Cargando…

Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method

Sensitive and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), frequently performed using direct polymerase chain reaction (PCR), is essential for restricting the spread of coronavirus disease 2019 (COVID-19). However, studies evaluating accurate detection are stil...

Descripción completa

Detalles Bibliográficos
Autores principales: Deura, Chikaya, Nakayama, Kenji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9620949/
https://www.ncbi.nlm.nih.gov/pubmed/36417227
http://dx.doi.org/10.3390/epidemiologia2030023
_version_ 1784821432317902848
author Deura, Chikaya
Nakayama, Kenji
author_facet Deura, Chikaya
Nakayama, Kenji
author_sort Deura, Chikaya
collection PubMed
description Sensitive and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), frequently performed using direct polymerase chain reaction (PCR), is essential for restricting the spread of coronavirus disease 2019 (COVID-19). However, studies evaluating accurate detection are still required. This study evaluated the quantitativeness and sensitivity of the Ampdirect™ 2019-nCoV detection kit, a direct PCR method. Using saliva with or without Tris-buffered saline (TBS) dilution, linearity, and limits of the N1 and N2 regions of SARS-CoV-2 genomic RNA were assessed using EDX SARS-CoV-2 RNA standard dissolved in RNase-free water (RFW). Fluorescence intensities in non-diluted saliva were higher than those in TBS-diluted samples. Linear regression analysis of detected quantification cycle values and spiked standard RNA concentrations showed that the coefficient of determination of the N1 and N2 genes was 0.972 and 0.615 in RFW and 0.947 and 0.660 in saliva, respectively. N1- and N2-positive detection rates in saliva were 46% (6/13 tests) and 0% (0/12 tests) at one copy/reaction, respectively. These results indicate good quantitativeness and sensitivity for N1 but not for N2. Therefore, our findings reveal that the Ampdirect™ 2019-nCoV system, especially targeting the N1 gene, enables rapid and convenient quantification of SARS-CoV-2 RNA in saliva at one copy/reaction.
format Online
Article
Text
id pubmed-9620949
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96209492022-11-18 Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method Deura, Chikaya Nakayama, Kenji Epidemiologia (Basel) Brief Report Sensitive and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), frequently performed using direct polymerase chain reaction (PCR), is essential for restricting the spread of coronavirus disease 2019 (COVID-19). However, studies evaluating accurate detection are still required. This study evaluated the quantitativeness and sensitivity of the Ampdirect™ 2019-nCoV detection kit, a direct PCR method. Using saliva with or without Tris-buffered saline (TBS) dilution, linearity, and limits of the N1 and N2 regions of SARS-CoV-2 genomic RNA were assessed using EDX SARS-CoV-2 RNA standard dissolved in RNase-free water (RFW). Fluorescence intensities in non-diluted saliva were higher than those in TBS-diluted samples. Linear regression analysis of detected quantification cycle values and spiked standard RNA concentrations showed that the coefficient of determination of the N1 and N2 genes was 0.972 and 0.615 in RFW and 0.947 and 0.660 in saliva, respectively. N1- and N2-positive detection rates in saliva were 46% (6/13 tests) and 0% (0/12 tests) at one copy/reaction, respectively. These results indicate good quantitativeness and sensitivity for N1 but not for N2. Therefore, our findings reveal that the Ampdirect™ 2019-nCoV system, especially targeting the N1 gene, enables rapid and convenient quantification of SARS-CoV-2 RNA in saliva at one copy/reaction. MDPI 2021-07-28 /pmc/articles/PMC9620949/ /pubmed/36417227 http://dx.doi.org/10.3390/epidemiologia2030023 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Brief Report
Deura, Chikaya
Nakayama, Kenji
Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title_full Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title_fullStr Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title_full_unstemmed Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title_short Rapid and Convenient Quantitative Analysis of SARS-CoV-2 RNA in Serous Saliva with a Direct PCR Method
title_sort rapid and convenient quantitative analysis of sars-cov-2 rna in serous saliva with a direct pcr method
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9620949/
https://www.ncbi.nlm.nih.gov/pubmed/36417227
http://dx.doi.org/10.3390/epidemiologia2030023
work_keys_str_mv AT deurachikaya rapidandconvenientquantitativeanalysisofsarscov2rnainseroussalivawithadirectpcrmethod
AT nakayamakenji rapidandconvenientquantitativeanalysisofsarscov2rnainseroussalivawithadirectpcrmethod