Cargando…
A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection
BACKGROUND: Open reduction and internal fixation have been frequently applied for displaced midshaft clavicular fracture. Plate and screw fixation of clavicular fractures could provide rigid fixation and rotational control. Proper implant positioning in surgical fixation is critical to prevent iatro...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618203/ https://www.ncbi.nlm.nih.gov/pubmed/36309726 http://dx.doi.org/10.1186/s12893-022-01813-7 |
_version_ | 1784820998509428736 |
---|---|
author | Chen, Wentao Wang, Baojun Liu, Zhenyu |
author_facet | Chen, Wentao Wang, Baojun Liu, Zhenyu |
author_sort | Chen, Wentao |
collection | PubMed |
description | BACKGROUND: Open reduction and internal fixation have been frequently applied for displaced midshaft clavicular fracture. Plate and screw fixation of clavicular fractures could provide rigid fixation and rotational control. Proper implant positioning in surgical fixation is critical to prevent iatrogenic complications. Fluoroscopy plays an important role in the intraoperative evaluation of implants. This study aimed to introduce a new fluoroscopic projection to evaluate the positioning of plates and screws. METHODS: Adult patients with a diagnosis of acute displaced midshaft clavicular fracture were included in this study. The slope angle of the midshaft clavicle was measured on sagittal reconstructions of preoperative computed tomography (CT) scans. The incidence of screw revision based on intraoperative standard posteroanterior (PA) and PA 25° cephalic skyline projections was compared. The interobserver agreement for the two projections was calculated. RESULTS: Twenty-nine patients with midshaft clavicular fractures were enrolled from January 2020 to June 2021. The PA 25° skyline projection could clearly display the tangential line of the plate and inferior border of the clavicle. The slope angle on the superior surface of the midshaft clavicle was 26.0 ± 5.8° (range: 18.5–38.3°). The incidence of screw revision using the PA projection (72.4%) was significantly different from that using the PA 25° skyline projection (34.5%) (P < 0.05). The concordance of the screw revision rate based on the standard PA and PA 25° skyline projections was strong, with kappa coefficients of 0.680 (95% CI: 0.394–0.968) and 0.776 (95% CI: 0.537–0.998). CONCLUSION: The PA 25° skyline projection corresponds to the slope angle of the midshaft clavicle. It can provide more accurate information regarding the proper screw length and be applied as a routine method for intraoperative evaluation. |
format | Online Article Text |
id | pubmed-9618203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-96182032022-10-31 A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection Chen, Wentao Wang, Baojun Liu, Zhenyu BMC Surg Research BACKGROUND: Open reduction and internal fixation have been frequently applied for displaced midshaft clavicular fracture. Plate and screw fixation of clavicular fractures could provide rigid fixation and rotational control. Proper implant positioning in surgical fixation is critical to prevent iatrogenic complications. Fluoroscopy plays an important role in the intraoperative evaluation of implants. This study aimed to introduce a new fluoroscopic projection to evaluate the positioning of plates and screws. METHODS: Adult patients with a diagnosis of acute displaced midshaft clavicular fracture were included in this study. The slope angle of the midshaft clavicle was measured on sagittal reconstructions of preoperative computed tomography (CT) scans. The incidence of screw revision based on intraoperative standard posteroanterior (PA) and PA 25° cephalic skyline projections was compared. The interobserver agreement for the two projections was calculated. RESULTS: Twenty-nine patients with midshaft clavicular fractures were enrolled from January 2020 to June 2021. The PA 25° skyline projection could clearly display the tangential line of the plate and inferior border of the clavicle. The slope angle on the superior surface of the midshaft clavicle was 26.0 ± 5.8° (range: 18.5–38.3°). The incidence of screw revision using the PA projection (72.4%) was significantly different from that using the PA 25° skyline projection (34.5%) (P < 0.05). The concordance of the screw revision rate based on the standard PA and PA 25° skyline projections was strong, with kappa coefficients of 0.680 (95% CI: 0.394–0.968) and 0.776 (95% CI: 0.537–0.998). CONCLUSION: The PA 25° skyline projection corresponds to the slope angle of the midshaft clavicle. It can provide more accurate information regarding the proper screw length and be applied as a routine method for intraoperative evaluation. BioMed Central 2022-10-29 /pmc/articles/PMC9618203/ /pubmed/36309726 http://dx.doi.org/10.1186/s12893-022-01813-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Chen, Wentao Wang, Baojun Liu, Zhenyu A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title | A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title_full | A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title_fullStr | A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title_full_unstemmed | A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title_short | A fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
title_sort | fluoroscopic view for midshaft clavicular fracture reduction and internal fixation: posteroanterior 25° skyline projection |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618203/ https://www.ncbi.nlm.nih.gov/pubmed/36309726 http://dx.doi.org/10.1186/s12893-022-01813-7 |
work_keys_str_mv | AT chenwentao afluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection AT wangbaojun afluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection AT liuzhenyu afluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection AT chenwentao fluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection AT wangbaojun fluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection AT liuzhenyu fluoroscopicviewformidshaftclavicularfracturereductionandinternalfixationposteroanterior25skylineprojection |