Cargando…
Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring
Wastewater monitoring for severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2), the virus responsible for the global coronavirus disease 2019 (COVID-19) pandemic, has highlighted the need for methodologies capable of assessing viral prevalence during periods of low population infection....
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier/North-Holland Biomedical Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9624105/ https://www.ncbi.nlm.nih.gov/pubmed/36332716 http://dx.doi.org/10.1016/j.jviromet.2022.114645 |
_version_ | 1784822160618946560 |
---|---|
author | McMinn, Brian R. Korajkic, Asja Pemberton, Adin C. Kelleher, Julie Ahmed, Warish Villegas, Eric N. Oshima, Kevin |
author_facet | McMinn, Brian R. Korajkic, Asja Pemberton, Adin C. Kelleher, Julie Ahmed, Warish Villegas, Eric N. Oshima, Kevin |
author_sort | McMinn, Brian R. |
collection | PubMed |
description | Wastewater monitoring for severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2), the virus responsible for the global coronavirus disease 2019 (COVID-19) pandemic, has highlighted the need for methodologies capable of assessing viral prevalence during periods of low population infection. To address this need, two volumetrically different, methodologically similar concentration approaches were compared for their abilities to detect viral nucleic acid and infectious SARS-CoV-2 signal from primary influent samples. For Method 1, 2 L of SARS-CoV-2 seeded wastewater was evaluated using a dead-end hollow fiber ultrafilter (D-HFUF) for primary concentration, followed by the CP Select™ for secondary concentration. For Method 2, 100 mL of SARS-CoV-2 seeded wastewater was evaluated using the CP Select™ procedure. Following D-HFUF concentration (Method 1), significantly lower levels of infectious SARS-CoV-2 were lost (P value range: 0.0398–0.0027) compared to viral gene copy (GC) levels detected by the US Centers for Disease Control (CDC) N1 and N2 reverse-transcriptase quantitative polymerase chain reaction (RT-qPCR) assays. Subsamples at different steps in the concentration process were also taken to better characterize the losses of SARS-CoV-2 during the concentration process. During the centrifugation step (prior to CP Select™ concentration), significantly higher losses (P value range: 0.0003 to <0.0001) occurred for SARS-CoV-2 GC levels compared to infectious virus for Method 1, while between the methods, significantly higher infectious viral losses were observed for Method 2 (P = 0.0002). When analyzing overall recovery of endogenous SARS-CoV-2 in wastewater samples, application of Method 1 improved assay sensitivities (P = <0.0001) compared with Method 2; this was especially evident during periods of lower COVID-19 case rates within the sewershed. This study describes a method which can successfully concentrate infectious SARS-CoV-2 and viral RNA from wastewater. Moreover, we demonstrated that large volume wastewater concentration provides additional sensitivity needed to improve SARS-CoV-2 detection, especially during low levels of community disease prevalence. |
format | Online Article Text |
id | pubmed-9624105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier/North-Holland Biomedical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-96241052022-11-02 Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring McMinn, Brian R. Korajkic, Asja Pemberton, Adin C. Kelleher, Julie Ahmed, Warish Villegas, Eric N. Oshima, Kevin J Virol Methods Protocols Wastewater monitoring for severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2), the virus responsible for the global coronavirus disease 2019 (COVID-19) pandemic, has highlighted the need for methodologies capable of assessing viral prevalence during periods of low population infection. To address this need, two volumetrically different, methodologically similar concentration approaches were compared for their abilities to detect viral nucleic acid and infectious SARS-CoV-2 signal from primary influent samples. For Method 1, 2 L of SARS-CoV-2 seeded wastewater was evaluated using a dead-end hollow fiber ultrafilter (D-HFUF) for primary concentration, followed by the CP Select™ for secondary concentration. For Method 2, 100 mL of SARS-CoV-2 seeded wastewater was evaluated using the CP Select™ procedure. Following D-HFUF concentration (Method 1), significantly lower levels of infectious SARS-CoV-2 were lost (P value range: 0.0398–0.0027) compared to viral gene copy (GC) levels detected by the US Centers for Disease Control (CDC) N1 and N2 reverse-transcriptase quantitative polymerase chain reaction (RT-qPCR) assays. Subsamples at different steps in the concentration process were also taken to better characterize the losses of SARS-CoV-2 during the concentration process. During the centrifugation step (prior to CP Select™ concentration), significantly higher losses (P value range: 0.0003 to <0.0001) occurred for SARS-CoV-2 GC levels compared to infectious virus for Method 1, while between the methods, significantly higher infectious viral losses were observed for Method 2 (P = 0.0002). When analyzing overall recovery of endogenous SARS-CoV-2 in wastewater samples, application of Method 1 improved assay sensitivities (P = <0.0001) compared with Method 2; this was especially evident during periods of lower COVID-19 case rates within the sewershed. This study describes a method which can successfully concentrate infectious SARS-CoV-2 and viral RNA from wastewater. Moreover, we demonstrated that large volume wastewater concentration provides additional sensitivity needed to improve SARS-CoV-2 detection, especially during low levels of community disease prevalence. Elsevier/North-Holland Biomedical Press 2023-01 2022-11-01 /pmc/articles/PMC9624105/ /pubmed/36332716 http://dx.doi.org/10.1016/j.jviromet.2022.114645 Text en Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Protocols McMinn, Brian R. Korajkic, Asja Pemberton, Adin C. Kelleher, Julie Ahmed, Warish Villegas, Eric N. Oshima, Kevin Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title | Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title_full | Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title_fullStr | Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title_full_unstemmed | Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title_short | Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring |
title_sort | assessment of two volumetrically different concentration approaches to improve sensitivities for sars-cov-2 detection during wastewater monitoring |
topic | Protocols |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9624105/ https://www.ncbi.nlm.nih.gov/pubmed/36332716 http://dx.doi.org/10.1016/j.jviromet.2022.114645 |
work_keys_str_mv | AT mcminnbrianr assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT korajkicasja assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT pembertonadinc assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT kelleherjulie assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT ahmedwarish assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT villegasericn assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring AT oshimakevin assessmentoftwovolumetricallydifferentconcentrationapproachestoimprovesensitivitiesforsarscov2detectionduringwastewatermonitoring |