Cargando…
Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study
BACKGROUND: Though ultrasound-guided percutaneous lung needle biopsy (US-PLNB) is a first-line small biopsy method for peripheral lung lesions, quality of cellularity in specimens obtained via US-PLNB is uncertain. This study investigated the accuracy, sensitivity, and cellularity of US-PLNB. It exa...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622440/ https://www.ncbi.nlm.nih.gov/pubmed/36330190 http://dx.doi.org/10.21037/qims-22-119 |
_version_ | 1784821768661237760 |
---|---|
author | Zhou, Dazhi Zhang, Yuxin Chen, Wuxi Jiang, Juhong Chen, Yanbin Zhou, Xinghua Tang, Qing |
author_facet | Zhou, Dazhi Zhang, Yuxin Chen, Wuxi Jiang, Juhong Chen, Yanbin Zhou, Xinghua Tang, Qing |
author_sort | Zhou, Dazhi |
collection | PubMed |
description | BACKGROUND: Though ultrasound-guided percutaneous lung needle biopsy (US-PLNB) is a first-line small biopsy method for peripheral lung lesions, quality of cellularity in specimens obtained via US-PLNB is uncertain. This study investigated the accuracy, sensitivity, and cellularity of US-PLNB. It examined the ability of contrast-enhanced ultrasound (CEUS) to improve the effectiveness of US-PLNB. METHODS: We retrospectively analyzed all data of patients with subpleural lung lesions who underwent US-PLNB. The cellularity of US-PLNB from malignant lesions included the tumor cell number and proportion. The definition of high-quality cellularity (HQC) was concurrently achieving a tumor cell number ≥400 and a proportion ≥20%. The sensitivity, the actual numbers of tumor cell number/proportion, and the rate of HQC were calculated and compared between the CEUS and non-enhanced US groups after propensity score matching (PSM) with subgroup analyses by lesion size (small lesion ≤30 mm and large lesion >30 mm). RESULTS: A total of 345 patients undergoing 345 US-PLNBs were evaluated, with 3.7±1.1 of punctures on average. There were 201 malignant and 144 benign lesions with a mean size of 43.8±24.1 mm. Among the 201 malignant lesions, 124 cases underwent CEUS and 77 underwent non-enhanced US. The quantity of tumor cells, the proportion of tumor cells, and the rate of HQC in 201 cases of US-PLNB from malignant lesions were 2,862.1±2,288.0, 44.6%±24.5%, and 82.1% [95% confidence interval (CI): 76.6% to 87.1%], respectively. The quantity of tumor cells, the proportion of tumor cells, and rate of HQC were significantly higher in the CEUS group than that in the non-enhanced US group, both in the analysis of overall malignant lesions and in large malignant lesions (all P<0.05). CONCLUSIONS: The US-PLNB has high sensitivity and thereby obtains HQC samples for subpleural lung malignant lesions. The CEUS helps improve the rate of HQC and tissue cellularity of lung malignancies. |
format | Online Article Text |
id | pubmed-9622440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-96224402022-11-02 Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study Zhou, Dazhi Zhang, Yuxin Chen, Wuxi Jiang, Juhong Chen, Yanbin Zhou, Xinghua Tang, Qing Quant Imaging Med Surg Original Article BACKGROUND: Though ultrasound-guided percutaneous lung needle biopsy (US-PLNB) is a first-line small biopsy method for peripheral lung lesions, quality of cellularity in specimens obtained via US-PLNB is uncertain. This study investigated the accuracy, sensitivity, and cellularity of US-PLNB. It examined the ability of contrast-enhanced ultrasound (CEUS) to improve the effectiveness of US-PLNB. METHODS: We retrospectively analyzed all data of patients with subpleural lung lesions who underwent US-PLNB. The cellularity of US-PLNB from malignant lesions included the tumor cell number and proportion. The definition of high-quality cellularity (HQC) was concurrently achieving a tumor cell number ≥400 and a proportion ≥20%. The sensitivity, the actual numbers of tumor cell number/proportion, and the rate of HQC were calculated and compared between the CEUS and non-enhanced US groups after propensity score matching (PSM) with subgroup analyses by lesion size (small lesion ≤30 mm and large lesion >30 mm). RESULTS: A total of 345 patients undergoing 345 US-PLNBs were evaluated, with 3.7±1.1 of punctures on average. There were 201 malignant and 144 benign lesions with a mean size of 43.8±24.1 mm. Among the 201 malignant lesions, 124 cases underwent CEUS and 77 underwent non-enhanced US. The quantity of tumor cells, the proportion of tumor cells, and the rate of HQC in 201 cases of US-PLNB from malignant lesions were 2,862.1±2,288.0, 44.6%±24.5%, and 82.1% [95% confidence interval (CI): 76.6% to 87.1%], respectively. The quantity of tumor cells, the proportion of tumor cells, and rate of HQC were significantly higher in the CEUS group than that in the non-enhanced US group, both in the analysis of overall malignant lesions and in large malignant lesions (all P<0.05). CONCLUSIONS: The US-PLNB has high sensitivity and thereby obtains HQC samples for subpleural lung malignant lesions. The CEUS helps improve the rate of HQC and tissue cellularity of lung malignancies. AME Publishing Company 2022-11 /pmc/articles/PMC9622440/ /pubmed/36330190 http://dx.doi.org/10.21037/qims-22-119 Text en 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Zhou, Dazhi Zhang, Yuxin Chen, Wuxi Jiang, Juhong Chen, Yanbin Zhou, Xinghua Tang, Qing Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title | Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title_full | Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title_fullStr | Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title_full_unstemmed | Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title_short | Enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
title_sort | enhanced ultrasound-guided versus non-enhanced ultrasound-guided percutaneous needle biopsy in tissue cellularity of lung malignancies: a propensity score matched study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622440/ https://www.ncbi.nlm.nih.gov/pubmed/36330190 http://dx.doi.org/10.21037/qims-22-119 |
work_keys_str_mv | AT zhoudazhi enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT zhangyuxin enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT chenwuxi enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT jiangjuhong enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT chenyanbin enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT zhouxinghua enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy AT tangqing enhancedultrasoundguidedversusnonenhancedultrasoundguidedpercutaneousneedlebiopsyintissuecellularityoflungmalignanciesapropensityscorematchedstudy |