Cargando…
Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula
OBJECTIVE: To evaluate the accuracy of differential subsampling with cartesian ordering (DISCO) in comparison to time of flight (TOF) in detecting dural arteriovenous fistulas (DAVF), cerebral venous thrombosis (CVT) and hemodynamics. METHODS: Sixty-two cases (24 female; aged 14–75; mean age, 51.3 y...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622796/ https://www.ncbi.nlm.nih.gov/pubmed/36330430 http://dx.doi.org/10.3389/fneur.2022.1020749 |
_version_ | 1784821854179950592 |
---|---|
author | Chen, Xi Ge, Liang Wan, Hailinlin Huang, Lei Jiang, Yeqing Lu, Gang Wang, Jing Zhang, Xiaolong |
author_facet | Chen, Xi Ge, Liang Wan, Hailinlin Huang, Lei Jiang, Yeqing Lu, Gang Wang, Jing Zhang, Xiaolong |
author_sort | Chen, Xi |
collection | PubMed |
description | OBJECTIVE: To evaluate the accuracy of differential subsampling with cartesian ordering (DISCO) in comparison to time of flight (TOF) in detecting dural arteriovenous fistulas (DAVF), cerebral venous thrombosis (CVT) and hemodynamics. METHODS: Sixty-two cases (24 female; aged 14–75; mean age, 51.3 years) were included in our study, with 42 positive and 20 negative cases via Digital Subtraction Angiography (DSA). Two neuroradiologists independently evaluated the DISCO and TOF. The sensitivity, specificity, and accuracy of the DISCO and TOF-MRA were individually calculated using DSA as the gold standard. Inter-observer reliability was assessed by using a weighted Cohen's kappa (κ) test; P < 0.05 was set as the threshold for statistical significance. RESULTS: Diagnostic sensitivities of DISCO and TOF for DAVF were 92.86 and 64.29%; specificities were 95.0% and 95.0%; while accuracies were 93.55 and 74.19% respectively. For detected CVT, sensitivities of DISCO and TOF were 100 and 92.31%; specificities were 96.55 and 93.10%; with accuracies 97.62 and 92.86% respectively. In hemodynamic analysis, sensitivity of DISCO for reflux was 95.45%; with a specificity of 95.0%; and accuracy 95.24%. The inter-observer kappa values were 0.857 for DISCO (P < 0.001). CONCLUSION: DISCO showed a high degree of sensitivity and specificity, suggesting its effectiveness in detecting DAVF with or without CVT. Intracranial hemodynamics can be identified using DISCO in DAVF patients, providing accurate evaluation of cerebral blood flow dynamics during the pre-treatment phase. |
format | Online Article Text |
id | pubmed-9622796 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-96227962022-11-02 Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula Chen, Xi Ge, Liang Wan, Hailinlin Huang, Lei Jiang, Yeqing Lu, Gang Wang, Jing Zhang, Xiaolong Front Neurol Neurology OBJECTIVE: To evaluate the accuracy of differential subsampling with cartesian ordering (DISCO) in comparison to time of flight (TOF) in detecting dural arteriovenous fistulas (DAVF), cerebral venous thrombosis (CVT) and hemodynamics. METHODS: Sixty-two cases (24 female; aged 14–75; mean age, 51.3 years) were included in our study, with 42 positive and 20 negative cases via Digital Subtraction Angiography (DSA). Two neuroradiologists independently evaluated the DISCO and TOF. The sensitivity, specificity, and accuracy of the DISCO and TOF-MRA were individually calculated using DSA as the gold standard. Inter-observer reliability was assessed by using a weighted Cohen's kappa (κ) test; P < 0.05 was set as the threshold for statistical significance. RESULTS: Diagnostic sensitivities of DISCO and TOF for DAVF were 92.86 and 64.29%; specificities were 95.0% and 95.0%; while accuracies were 93.55 and 74.19% respectively. For detected CVT, sensitivities of DISCO and TOF were 100 and 92.31%; specificities were 96.55 and 93.10%; with accuracies 97.62 and 92.86% respectively. In hemodynamic analysis, sensitivity of DISCO for reflux was 95.45%; with a specificity of 95.0%; and accuracy 95.24%. The inter-observer kappa values were 0.857 for DISCO (P < 0.001). CONCLUSION: DISCO showed a high degree of sensitivity and specificity, suggesting its effectiveness in detecting DAVF with or without CVT. Intracranial hemodynamics can be identified using DISCO in DAVF patients, providing accurate evaluation of cerebral blood flow dynamics during the pre-treatment phase. Frontiers Media S.A. 2022-10-18 /pmc/articles/PMC9622796/ /pubmed/36330430 http://dx.doi.org/10.3389/fneur.2022.1020749 Text en Copyright © 2022 Chen, Ge, Wan, Huang, Jiang, Lu, Wang and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Chen, Xi Ge, Liang Wan, Hailinlin Huang, Lei Jiang, Yeqing Lu, Gang Wang, Jing Zhang, Xiaolong Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title | Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title_full | Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title_fullStr | Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title_full_unstemmed | Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title_short | Differential subsampling with cartesian ordering: A high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
title_sort | differential subsampling with cartesian ordering: a high spatial-temporal resolution dixon imaging sequence for assessment of dural arteriovenous fistula |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9622796/ https://www.ncbi.nlm.nih.gov/pubmed/36330430 http://dx.doi.org/10.3389/fneur.2022.1020749 |
work_keys_str_mv | AT chenxi differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT geliang differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT wanhailinlin differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT huanglei differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT jiangyeqing differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT lugang differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT wangjing differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula AT zhangxiaolong differentialsubsamplingwithcartesianorderingahighspatialtemporalresolutiondixonimagingsequenceforassessmentofduralarteriovenousfistula |