Cargando…

Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study

OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control c...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Xuexiu, Tao, Xiaojun, Xu, Ye, Zhang, Xianhong, Chen, Yanhan, Wu, Liping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623023/
https://www.ncbi.nlm.nih.gov/pubmed/36330366
http://dx.doi.org/10.3389/fped.2022.976826
_version_ 1784821900448366592
author Liu, Xuexiu
Tao, Xiaojun
Xu, Ye
Zhang, Xianhong
Chen, Yanhan
Wu, Liping
author_facet Liu, Xuexiu
Tao, Xiaojun
Xu, Ye
Zhang, Xianhong
Chen, Yanhan
Wu, Liping
author_sort Liu, Xuexiu
collection PubMed
description OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control clinical trial. A consecutive series of 181 neonate patients were finally enrolled for PICC placement. CR, followed by US, was used to evaluate and readjust the sites of catheter tips. The imaging capability for PICC key structures, fluctuation of the measured data, measurement of tip-to-atrium distance, operation time, infants' body temperature changes, and direct expenses of the two imaging modalities were obtained and compared. RESULTS: (1) Comparison in viewing PICC key structures: the display rate of catheter tip, SVC-and-right-atrium junction, IVC-and-right-atrium junction and tip-to-atrium distance is 99.47%, 100%, 100% and 99.47% for US and 100%, 98.42%, 97.37% and 95.79% for CR, respectively. (2) Fluctuation of the measured data by US and CR: the tip-to-atrium distance measured by US is 0.631 (0.435–0.820) cm, and that measured by CR is 0.593 (0.210–0.825) cm. US showed a narrower range of datum variance. (3) Consistency between US and CR: for consistency analysis, the Kappa coefficient (κ) was 0.843 (P < 0.05), showing their favorable consistency. (4) Comparison of operation time and infants' body temperature drop: for a CR exam, the time period taken was significantly longer than that of US (59.7 ± 26.33 vs. 79.6 ± 28.06, P < 0.001); and CR operations caused a significant babies' body temperature drop compared to US (0.14 ± 0.11 vs. 0.34 ± 0.19, P < 0.001). (5) Comparison of the direct expenses: the total cost for CR positioning was significantly higher than that for US (¥153.99 vs. ¥143, P = 0.026). CONCLUSION: US exhibited superior traits to CR in the positioning of PICC tip. It could be promising for routine use in NICU.
format Online
Article
Text
id pubmed-9623023
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-96230232022-11-02 Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study Liu, Xuexiu Tao, Xiaojun Xu, Ye Zhang, Xianhong Chen, Yanhan Wu, Liping Front Pediatr Pediatrics OBJECTIVE: This study aimed to compare the applications of bedside ultrasonography (US) and bedside chest radiography (CR) in positioning peripherally inserted central venous catheter (PICC) at Neonatal Intensive Care Units (NICUs). METHODS: The study is a prospective before and after self-control clinical trial. A consecutive series of 181 neonate patients were finally enrolled for PICC placement. CR, followed by US, was used to evaluate and readjust the sites of catheter tips. The imaging capability for PICC key structures, fluctuation of the measured data, measurement of tip-to-atrium distance, operation time, infants' body temperature changes, and direct expenses of the two imaging modalities were obtained and compared. RESULTS: (1) Comparison in viewing PICC key structures: the display rate of catheter tip, SVC-and-right-atrium junction, IVC-and-right-atrium junction and tip-to-atrium distance is 99.47%, 100%, 100% and 99.47% for US and 100%, 98.42%, 97.37% and 95.79% for CR, respectively. (2) Fluctuation of the measured data by US and CR: the tip-to-atrium distance measured by US is 0.631 (0.435–0.820) cm, and that measured by CR is 0.593 (0.210–0.825) cm. US showed a narrower range of datum variance. (3) Consistency between US and CR: for consistency analysis, the Kappa coefficient (κ) was 0.843 (P < 0.05), showing their favorable consistency. (4) Comparison of operation time and infants' body temperature drop: for a CR exam, the time period taken was significantly longer than that of US (59.7 ± 26.33 vs. 79.6 ± 28.06, P < 0.001); and CR operations caused a significant babies' body temperature drop compared to US (0.14 ± 0.11 vs. 0.34 ± 0.19, P < 0.001). (5) Comparison of the direct expenses: the total cost for CR positioning was significantly higher than that for US (¥153.99 vs. ¥143, P = 0.026). CONCLUSION: US exhibited superior traits to CR in the positioning of PICC tip. It could be promising for routine use in NICU. Frontiers Media S.A. 2022-10-18 /pmc/articles/PMC9623023/ /pubmed/36330366 http://dx.doi.org/10.3389/fped.2022.976826 Text en © 2022 Liu, Tao, Xu, Zhang, Chen and Wu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Liu, Xuexiu
Tao, Xiaojun
Xu, Ye
Zhang, Xianhong
Chen, Yanhan
Wu, Liping
Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title_full Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title_fullStr Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title_full_unstemmed Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title_short Comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: A before and after self-control study
title_sort comparison of bedside ultrasonography and bedside chest radiography in neonatal peripherally inserted central catheters: a before and after self-control study
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623023/
https://www.ncbi.nlm.nih.gov/pubmed/36330366
http://dx.doi.org/10.3389/fped.2022.976826
work_keys_str_mv AT liuxuexiu comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy
AT taoxiaojun comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy
AT xuye comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy
AT zhangxianhong comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy
AT chenyanhan comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy
AT wuliping comparisonofbedsideultrasonographyandbedsidechestradiographyinneonatalperipherallyinsertedcentralcathetersabeforeandafterselfcontrolstudy