Cargando…

Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research

BACKGROUND: Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. OBJECTIVES: To deter...

Descripción completa

Detalles Bibliográficos
Autores principales: Pereiro-Buceta, Héctor, Calvo-Lobo, César, Becerro-de-Bengoa-Vallejo, Ricardo, Losa-Iglesias, Marta Elena, Romero-Morales, Carlos, López-López, Daniel, Martínez-Jiménez, Eva-María
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação Paulista de Medicina - APM 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632525/
https://www.ncbi.nlm.nih.gov/pubmed/34190874
http://dx.doi.org/10.1590/1516-3180.2020.0791.R1.110321
_version_ 1784824047450718208
author Pereiro-Buceta, Héctor
Calvo-Lobo, César
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Romero-Morales, Carlos
López-López, Daniel
Martínez-Jiménez, Eva-María
author_facet Pereiro-Buceta, Héctor
Calvo-Lobo, César
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Romero-Morales, Carlos
López-López, Daniel
Martínez-Jiménez, Eva-María
author_sort Pereiro-Buceta, Héctor
collection PubMed
description BACKGROUND: Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. OBJECTIVES: To determine the intra and intersession repeatability and reliability of dynamic parameters of the Podoprint pressure platform under simulated LLD conditions. DESIGN AND SETTING: Observational cross-sectional study at a public university. METHODS: Thirty-seven healthy volunteers participated in this study. LLD was simulated using ethyl vinyl acetate plantar lifts with heights of 5 mm, 10 mm, 15 mm and 20 mm located under the right shoe of each volunteer. The procedure was performed to capture the dynamic parameters of each participant under five different simulated LLD conditions. Stance time, mean pressure and peak pressure measurements were registered in three trials for each foot and each LLD level. Data were collected during two separate testing sessions, in order to establish intrasession and intersession reliability. RESULTS: The intraclass correlation coefficients (ICCs) for intrasession reliability ranged from 0.775 to 0.983 in the first session and from 0.860 to 0.985 in the second session. The ICCs for intersession reliability ranged from 0.909 to 0.990. Bland-Altman plots showed absence of systematic measurement errors. CONCLUSIONS: The results from this study indicate that the Podoprint platform is a reliable system for assessing dynamic parameters under simulated LLD conditions. Future studies should evaluate plantar pressures under LLD conditions, in association with exercise, biomechanics and musculoskeletal disorders.
format Online
Article
Text
id pubmed-9632525
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Associação Paulista de Medicina - APM
record_format MEDLINE/PubMed
spelling pubmed-96325252022-11-04 Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research Pereiro-Buceta, Héctor Calvo-Lobo, César Becerro-de-Bengoa-Vallejo, Ricardo Losa-Iglesias, Marta Elena Romero-Morales, Carlos López-López, Daniel Martínez-Jiménez, Eva-María Sao Paulo Med J Original Article BACKGROUND: Leg length discrepancy (LLD) may play a key role in exercise biomechanics. Although the Podoprint platform has been used in dynamic pressure studies, there are no data regarding the reliability and repeatability of dynamic measurements under simulated LLD conditions. OBJECTIVES: To determine the intra and intersession repeatability and reliability of dynamic parameters of the Podoprint pressure platform under simulated LLD conditions. DESIGN AND SETTING: Observational cross-sectional study at a public university. METHODS: Thirty-seven healthy volunteers participated in this study. LLD was simulated using ethyl vinyl acetate plantar lifts with heights of 5 mm, 10 mm, 15 mm and 20 mm located under the right shoe of each volunteer. The procedure was performed to capture the dynamic parameters of each participant under five different simulated LLD conditions. Stance time, mean pressure and peak pressure measurements were registered in three trials for each foot and each LLD level. Data were collected during two separate testing sessions, in order to establish intrasession and intersession reliability. RESULTS: The intraclass correlation coefficients (ICCs) for intrasession reliability ranged from 0.775 to 0.983 in the first session and from 0.860 to 0.985 in the second session. The ICCs for intersession reliability ranged from 0.909 to 0.990. Bland-Altman plots showed absence of systematic measurement errors. CONCLUSIONS: The results from this study indicate that the Podoprint platform is a reliable system for assessing dynamic parameters under simulated LLD conditions. Future studies should evaluate plantar pressures under LLD conditions, in association with exercise, biomechanics and musculoskeletal disorders. Associação Paulista de Medicina - APM 2021-06-25 /pmc/articles/PMC9632525/ /pubmed/34190874 http://dx.doi.org/10.1590/1516-3180.2020.0791.R1.110321 Text en © 2022 by Associação Paulista de Medicina https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons license.
spellingShingle Original Article
Pereiro-Buceta, Héctor
Calvo-Lobo, César
Becerro-de-Bengoa-Vallejo, Ricardo
Losa-Iglesias, Marta Elena
Romero-Morales, Carlos
López-López, Daniel
Martínez-Jiménez, Eva-María
Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title_full Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title_fullStr Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title_full_unstemmed Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title_short Intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. A cross-sectional research
title_sort intra and intersession repeatability and reliability of dynamic parameters in pressure platform assessments on subjects with simulated leg length discrepancy. a cross-sectional research
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632525/
https://www.ncbi.nlm.nih.gov/pubmed/34190874
http://dx.doi.org/10.1590/1516-3180.2020.0791.R1.110321
work_keys_str_mv AT pereirobucetahector intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT calvolobocesar intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT becerrodebengoavallejoricardo intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT losaiglesiasmartaelena intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT romeromoralescarlos intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT lopezlopezdaniel intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch
AT martinezjimenezevamaria intraandintersessionrepeatabilityandreliabilityofdynamicparametersinpressureplatformassessmentsonsubjectswithsimulatedleglengthdiscrepancyacrosssectionalresearch