Cargando…

Specimen mammography for intraoperative margin assessment in breast conserving surgery: a meta-analysis

In breast conserving surgery (BCS), specimen mammography is one of the most widely used intraoperative methods of assessing margin status. We performed a meta-analysis to evaluate the diagnostic accuracy of specimen mammography. Literature databases including PubMed, Cochrane Library, Web of Science...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Chen, Wang, Kai-yue, Chen, Hai-lang, Xu, Yu-hua, Pan, Tao, Chen, Yi-ding
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9630505/
https://www.ncbi.nlm.nih.gov/pubmed/36323863
http://dx.doi.org/10.1038/s41598-022-23234-5
Descripción
Sumario:In breast conserving surgery (BCS), specimen mammography is one of the most widely used intraoperative methods of assessing margin status. We performed a meta-analysis to evaluate the diagnostic accuracy of specimen mammography. Literature databases including PubMed, Cochrane Library, Web of Science, and EMBASE were searched prior to Jun 2022. A total of 1967 patients were included from 20 studies. A pooled analysis, heterogeneity testing, threshold effect testing, publication bias analysis, and subgroup analyses were performed from extracted data. The pooled weighted values were a sensitivity of 0.55 (95% confidence interval [CI], 0.47–0.63), a specificity of 0.85 (95% CI, 0.78–0.90), a diagnostic odds ratio of 7 (95% CI, 4–12), and a pooled positive likelihood ratio of 3.7 (95% CI 2.6–5.5). The area under the receiver operator characteristic curve was 0.75 (95% CI 0.71–0.78). In the subgroup analysis, the pooled specificity in the positive margin defined as tumor at margin subgroup was lower than the other positive margin definition subgroup (0.82 [95% CI: 0.71, 0.92] vs. 0.87 [95% CI: 0.80, 0.94], p = 0.01). Our findings indicated that specimen mammography was an accurate intraoperative imaging technique for margin assessment in BCS.