Cargando…

Comparison of 2 Different Paclitaxel-Coated Balloons in Coronary In-Stent Restenosis: A Randomized Controlled Trial

BACKGROUND: Drug-coated balloons (DCBs) offer an effective treatment for in-stent restenosis (ISR). The Genoss DCB is a novel paclitaxel-coated balloon with a shellac plus vitamin E excipient that enhances drug delivery to the target lesion, minimizing restenosis. OBJECTIVES: This study aimed to inv...

Descripción completa

Detalles Bibliográficos
Autores principales: Jun, Eun Jung, Shin, Eun-Seok, Yuan, Song Lin, Bhak, Youngjune, Garg, Scot, Kang, Woong Chol, Kim, Je Sang, Kim, June-Hong, Bae, Jang-Whan, Rha, Seung-Woon, Chae, In-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9627897/
https://www.ncbi.nlm.nih.gov/pubmed/36339121
http://dx.doi.org/10.1016/j.jacasi.2021.11.015
Descripción
Sumario:BACKGROUND: Drug-coated balloons (DCBs) offer an effective treatment for in-stent restenosis (ISR). The Genoss DCB is a novel paclitaxel-coated balloon with a shellac plus vitamin E excipient that enhances drug delivery to the target lesion, minimizing restenosis. OBJECTIVES: This study aimed to investigate the angiographic efficacy, clinical safety, and effectiveness of the novel shellac plus vitamin E–based DCB in a randomized controlled trial designed to enable regulatory approval of this new device in South Korea. METHODS: This noninferiority trial randomized patients experiencing their first ISR to the novel shellac plus vitamin E–based DCB or the reference SeQuent Please iopromide-based DCB in a 1:1 ratio. All patients underwent planned angiographic and clinical follow-up at 6 months. The study was powered for the primary endpoint of 6 months in-segment late lumen loss (LLL). RESULTS: A total of 82 patients from 7 centers were randomized to either the novel shellac plus vitamin E–based DCB group (n = 41) or the reference iopromide-based DCB group (n = 41). The 6-month in-segment LLL was 0.15 ± 0.43 mm with the novel DCB compared with 0.24 ± 0.39 mm with the reference device. The 1-sided 97.5% upper confidence limit of the difference was 0.13 mm, lower than the noninferiority limit of 0.29 mm, achieving noninferiority (P for noninferiority = 0.001). Major cardiovascular events were comparable between 2 groups at 6 months (7.7% for the novel DCB vs 10.3% for the reference DCB; P = 0.692). CONCLUSIONS: In this multicenter, head-to-head comparison randomized trial, the novel shellac plus vitamin E–based DCB showed a comparable result to the reference iopromide-based device for the primary endpoint of 6-month in-segment LLL for the treatment of coronary ISR. (Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please in Korean Patient With Coronary In-stent Restenosis; NCT04405063)