Cargando…

Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode

[Image: see text] Transport phenomena in microfluidic chips are induced by electric fields and electrolyte concentrations. Liquid flows are often affected by ionic currents driven by electric fields in narrow channels, which are applied in microelectromechanical systems, microreactors, lab-on-a-chip...

Descripción completa

Detalles Bibliográficos
Autores principales: Kishimoto, Tatsunori, Doi, Kentaro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9631736/
https://www.ncbi.nlm.nih.gov/pubmed/36340092
http://dx.doi.org/10.1021/acsomega.2c05973
_version_ 1784823880427241472
author Kishimoto, Tatsunori
Doi, Kentaro
author_facet Kishimoto, Tatsunori
Doi, Kentaro
author_sort Kishimoto, Tatsunori
collection PubMed
description [Image: see text] Transport phenomena in microfluidic chips are induced by electric fields and electrolyte concentrations. Liquid flows are often affected by ionic currents driven by electric fields in narrow channels, which are applied in microelectromechanical systems, microreactors, lab-on-a-chip, and so forth. Even though numerical studies to evaluate those local fields have been reported, measurement methods seem to be under construction. To deeply understand the dynamics of ions at the microscale, measurement techniques are necessary to be developed. In this study, we propose a novel method to directly measure electrical potential differences in liquids, local electric fields, and electrical conductivities, using a glass microelectrode. Scanning an electrolyte solution, for example, KCl solutions, with a 1 μm tip under constant ionic current conditions, a potential difference in liquids is locally measured with a micrometer-scale resolution. The conductivity of KCl solutions ranging from 0.56 to 100 mM is evaluated from electric fields locally measured, and errors are within 5% compared with the reference values. It is found that the present method enables us to directly measure local electric fields under constant current and that the electrical conductivity is quantitatively evaluated. Furthermore, it is suggested that the present method is available for various electrical analyses without calibration procedures before measurements.
format Online
Article
Text
id pubmed-9631736
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-96317362022-11-04 Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode Kishimoto, Tatsunori Doi, Kentaro ACS Omega [Image: see text] Transport phenomena in microfluidic chips are induced by electric fields and electrolyte concentrations. Liquid flows are often affected by ionic currents driven by electric fields in narrow channels, which are applied in microelectromechanical systems, microreactors, lab-on-a-chip, and so forth. Even though numerical studies to evaluate those local fields have been reported, measurement methods seem to be under construction. To deeply understand the dynamics of ions at the microscale, measurement techniques are necessary to be developed. In this study, we propose a novel method to directly measure electrical potential differences in liquids, local electric fields, and electrical conductivities, using a glass microelectrode. Scanning an electrolyte solution, for example, KCl solutions, with a 1 μm tip under constant ionic current conditions, a potential difference in liquids is locally measured with a micrometer-scale resolution. The conductivity of KCl solutions ranging from 0.56 to 100 mM is evaluated from electric fields locally measured, and errors are within 5% compared with the reference values. It is found that the present method enables us to directly measure local electric fields under constant current and that the electrical conductivity is quantitatively evaluated. Furthermore, it is suggested that the present method is available for various electrical analyses without calibration procedures before measurements. American Chemical Society 2022-10-21 /pmc/articles/PMC9631736/ /pubmed/36340092 http://dx.doi.org/10.1021/acsomega.2c05973 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Kishimoto, Tatsunori
Doi, Kentaro
Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title_full Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title_fullStr Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title_full_unstemmed Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title_short Local Electric Field and Electrical Conductivity Analysis Using a Glass Microelectrode
title_sort local electric field and electrical conductivity analysis using a glass microelectrode
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9631736/
https://www.ncbi.nlm.nih.gov/pubmed/36340092
http://dx.doi.org/10.1021/acsomega.2c05973
work_keys_str_mv AT kishimototatsunori localelectricfieldandelectricalconductivityanalysisusingaglassmicroelectrode
AT doikentaro localelectricfieldandelectricalconductivityanalysisusingaglassmicroelectrode