Evaluation of an infrared thermography camera for measuring body temperature in dairy calves

The objective of this diagnostic accuracy study was to validate an infrared thermography (IRT) camera and its software (FLIR One, FLIR, Global) for accuracy and precision for ocular temperature readings to serve as a proxy for rectal temperature in commercially housed calves. A total of 318 male Hol...

Descripción completa

Detalles Bibliográficos
Autores principales: Cantor, M.C., Goetz, H.M., Beattie, K., Renaud, D.L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623779/
https://www.ncbi.nlm.nih.gov/pubmed/36340910
http://dx.doi.org/10.3168/jdsc.2022-0227
_version_ 1784822081829994496
author Cantor, M.C.
Goetz, H.M.
Beattie, K.
Renaud, D.L.
author_facet Cantor, M.C.
Goetz, H.M.
Beattie, K.
Renaud, D.L.
author_sort Cantor, M.C.
collection PubMed
description The objective of this diagnostic accuracy study was to validate an infrared thermography (IRT) camera and its software (FLIR One, FLIR, Global) for accuracy and precision for ocular temperature readings to serve as a proxy for rectal temperature in commercially housed calves. A total of 318 male Holstein calves were enrolled into this study from the day of arrival to a calf rearing facility until 14 d later. Researchers took an ocular temperature reading using an IRT camera, and a rectal temperature on each calf each day in the morning. The reference standard method for body temperature in the calves was rectal temperature. We assessed the data for agreement between the IRT and the reference standard using Pearson correlations by calf (accuracy), coefficients of determination (precision), and Bland-Altman plots for bias. In addition, a logistic regression model was built using the reference method as the outcome, with IRT as an explanatory variable to assess the diagnostic accuracy of IRT as an indicator of fever (rectal temperature ≥39.5°C). There was a negligible correlation between the IRT readings and rectal temperature (r = 0.22) and the coefficient of determination for IRT to predict rectal temperature was negligible (R(2) = 0.05), suggesting poor precision. The average mean difference between the IRT data and rectal temperature was 0.55°C, and the differences between IRT and rectal formed a linear line around the mean difference, suggesting the Bland-Altman analyses showed proportional error and bias. The optimal probability cut-off for IRT readings for fever was at 39.5°C, and had a receiver operating characteristic area under the curve of 0.67, a sensitivity of 61%, a specificity of 71%, and 78% (3,134/4,427) of the samples were correctly labeled as either having a fever or not using IRT readings. In summary, the IRT camera and software were not validated for serving as a proxy for rectal temperature in commercially housed calves due to poor precision, and proportional error partially explained by ambient environmental conditions. We suggest that this infrared thermography system should not replace rectal temperature readings for use in commercially housed calves.
format Online
Article
Text
id pubmed-9623779
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-96237792022-11-04 Evaluation of an infrared thermography camera for measuring body temperature in dairy calves Cantor, M.C. Goetz, H.M. Beattie, K. Renaud, D.L. JDS Commun Health, Behavior, and Well-being The objective of this diagnostic accuracy study was to validate an infrared thermography (IRT) camera and its software (FLIR One, FLIR, Global) for accuracy and precision for ocular temperature readings to serve as a proxy for rectal temperature in commercially housed calves. A total of 318 male Holstein calves were enrolled into this study from the day of arrival to a calf rearing facility until 14 d later. Researchers took an ocular temperature reading using an IRT camera, and a rectal temperature on each calf each day in the morning. The reference standard method for body temperature in the calves was rectal temperature. We assessed the data for agreement between the IRT and the reference standard using Pearson correlations by calf (accuracy), coefficients of determination (precision), and Bland-Altman plots for bias. In addition, a logistic regression model was built using the reference method as the outcome, with IRT as an explanatory variable to assess the diagnostic accuracy of IRT as an indicator of fever (rectal temperature ≥39.5°C). There was a negligible correlation between the IRT readings and rectal temperature (r = 0.22) and the coefficient of determination for IRT to predict rectal temperature was negligible (R(2) = 0.05), suggesting poor precision. The average mean difference between the IRT data and rectal temperature was 0.55°C, and the differences between IRT and rectal formed a linear line around the mean difference, suggesting the Bland-Altman analyses showed proportional error and bias. The optimal probability cut-off for IRT readings for fever was at 39.5°C, and had a receiver operating characteristic area under the curve of 0.67, a sensitivity of 61%, a specificity of 71%, and 78% (3,134/4,427) of the samples were correctly labeled as either having a fever or not using IRT readings. In summary, the IRT camera and software were not validated for serving as a proxy for rectal temperature in commercially housed calves due to poor precision, and proportional error partially explained by ambient environmental conditions. We suggest that this infrared thermography system should not replace rectal temperature readings for use in commercially housed calves. Elsevier 2022-07-09 /pmc/articles/PMC9623779/ /pubmed/36340910 http://dx.doi.org/10.3168/jdsc.2022-0227 Text en © 2022. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Health, Behavior, and Well-being
Cantor, M.C.
Goetz, H.M.
Beattie, K.
Renaud, D.L.
Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title_full Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title_fullStr Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title_full_unstemmed Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title_short Evaluation of an infrared thermography camera for measuring body temperature in dairy calves
title_sort evaluation of an infrared thermography camera for measuring body temperature in dairy calves
topic Health, Behavior, and Well-being
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623779/
https://www.ncbi.nlm.nih.gov/pubmed/36340910
http://dx.doi.org/10.3168/jdsc.2022-0227
work_keys_str_mv AT cantormc evaluationofaninfraredthermographycameraformeasuringbodytemperatureindairycalves
AT goetzhm evaluationofaninfraredthermographycameraformeasuringbodytemperatureindairycalves
AT beattiek evaluationofaninfraredthermographycameraformeasuringbodytemperatureindairycalves
AT renauddl evaluationofaninfraredthermographycameraformeasuringbodytemperatureindairycalves