Cargando…

On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics

[Image: see text] A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this...

Descripción completa

Detalles Bibliográficos
Autores principales: Gordón, José, Arruza, Luis, Ibáñez, María Dolores, Moreno-Guzmán, María, López, Miguel Ángel, Escarpa, Alberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623581/
https://www.ncbi.nlm.nih.gov/pubmed/36198198
http://dx.doi.org/10.1021/acssensors.2c01635
_version_ 1784822031984885760
author Gordón, José
Arruza, Luis
Ibáñez, María Dolores
Moreno-Guzmán, María
López, Miguel Ángel
Escarpa, Alberto
author_facet Gordón, José
Arruza, Luis
Ibáñez, María Dolores
Moreno-Guzmán, María
López, Miguel Ángel
Escarpa, Alberto
author_sort Gordón, José
collection PubMed
description [Image: see text] A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients, IL-6 has demonstrated good sensitivity and specificity for the diagnosis of sepsis, both for early and late onset sepsis. The approach was based on the adsorption of the aptamer for IL-6 tagged with 6-FAM as a fluorescent label (Apt(IL-6), λ(em) = 520 nm) on the graphene oxide external layer (MM(GO)–Apt(IL-6)) inducing fluorescence quenching (OFF state) and a subsequent on-the-move affinity recognition of IL-6 from Apt(IL-6) (IL-6–Apt(IL-6) complex) recovering the fluorescence (ON state). An aptamer against IL-6 was selected and developed by the systematic evolution of ligands by exponential enrichment technology. This approach displayed a suitable linear range of 0.07–1000 pg mL(–1) (r = 0.995) covering the cut-off and clinical practice levels, allowing direct determination without any dilution and simplifying the analysis as well as exhibiting an excellent sensitivity (LOD = 0.02 pg mL(–1)) in ultralow volumes of diagnostic clinical samples (2 μL). A high agreement between IL-6 levels obtained from our MM-based approach and the method used by the Hospital was obtained (relative error < 3%). The MM-based aptassay is competitive in comparison with that of the Hospital, in terms of a significant reduction of the sample volume (15 times less) and enhanced sensitivity, employing similar analysis times. These results position MM technology with enough potential to achieve high sensitivities in low sample volumes, opening new avenues in diagnosis based on low sample volumes.
format Online
Article
Text
id pubmed-9623581
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-96235812022-11-02 On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics Gordón, José Arruza, Luis Ibáñez, María Dolores Moreno-Guzmán, María López, Miguel Ángel Escarpa, Alberto ACS Sens [Image: see text] A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients, IL-6 has demonstrated good sensitivity and specificity for the diagnosis of sepsis, both for early and late onset sepsis. The approach was based on the adsorption of the aptamer for IL-6 tagged with 6-FAM as a fluorescent label (Apt(IL-6), λ(em) = 520 nm) on the graphene oxide external layer (MM(GO)–Apt(IL-6)) inducing fluorescence quenching (OFF state) and a subsequent on-the-move affinity recognition of IL-6 from Apt(IL-6) (IL-6–Apt(IL-6) complex) recovering the fluorescence (ON state). An aptamer against IL-6 was selected and developed by the systematic evolution of ligands by exponential enrichment technology. This approach displayed a suitable linear range of 0.07–1000 pg mL(–1) (r = 0.995) covering the cut-off and clinical practice levels, allowing direct determination without any dilution and simplifying the analysis as well as exhibiting an excellent sensitivity (LOD = 0.02 pg mL(–1)) in ultralow volumes of diagnostic clinical samples (2 μL). A high agreement between IL-6 levels obtained from our MM-based approach and the method used by the Hospital was obtained (relative error < 3%). The MM-based aptassay is competitive in comparison with that of the Hospital, in terms of a significant reduction of the sample volume (15 times less) and enhanced sensitivity, employing similar analysis times. These results position MM technology with enough potential to achieve high sensitivities in low sample volumes, opening new avenues in diagnosis based on low sample volumes. American Chemical Society 2022-10-05 2022-10-28 /pmc/articles/PMC9623581/ /pubmed/36198198 http://dx.doi.org/10.1021/acssensors.2c01635 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Gordón, José
Arruza, Luis
Ibáñez, María Dolores
Moreno-Guzmán, María
López, Miguel Ángel
Escarpa, Alberto
On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title_full On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title_fullStr On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title_full_unstemmed On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title_short On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics
title_sort on the move-sensitive fluorescent aptassay on board catalytic micromotors for the determination of interleukin-6 in ultra-low serum volumes for neonatal sepsis diagnostics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623581/
https://www.ncbi.nlm.nih.gov/pubmed/36198198
http://dx.doi.org/10.1021/acssensors.2c01635
work_keys_str_mv AT gordonjose onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics
AT arruzaluis onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics
AT ibanezmariadolores onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics
AT morenoguzmanmaria onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics
AT lopezmiguelangel onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics
AT escarpaalberto onthemovesensitivefluorescentaptassayonboardcatalyticmicromotorsforthedeterminationofinterleukin6inultralowserumvolumesforneonatalsepsisdiagnostics