Cargando…

Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis

AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness i...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Hui, Wang, Wei, Shen, Qiuyue, Feng, Zhouqin, Zhang, Zhen, Lei, Haiyan, Yang, Xinyi, Liu, Jun, Lu, Bin, Shao, Jiaqing, Gu, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618671/
https://www.ncbi.nlm.nih.gov/pubmed/36325447
http://dx.doi.org/10.3389/fendo.2022.1014568
_version_ 1784821102786117632
author Zhou, Hui
Wang, Wei
Shen, Qiuyue
Feng, Zhouqin
Zhang, Zhen
Lei, Haiyan
Yang, Xinyi
Liu, Jun
Lu, Bin
Shao, Jiaqing
Gu, Ping
author_facet Zhou, Hui
Wang, Wei
Shen, Qiuyue
Feng, Zhouqin
Zhang, Zhen
Lei, Haiyan
Yang, Xinyi
Liu, Jun
Lu, Bin
Shao, Jiaqing
Gu, Ping
author_sort Zhou, Hui
collection PubMed
description AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness in type 2 diabetes. METHODS: Study participants included 469 hospitalized patients with type 2 diabetes and no history of serious cardiovascular disease who underwent CGM and BaPWV measurements. TIR of 3.9-10.0 mmol/L was evaluated with CGM. BaPWV was measured by non-invasive arteriosclerosis detector and high baPWV was defined as a mean baPWV≧1800m/s. The spearman correlation and the partial correlation analysis were applied to analyze the correlation between TIR and baPWV. The binary logistic regression was used to examine the independent association of TIR and high BaPWV. RESULTS: The presence of high baPWV was 32.2%. Compared with patients of low baPWV, those with high baPWV had significantly reduced TIR(P<0.001). With the increase of TIR tertiles, the prevalence of high BaPWV progressively decreased. Correlation analysis showed that TIR is inversely correlated with BaPWV. In a fully adjusted model controlling for traditional risk factor of CVD, TIR is associated with the presence of high BaPWV independent of HbA1c. CONCLUSION: TIR is correlated with BaPWV independent of HbA1c in patients with type 2 diabetes, confirming a link between TIR and arterial stiffness.
format Online
Article
Text
id pubmed-9618671
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-96186712022-11-01 Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis Zhou, Hui Wang, Wei Shen, Qiuyue Feng, Zhouqin Zhang, Zhen Lei, Haiyan Yang, Xinyi Liu, Jun Lu, Bin Shao, Jiaqing Gu, Ping Front Endocrinol (Lausanne) Endocrinology AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness in type 2 diabetes. METHODS: Study participants included 469 hospitalized patients with type 2 diabetes and no history of serious cardiovascular disease who underwent CGM and BaPWV measurements. TIR of 3.9-10.0 mmol/L was evaluated with CGM. BaPWV was measured by non-invasive arteriosclerosis detector and high baPWV was defined as a mean baPWV≧1800m/s. The spearman correlation and the partial correlation analysis were applied to analyze the correlation between TIR and baPWV. The binary logistic regression was used to examine the independent association of TIR and high BaPWV. RESULTS: The presence of high baPWV was 32.2%. Compared with patients of low baPWV, those with high baPWV had significantly reduced TIR(P<0.001). With the increase of TIR tertiles, the prevalence of high BaPWV progressively decreased. Correlation analysis showed that TIR is inversely correlated with BaPWV. In a fully adjusted model controlling for traditional risk factor of CVD, TIR is associated with the presence of high BaPWV independent of HbA1c. CONCLUSION: TIR is correlated with BaPWV independent of HbA1c in patients with type 2 diabetes, confirming a link between TIR and arterial stiffness. Frontiers Media S.A. 2022-10-17 /pmc/articles/PMC9618671/ /pubmed/36325447 http://dx.doi.org/10.3389/fendo.2022.1014568 Text en Copyright © 2022 Zhou, Wang, Shen, Feng, Zhang, Lei, Yang, Liu, Lu, Shao and Gu https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Endocrinology
Zhou, Hui
Wang, Wei
Shen, Qiuyue
Feng, Zhouqin
Zhang, Zhen
Lei, Haiyan
Yang, Xinyi
Liu, Jun
Lu, Bin
Shao, Jiaqing
Gu, Ping
Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title_full Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title_fullStr Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title_full_unstemmed Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title_short Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
title_sort time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: a retrospective single-center analysis
topic Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618671/
https://www.ncbi.nlm.nih.gov/pubmed/36325447
http://dx.doi.org/10.3389/fendo.2022.1014568
work_keys_str_mv AT zhouhui timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT wangwei timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT shenqiuyue timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT fengzhouqin timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT zhangzhen timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT leihaiyan timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT yangxinyi timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT liujun timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT lubin timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT shaojiaqing timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis
AT guping timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis