Cargando…
Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis
AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness i...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618671/ https://www.ncbi.nlm.nih.gov/pubmed/36325447 http://dx.doi.org/10.3389/fendo.2022.1014568 |
_version_ | 1784821102786117632 |
---|---|
author | Zhou, Hui Wang, Wei Shen, Qiuyue Feng, Zhouqin Zhang, Zhen Lei, Haiyan Yang, Xinyi Liu, Jun Lu, Bin Shao, Jiaqing Gu, Ping |
author_facet | Zhou, Hui Wang, Wei Shen, Qiuyue Feng, Zhouqin Zhang, Zhen Lei, Haiyan Yang, Xinyi Liu, Jun Lu, Bin Shao, Jiaqing Gu, Ping |
author_sort | Zhou, Hui |
collection | PubMed |
description | AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness in type 2 diabetes. METHODS: Study participants included 469 hospitalized patients with type 2 diabetes and no history of serious cardiovascular disease who underwent CGM and BaPWV measurements. TIR of 3.9-10.0 mmol/L was evaluated with CGM. BaPWV was measured by non-invasive arteriosclerosis detector and high baPWV was defined as a mean baPWV≧1800m/s. The spearman correlation and the partial correlation analysis were applied to analyze the correlation between TIR and baPWV. The binary logistic regression was used to examine the independent association of TIR and high BaPWV. RESULTS: The presence of high baPWV was 32.2%. Compared with patients of low baPWV, those with high baPWV had significantly reduced TIR(P<0.001). With the increase of TIR tertiles, the prevalence of high BaPWV progressively decreased. Correlation analysis showed that TIR is inversely correlated with BaPWV. In a fully adjusted model controlling for traditional risk factor of CVD, TIR is associated with the presence of high BaPWV independent of HbA1c. CONCLUSION: TIR is correlated with BaPWV independent of HbA1c in patients with type 2 diabetes, confirming a link between TIR and arterial stiffness. |
format | Online Article Text |
id | pubmed-9618671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-96186712022-11-01 Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis Zhou, Hui Wang, Wei Shen, Qiuyue Feng, Zhouqin Zhang, Zhen Lei, Haiyan Yang, Xinyi Liu, Jun Lu, Bin Shao, Jiaqing Gu, Ping Front Endocrinol (Lausanne) Endocrinology AIMS: The aim of this retrospective single-center is to research the relationship between time in range(TIR), an important novel metric of glycemic control, assessed with continuous glucose monitoring(CGM) and brachial-ankle pulse wave velocity(BaPWV), a unique index of systemic arterial stiffness in type 2 diabetes. METHODS: Study participants included 469 hospitalized patients with type 2 diabetes and no history of serious cardiovascular disease who underwent CGM and BaPWV measurements. TIR of 3.9-10.0 mmol/L was evaluated with CGM. BaPWV was measured by non-invasive arteriosclerosis detector and high baPWV was defined as a mean baPWV≧1800m/s. The spearman correlation and the partial correlation analysis were applied to analyze the correlation between TIR and baPWV. The binary logistic regression was used to examine the independent association of TIR and high BaPWV. RESULTS: The presence of high baPWV was 32.2%. Compared with patients of low baPWV, those with high baPWV had significantly reduced TIR(P<0.001). With the increase of TIR tertiles, the prevalence of high BaPWV progressively decreased. Correlation analysis showed that TIR is inversely correlated with BaPWV. In a fully adjusted model controlling for traditional risk factor of CVD, TIR is associated with the presence of high BaPWV independent of HbA1c. CONCLUSION: TIR is correlated with BaPWV independent of HbA1c in patients with type 2 diabetes, confirming a link between TIR and arterial stiffness. Frontiers Media S.A. 2022-10-17 /pmc/articles/PMC9618671/ /pubmed/36325447 http://dx.doi.org/10.3389/fendo.2022.1014568 Text en Copyright © 2022 Zhou, Wang, Shen, Feng, Zhang, Lei, Yang, Liu, Lu, Shao and Gu https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Endocrinology Zhou, Hui Wang, Wei Shen, Qiuyue Feng, Zhouqin Zhang, Zhen Lei, Haiyan Yang, Xinyi Liu, Jun Lu, Bin Shao, Jiaqing Gu, Ping Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title | Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title_full | Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title_fullStr | Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title_full_unstemmed | Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title_short | Time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: A retrospective single-center analysis |
title_sort | time in range, assessed with continuous glucose monitoring, is associated with brachial-ankle pulse wave velocity in type 2 diabetes: a retrospective single-center analysis |
topic | Endocrinology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618671/ https://www.ncbi.nlm.nih.gov/pubmed/36325447 http://dx.doi.org/10.3389/fendo.2022.1014568 |
work_keys_str_mv | AT zhouhui timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT wangwei timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT shenqiuyue timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT fengzhouqin timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT zhangzhen timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT leihaiyan timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT yangxinyi timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT liujun timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT lubin timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT shaojiaqing timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis AT guping timeinrangeassessedwithcontinuousglucosemonitoringisassociatedwithbrachialanklepulsewavevelocityintype2diabetesaretrospectivesinglecenteranalysis |