Cargando…

Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs

OBJECTIVE: To evaluate the accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in the canine thoracolumbar vertebral column. STUDY DESIGN: In vitro imaging and anatomic study. ANIMALS: Canine cadaveric thoracolumbar vertebral columns (n = 5). METHODS: Smo...

Descripción completa

Detalles Bibliográficos
Autores principales: Goffart, Laura M., Precht, Christina, Fosgate, Geoffrey T., Maiolini, Arianna, Hettlich, Bianca F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9630941/
https://www.ncbi.nlm.nih.gov/pubmed/36337187
http://dx.doi.org/10.3389/fvets.2022.982560
_version_ 1784823717814075392
author Goffart, Laura M.
Precht, Christina
Fosgate, Geoffrey T.
Maiolini, Arianna
Hettlich, Bianca F.
author_facet Goffart, Laura M.
Precht, Christina
Fosgate, Geoffrey T.
Maiolini, Arianna
Hettlich, Bianca F.
author_sort Goffart, Laura M.
collection PubMed
description OBJECTIVE: To evaluate the accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in the canine thoracolumbar vertebral column. STUDY DESIGN: In vitro imaging and anatomic study. ANIMALS: Canine cadaveric thoracolumbar vertebral columns (n = 5). METHODS: Smooth Steinmann pins were inserted bicortically into the thoracolumbar vertebral columns between T10 and L7 using recommended insertion angles. Penetration of the spinal canal was not strictly avoided. After pin placement, end-on fluoroscopy images were obtained of each pin. Pin position was subsequently assessed by four evaluators and determined to either being out of the vertebral canal or in, with the latter being additionally divided into partially or completely penetrating the canal. To assess potential differences in modalities, fluoroscopy images were gray-scale inverted and evaluated again later by the same four individuals. Correct identification of pin position in relationship to the vertebral canal was assessed for both fluoroscopy images. Anatomic preparation of the spines was used for verification of pin position in relation to the spinal canal. Some data from this study were compared with historical data on accuracy using orthogonal radiography and computed tomography (CT). RESULTS: Overall sensitivity and specificity of F to detect vertebral canal penetration was 98.8 % (95% confidence interval (CI), 96.0–99.6) and 98.0% (95% CI, 77.0–99.9), respectively. For Fi, sensitivity and specificity were 97.0% (95% CI, 91.5–99.0) and 98.5% (95% CI, 81.5–99.9) respectively. F exceeded Fi for the sensitivity of detecting pin penetration into the vertebral canal (p = 0.039) but specificities were not different (p = 0.585). When comparing to historical data, the overall accuracy of end-on fluoroscopy (F) and inverted fluoroscopy (Fi) was statistical better than conventional radiographic assessment (p < 0.001). CONCLUSION: End-on fluoroscopy is a highly accurate method for the assessment of pin position in relationship to the thoracolumbar spinal canal in cadaveric dogs. CLINICAL SIGNIFICANCE: End-on fluoroscopy, with or without inversion, is accurate in identifying vertebral canal violation by bicortically placed Steinmann pins. When CT is not available, end-on fluoroscopy might be a valuable imaging modality to determine pin position in the canine vertebral column.
format Online
Article
Text
id pubmed-9630941
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-96309412022-11-04 Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs Goffart, Laura M. Precht, Christina Fosgate, Geoffrey T. Maiolini, Arianna Hettlich, Bianca F. Front Vet Sci Veterinary Science OBJECTIVE: To evaluate the accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in the canine thoracolumbar vertebral column. STUDY DESIGN: In vitro imaging and anatomic study. ANIMALS: Canine cadaveric thoracolumbar vertebral columns (n = 5). METHODS: Smooth Steinmann pins were inserted bicortically into the thoracolumbar vertebral columns between T10 and L7 using recommended insertion angles. Penetration of the spinal canal was not strictly avoided. After pin placement, end-on fluoroscopy images were obtained of each pin. Pin position was subsequently assessed by four evaluators and determined to either being out of the vertebral canal or in, with the latter being additionally divided into partially or completely penetrating the canal. To assess potential differences in modalities, fluoroscopy images were gray-scale inverted and evaluated again later by the same four individuals. Correct identification of pin position in relationship to the vertebral canal was assessed for both fluoroscopy images. Anatomic preparation of the spines was used for verification of pin position in relation to the spinal canal. Some data from this study were compared with historical data on accuracy using orthogonal radiography and computed tomography (CT). RESULTS: Overall sensitivity and specificity of F to detect vertebral canal penetration was 98.8 % (95% confidence interval (CI), 96.0–99.6) and 98.0% (95% CI, 77.0–99.9), respectively. For Fi, sensitivity and specificity were 97.0% (95% CI, 91.5–99.0) and 98.5% (95% CI, 81.5–99.9) respectively. F exceeded Fi for the sensitivity of detecting pin penetration into the vertebral canal (p = 0.039) but specificities were not different (p = 0.585). When comparing to historical data, the overall accuracy of end-on fluoroscopy (F) and inverted fluoroscopy (Fi) was statistical better than conventional radiographic assessment (p < 0.001). CONCLUSION: End-on fluoroscopy is a highly accurate method for the assessment of pin position in relationship to the thoracolumbar spinal canal in cadaveric dogs. CLINICAL SIGNIFICANCE: End-on fluoroscopy, with or without inversion, is accurate in identifying vertebral canal violation by bicortically placed Steinmann pins. When CT is not available, end-on fluoroscopy might be a valuable imaging modality to determine pin position in the canine vertebral column. Frontiers Media S.A. 2022-10-20 /pmc/articles/PMC9630941/ /pubmed/36337187 http://dx.doi.org/10.3389/fvets.2022.982560 Text en Copyright © 2022 Goffart, Precht, Fosgate, Maiolini and Hettlich. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Goffart, Laura M.
Precht, Christina
Fosgate, Geoffrey T.
Maiolini, Arianna
Hettlich, Bianca F.
Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title_full Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title_fullStr Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title_full_unstemmed Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title_short Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
title_sort accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9630941/
https://www.ncbi.nlm.nih.gov/pubmed/36337187
http://dx.doi.org/10.3389/fvets.2022.982560
work_keys_str_mv AT goffartlauram accuracyofendonfluoroscopyinpredictingimplantpositioninrelationtothevertebralcanalindogs
AT prechtchristina accuracyofendonfluoroscopyinpredictingimplantpositioninrelationtothevertebralcanalindogs
AT fosgategeoffreyt accuracyofendonfluoroscopyinpredictingimplantpositioninrelationtothevertebralcanalindogs
AT maioliniarianna accuracyofendonfluoroscopyinpredictingimplantpositioninrelationtothevertebralcanalindogs
AT hettlichbiancaf accuracyofendonfluoroscopyinpredictingimplantpositioninrelationtothevertebralcanalindogs