Cargando…

Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report

Surgery is the treatment of choice for esophageal cancer. Since the 1990s, minimally invasive esophagectomy (MIE) has been developed using videoscope. Although MIE lowers mortality by reducing postoperative complications, the risk of carbon dioxide (CO(2)) insufflation related complications still ex...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jeong Eun, Kim, Myeong Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622717/
https://www.ncbi.nlm.nih.gov/pubmed/36316887
http://dx.doi.org/10.1097/MD.0000000000031420
_version_ 1784821835252105216
author Lee, Jeong Eun
Kim, Myeong Jin
author_facet Lee, Jeong Eun
Kim, Myeong Jin
author_sort Lee, Jeong Eun
collection PubMed
description Surgery is the treatment of choice for esophageal cancer. Since the 1990s, minimally invasive esophagectomy (MIE) has been developed using videoscope. Although MIE lowers mortality by reducing postoperative complications, the risk of carbon dioxide (CO(2)) insufflation related complications still exists. PATIENT CONCERNS: A 56-years-old male patient underwent elective MIE. The patient (body mass index, 15 kg/m(2)) had well-controlled hypertension, cardiomegaly, and severe emphysematous lungs. He had iatrogenic pneumothorax during central venous catheterization 3 weeks prior; however, the pneumothorax was resolved before surgery. DIAGNOSIS: During thoracoscopic surgery, respiratory acidosis was not corrected despite rapid respiratory rate and positive end-expiratory pressure. Intrathoracic CO(2) pressure was lowered from 12 to 8 mm Hg, and laparoscopic surgery was performed through the diaphragm in the reverse Trendelenburg position. In 15 minutes at this position, pulseless electrical activity with respiratory failure and high peak inspiratory pressure developed. INTERVENTIONS: CO(2) insufflation was stopped and drained as soon as hypotension developed. The patient was placed in the supine neutral position, and cardiopulmonary circulation was restored without further treatment. OUTCOMES: After the pneumomediastinum event, surgery was successfully performed. Respiratory acidosis due to CO(2) insufflation was not corrected during surgery and the patient was transferred to intensive care unit without extubation. After 14 days, the patient was discharged without cardiopulmonary complications. However, the patient expired 2 years later due to cardiovascular disease. LESSONS: In MIE, there is always a risk of catastrophic tension pneumomediastinum along with intravascular volume depletion, surgical position, and ventilatory strategy depending on the surgical characteristics.
format Online
Article
Text
id pubmed-9622717
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-96227172022-11-03 Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report Lee, Jeong Eun Kim, Myeong Jin Medicine (Baltimore) 3300 Surgery is the treatment of choice for esophageal cancer. Since the 1990s, minimally invasive esophagectomy (MIE) has been developed using videoscope. Although MIE lowers mortality by reducing postoperative complications, the risk of carbon dioxide (CO(2)) insufflation related complications still exists. PATIENT CONCERNS: A 56-years-old male patient underwent elective MIE. The patient (body mass index, 15 kg/m(2)) had well-controlled hypertension, cardiomegaly, and severe emphysematous lungs. He had iatrogenic pneumothorax during central venous catheterization 3 weeks prior; however, the pneumothorax was resolved before surgery. DIAGNOSIS: During thoracoscopic surgery, respiratory acidosis was not corrected despite rapid respiratory rate and positive end-expiratory pressure. Intrathoracic CO(2) pressure was lowered from 12 to 8 mm Hg, and laparoscopic surgery was performed through the diaphragm in the reverse Trendelenburg position. In 15 minutes at this position, pulseless electrical activity with respiratory failure and high peak inspiratory pressure developed. INTERVENTIONS: CO(2) insufflation was stopped and drained as soon as hypotension developed. The patient was placed in the supine neutral position, and cardiopulmonary circulation was restored without further treatment. OUTCOMES: After the pneumomediastinum event, surgery was successfully performed. Respiratory acidosis due to CO(2) insufflation was not corrected during surgery and the patient was transferred to intensive care unit without extubation. After 14 days, the patient was discharged without cardiopulmonary complications. However, the patient expired 2 years later due to cardiovascular disease. LESSONS: In MIE, there is always a risk of catastrophic tension pneumomediastinum along with intravascular volume depletion, surgical position, and ventilatory strategy depending on the surgical characteristics. Lippincott Williams & Wilkins 2022-10-28 /pmc/articles/PMC9622717/ /pubmed/36316887 http://dx.doi.org/10.1097/MD.0000000000031420 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 3300
Lee, Jeong Eun
Kim, Myeong Jin
Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title_full Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title_fullStr Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title_full_unstemmed Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title_short Hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: A case report
title_sort hemodynamic derangement associated with tension pneumomediastinum during minimally invasive esophagectomy: a case report
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622717/
https://www.ncbi.nlm.nih.gov/pubmed/36316887
http://dx.doi.org/10.1097/MD.0000000000031420
work_keys_str_mv AT leejeongeun hemodynamicderangementassociatedwithtensionpneumomediastinumduringminimallyinvasiveesophagectomyacasereport
AT kimmyeongjin hemodynamicderangementassociatedwithtensionpneumomediastinumduringminimallyinvasiveesophagectomyacasereport