Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623023/ https://www.ncbi.nlm.nih.gov/pubmed/36330366 http://dx.doi.org/10.3389/fped.2022.976826 |
_version_ | 1784821900448366592 |
---|---|
author | Liu, Xuexiu Tao, Xiaojun Xu, Ye Zhang, Xianhong Chen, Yanhan Wu, Liping |
author_facet | Liu, Xuexiu Tao, Xiaojun Xu, Ye Zhang, Xianhong Chen, Yanhan Wu, Liping |
author_sort | Liu, Xuexiu |
collection | PubMed |
description | OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control clinical trial. A consecutive series of 181 neonate patients were finally enrolled for PICC placement. CR, followed by US, was used to evaluate and readjust the sites of catheter tips. The imaging capability for PICC key structures, fluctuation of the measured data, measurement of tip-to-atrium distance, operation time, infants' body temperature changes, and direct expenses of the two imaging modalities were obtained and compared. RESULTS: (1) Comparison in viewing PICC key structures: the display rate of catheter tip, SVC-and-right-atrium junction, IVC-and-right-atrium junction and tip-to-atrium distance is 99.47%, 100%, 100% and 99.47% for US and 100%, 98.42%, 97.37% and 95.79% for CR, respectively. (2) Fluctuation of the measured data by US and CR: the tip-to-atrium distance measured by US is 0.631 (0.435–0.820) cm, and that measured by CR is 0.593 (0.210–0.825) cm. US showed a narrower range of datum variance. (3) Consistency between US and CR: for consistency analysis, the Kappa coefficient (κ) was 0.843 (P < 0.05), showing their favorable consistency. (4) Comparison of operation time and infants' body temperature drop: for a CR exam, the time period taken was significantly longer than that of US (59.7 ± 26.33 vs. 79.6 ± 28.06, P < 0.001); and CR operations caused a significant babies' body temperature drop compared to US (0.14 ± 0.11 vs. 0.34 ± 0.19, P < 0.001). (5) Comparison of the direct expenses: the total cost for CR positioning was significantly higher than that for US (¥153.99 vs. ¥143, P = 0.026). CONCLUSION: US exhibited superior traits to CR in the positioning of PICC tip. It could be promising for routine use in NICU. |
format | Online Article Text |
id | pubmed-9623023 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-96230232022-11-02 Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study Liu, Xuexiu Tao, Xiaojun Xu, Ye Zhang, Xianhong Chen, Yanhan Wu, Liping Front Pediatr Pediatrics OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control clinical trial. A consecutive series of 181 neonate patients were finally enrolled for PICC placement. CR, followed by US, was used to evaluate and readjust the sites of catheter tips. The imaging capability for PICC key structures, fluctuation of the measured data, measurement of tip-to-atrium distance, operation time, infants' body temperature changes, and direct expenses of the two imaging modalities were obtained and compared. RESULTS: (1) Comparison in viewing PICC key structures: the display rate of catheter tip, SVC-and-right-atrium junction, IVC-and-right-atrium junction and tip-to-atrium distance is 99.47%, 100%, 100% and 99.47% for US and 100%, 98.42%, 97.37% and 95.79% for CR, respectively. (2) Fluctuation of the measured data by US and CR: the tip-to-atrium distance measured by US is 0.631 (0.435–0.820) cm, and that measured by CR is 0.593 (0.210–0.825) cm. US showed a narrower range of datum variance. (3) Consistency between US and CR: for consistency analysis, the Kappa coefficient (κ) was 0.843 (P < 0.05), showing their favorable consistency. (4) Comparison of operation time and infants' body temperature drop: for a CR exam, the time period taken was significantly longer than that of US (59.7 ± 26.33 vs. 79.6 ± 28.06, P < 0.001); and CR operations caused a significant babies' body temperature drop compared to US (0.14 ± 0.11 vs. 0.34 ± 0.19, P < 0.001). (5) Comparison of the direct expenses: the total cost for CR positioning was significantly higher than that for US (¥153.99 vs. ¥143, P = 0.026). CONCLUSION: US exhibited superior traits to CR in the positioning of PICC tip. It could be promising for routine use in NICU. Frontiers Media S.A. 2022-10-18 /pmc/articles/PMC9623023/ /pubmed/36330366 http://dx.doi.org/10.3389/fped.2022.976826 Text en © 2022 Liu, Tao, Xu, Zhang, Chen and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pediatrics Liu, Xuexiu Tao, Xiaojun Xu, Ye Zhang, Xianhong Chen, Yanhan Wu, Liping Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title | Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title_full | Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title_fullStr | Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title_full_unstemmed | Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title_short | Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study |
title_sort | comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: a before and after self-control study |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623023/ https://www.ncbi.nlm.nih.gov/pubmed/36330366 http://dx.doi.org/10.3389/fped.2022.976826 |
work_keys_str_mv | AT liuxuexiu comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy AT taoxiaojun comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy AT xuye comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy AT zhangxianhong comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy AT chenyanhan comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy AT wuliping comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy |