Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study

BACKGROUND: The effects of jet nebulization on ventilator performance in the volume control mode (VC) and pressure control mode (PC) of ventilation have not been determined. OBJECTIVES: The present study investigated the impact of jet nebulization on ventilator performance in different modes in vitr...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xinyu, Tan, Wei, Zhao, Hongwen, Wang, Wei, Dai, Bing, Hou, Haijia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9626827/
https://www.ncbi.nlm.nih.gov/pubmed/36341252
http://dx.doi.org/10.3389/fmed.2022.1004551
_version_ 1784822820504600576
author Li, Xinyu
Tan, Wei
Zhao, Hongwen
Wang, Wei
Dai, Bing
Hou, Haijia
author_facet Li, Xinyu
Tan, Wei
Zhao, Hongwen
Wang, Wei
Dai, Bing
Hou, Haijia
author_sort Li, Xinyu
collection PubMed
description BACKGROUND: The effects of jet nebulization on ventilator performance in the volume control mode (VC) and pressure control mode (PC) of ventilation have not been determined. OBJECTIVES: The present study investigated the impact of jet nebulization on ventilator performance in different modes in vitro. METHODS: Two types of jet nebulizer (ventilator-integrated jet nebulizers, external jet nebulizer) and six types of ventilator were connected with a simulated lung to simulate aerosol therapy during mechanical ventilation. The ventilation modes were set to VC and PC, and the driving flows of external jet nebulizer were set at 4 L/min and 8 L/min, respectively. Jet nebulizers were placed between patient airway and Y-piece or at 15 cm from the Y-piece in the inspiratory limb. The effects of jet nebulization were compared with the baseline of triggering performance, control performance, and tidal volume under different experimental conditions. RESULTS: Ventilator-integrated jet nebulizers had no effect on ventilator performance in different modes (all P > 0.05). However, the effects of external jet nebulizers on ventilator performance varied widely: for triggering performance, all parameters were increased in different modes and nebulization positions (all P < 0.05), including the time from the beginning of the inspiratory effort to the lowest value of airway pressure needed to trigger the ventilator (TP(min)), the time to trigger (T(trig)), and the magnitude of airway pressure drop needed to trigger (P(trig)); for control performance, peak inspiratory pressure (P(peak)) and peak inspiratory flow(P(flow)) were increased in the VC mode (P < 0.05), but not significantly changed in the PC mode (P > 0.05);the actual tidal volume (VT) and expiratory tidal volume monitored (VTe) were significantly increased (P < 0.05), however, the inspiratory tidal volume monitored (VTi) was not affected by jet nebulization in the VC mode. In the PC mode, there were no significant changes in VT, whereas VTi decreased and VTe increased (P < 0.05). The higher the driving flow of external jet nebulizers, the stronger the impact on ventilator performance (all P < 0.05). CONCLUSION: Triggering performance was decreased in both the VC and PC modes when using an external jet nebulizer, while the effects of nebulization on control performance and tidal volume varied significantly.
format Online
Article
Text
id pubmed-9626827
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-96268272022-11-03 Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study Li, Xinyu Tan, Wei Zhao, Hongwen Wang, Wei Dai, Bing Hou, Haijia Front Med (Lausanne) Medicine BACKGROUND: The effects of jet nebulization on ventilator performance in the volume control mode (VC) and pressure control mode (PC) of ventilation have not been determined. OBJECTIVES: The present study investigated the impact of jet nebulization on ventilator performance in different modes in vitro. METHODS: Two types of jet nebulizer (ventilator-integrated jet nebulizers, external jet nebulizer) and six types of ventilator were connected with a simulated lung to simulate aerosol therapy during mechanical ventilation. The ventilation modes were set to VC and PC, and the driving flows of external jet nebulizer were set at 4 L/min and 8 L/min, respectively. Jet nebulizers were placed between patient airway and Y-piece or at 15 cm from the Y-piece in the inspiratory limb. The effects of jet nebulization were compared with the baseline of triggering performance, control performance, and tidal volume under different experimental conditions. RESULTS: Ventilator-integrated jet nebulizers had no effect on ventilator performance in different modes (all P > 0.05). However, the effects of external jet nebulizers on ventilator performance varied widely: for triggering performance, all parameters were increased in different modes and nebulization positions (all P < 0.05), including the time from the beginning of the inspiratory effort to the lowest value of airway pressure needed to trigger the ventilator (TP(min)), the time to trigger (T(trig)), and the magnitude of airway pressure drop needed to trigger (P(trig)); for control performance, peak inspiratory pressure (P(peak)) and peak inspiratory flow(P(flow)) were increased in the VC mode (P < 0.05), but not significantly changed in the PC mode (P > 0.05);the actual tidal volume (VT) and expiratory tidal volume monitored (VTe) were significantly increased (P < 0.05), however, the inspiratory tidal volume monitored (VTi) was not affected by jet nebulization in the VC mode. In the PC mode, there were no significant changes in VT, whereas VTi decreased and VTe increased (P < 0.05). The higher the driving flow of external jet nebulizers, the stronger the impact on ventilator performance (all P < 0.05). CONCLUSION: Triggering performance was decreased in both the VC and PC modes when using an external jet nebulizer, while the effects of nebulization on control performance and tidal volume varied significantly. Frontiers Media S.A. 2022-10-19 /pmc/articles/PMC9626827/ /pubmed/36341252 http://dx.doi.org/10.3389/fmed.2022.1004551 Text en Copyright © 2022 Li, Tan, Zhao, Wang, Dai and Hou. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Li, Xinyu
Tan, Wei
Zhao, Hongwen
Wang, Wei
Dai, Bing
Hou, Haijia
Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title_full Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title_fullStr Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title_full_unstemmed Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title_short Effects of jet nebulization on ventilator performance with different invasive ventilation modes: A bench study
title_sort effects of jet nebulization on ventilator performance with different invasive ventilation modes: a bench study
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9626827/
https://www.ncbi.nlm.nih.gov/pubmed/36341252
http://dx.doi.org/10.3389/fmed.2022.1004551
work_keys_str_mv AT lixinyu effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy
AT tanwei effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy
AT zhaohongwen effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy
AT wangwei effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy
AT daibing effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy
AT houhaijia effectsofjetnebulizationonventilatorperformancewithdifferentinvasiveventilationmodesabenchstudy