%, respectively. Additionally, the lower limits of detection and quantification were 0.0044–0.047 and 0.013–0.14 ng/mL, respectively. Finally, the developed method was applied to pseudo-protoveratrine A poisoning serum and pseudo-colchicine poisoning serum, which were prepared by diluting acute-poisoning mice serum with human serum. Our method successfully quantitated protoveratrine A (0.15–0.25 ng/mL) and colchicine (4.8–6.0 ng/mL). Thus, our method is essential for prompt clinical treatment and critical care on patient in acute intoxication cases caused by plant-derived alkaloids. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10337-022-04212-5. |
format | Online Article Text |
id | pubmed-9617228 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-96172282022-10-31 Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry Taniguchi, Masaru Takamura, Naoki Watanabe, Tsutomu Ishimaru, Reiko Chinaka, Satoshi Miki, Akihiro Miyazaki, Hitoshi Tsuchihashi, Hitoshi Zaitsu, Kei Chromatographia Original In this study, we developed an easily operable quantification method for 21 plant-derived alkaloids in human serum by automatic sample preparation and liquid chromatography–tandem mass spectrometry. We designed to perform parallel sample preparation by a developed apparatus, which increased sample throughput. We conducted an automatic sample preparation through de-proteinization with 0.1% formic acid in methanol and achieved recovery rates of 89–107% (2.0–14% RSD) for all targeted analytes, demonstrating its high repeatability. The method validation results were satisfactory as follows: the linearity (r(2)) of each calibration curve ranged from 0.978 to 1.000; the inter- and intra-day accuracies were 89.0–125% and 82.1–110%, respectively; the inter- and intra-day precisions were below 13% and 10%, respectively. Additionally, the lower limits of detection and quantification were 0.0044–0.047 and 0.013–0.14 ng/mL, respectively. Finally, the developed method was applied to pseudo-protoveratrine A poisoning serum and pseudo-colchicine poisoning serum, which were prepared by diluting acute-poisoning mice serum with human serum. Our method successfully quantitated protoveratrine A (0.15–0.25 ng/mL) and colchicine (4.8–6.0 ng/mL). Thus, our method is essential for prompt clinical treatment and critical care on patient in acute intoxication cases caused by plant-derived alkaloids. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10337-022-04212-5. Springer Berlin Heidelberg 2022-10-29 2022 /pmc/articles/PMC9617228/ /pubmed/36341308 http://dx.doi.org/10.1007/s10337-022-04212-5 Text en © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2022, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Taniguchi, Masaru Takamura, Naoki Watanabe, Tsutomu Ishimaru, Reiko Chinaka, Satoshi Miki, Akihiro Miyazaki, Hitoshi Tsuchihashi, Hitoshi Zaitsu, Kei Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title | Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title_full | Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title_fullStr | Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title_full_unstemmed | Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title_short | Easily Operable Quantification Method of 21 Plant-Derived Alkaloids in Human Serum by Automatic Sample Preparation and Liquid Chromatography–Tandem Mass Spectrometry |
title_sort | easily operable quantification method of 21 plant-derived alkaloids in human serum by automatic sample preparation and liquid chromatography–tandem mass spectrometry |
topic | Original |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9617228/ https://www.ncbi.nlm.nih.gov/pubmed/36341308 http://dx.doi.org/10.1007/s10337-022-04212-5 |
work_keys_str_mv | AT taniguchimasaru easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT takamuranaoki easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT watanabetsutomu easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT ishimarureiko easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT chinakasatoshi easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT mikiakihiro easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT miyazakihitoshi easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT tsuchihashihitoshi easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry AT zaitsukei easilyoperablequantificationmethodof21plantderivedalkaloidsinhumanserumbyautomaticsamplepreparationandliquidchromatographytandemmassspectrometry |