Cargando…

Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study

Retrospective multicenter. OBJECTIVE. The aim was to investigate the factors involved in, and their relative contributions to, the overall accuracy of robot-assisted pedicle screw placement. SUMMARY OF BACKGROUND DATA. Robot-assisted surgery has reportedly resulted in greater accuracy for placement...

Descripción completa

Detalles Bibliográficos
Autores principales: Toossi, Nader, Vardiman, Arnold B., Benech, Carlo A., Kanaly, Charles W., Maltenfort, Mitchell G., Backes, Danielle M., Bucklen, Brandon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632944/
https://www.ncbi.nlm.nih.gov/pubmed/36256605
http://dx.doi.org/10.1097/BRS.0000000000004473
_version_ 1784824151551246336
author Toossi, Nader
Vardiman, Arnold B.
Benech, Carlo A.
Kanaly, Charles W.
Maltenfort, Mitchell G.
Backes, Danielle M.
Bucklen, Brandon
author_facet Toossi, Nader
Vardiman, Arnold B.
Benech, Carlo A.
Kanaly, Charles W.
Maltenfort, Mitchell G.
Backes, Danielle M.
Bucklen, Brandon
author_sort Toossi, Nader
collection PubMed
description Retrospective multicenter. OBJECTIVE. The aim was to investigate the factors involved in, and their relative contributions to, the overall accuracy of robot-assisted pedicle screw placement. SUMMARY OF BACKGROUND DATA. Robot-assisted surgery has reportedly resulted in greater accuracy for placement of pedicle screws than conventional methods. There are many potential factors affecting the accuracy of pedicle screws placed with a robot. No study has investigated these factors in a robust way. MATERIALS AND METHODS. Radiographic and clinical data of three centers were pooled. Preoperative and postoperative computerized tomographies were obtained by all three centers to assess the accuracy of the placed screws. The primary outcome measured was accuracy of pedicle screws placed with the robot. The authors performed a multivariate regression analysis to determine the significant patient-related and screw-related variables and their relative contribution to the overall accuracy. In addition, an ordinal regression analysis was conducted to investigate the effects of different variables on accuracy of robot-placed screws graded by Gertzbein-Robbins grading system (GRS). RESULTS. The total contribution of all studied variables to overall accuracy variation as measured by offsets between the placed and planned screws was only 18%. Obesity, long constructs, female gender, surgeon, and vertebral levels were among the factors that had small contributions to the different screw offsets. For GRS grades, significant variables were gender (Log odds: 0.62, 95% CI: 0.38–0.85), age (Log odds: 0.02, 95% CI: 0.01–0.03), length of constructs (Log odds: 0.07, 95% CI: 0.02–0.11), screw diameter (Log odds: 0.55, 95% CI: 0.39–0.71), and length of the screws (Log odds: 0.03, 95% CI: 0.01–0.05). However, these variables too, regardless of their significant association with the accuracy of placed screws, had little contribution to overall variability of accuracy itself (only about 7%). CONCLUSION. The accuracy of screws placed with robotic assistance, as graded by GRS or measured offsets between planned and placed screw trajectories, is minimally affected by different patient-related or screw-related variables due to the robustness of the robotic navigation system used in this study. LEVEL OF EVIDENCE. Level III.
format Online
Article
Text
id pubmed-9632944
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-96329442022-11-04 Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study Toossi, Nader Vardiman, Arnold B. Benech, Carlo A. Kanaly, Charles W. Maltenfort, Mitchell G. Backes, Danielle M. Bucklen, Brandon Spine (Phila Pa 1976) Surgery Retrospective multicenter. OBJECTIVE. The aim was to investigate the factors involved in, and their relative contributions to, the overall accuracy of robot-assisted pedicle screw placement. SUMMARY OF BACKGROUND DATA. Robot-assisted surgery has reportedly resulted in greater accuracy for placement of pedicle screws than conventional methods. There are many potential factors affecting the accuracy of pedicle screws placed with a robot. No study has investigated these factors in a robust way. MATERIALS AND METHODS. Radiographic and clinical data of three centers were pooled. Preoperative and postoperative computerized tomographies were obtained by all three centers to assess the accuracy of the placed screws. The primary outcome measured was accuracy of pedicle screws placed with the robot. The authors performed a multivariate regression analysis to determine the significant patient-related and screw-related variables and their relative contribution to the overall accuracy. In addition, an ordinal regression analysis was conducted to investigate the effects of different variables on accuracy of robot-placed screws graded by Gertzbein-Robbins grading system (GRS). RESULTS. The total contribution of all studied variables to overall accuracy variation as measured by offsets between the placed and planned screws was only 18%. Obesity, long constructs, female gender, surgeon, and vertebral levels were among the factors that had small contributions to the different screw offsets. For GRS grades, significant variables were gender (Log odds: 0.62, 95% CI: 0.38–0.85), age (Log odds: 0.02, 95% CI: 0.01–0.03), length of constructs (Log odds: 0.07, 95% CI: 0.02–0.11), screw diameter (Log odds: 0.55, 95% CI: 0.39–0.71), and length of the screws (Log odds: 0.03, 95% CI: 0.01–0.05). However, these variables too, regardless of their significant association with the accuracy of placed screws, had little contribution to overall variability of accuracy itself (only about 7%). CONCLUSION. The accuracy of screws placed with robotic assistance, as graded by GRS or measured offsets between planned and placed screw trajectories, is minimally affected by different patient-related or screw-related variables due to the robustness of the robotic navigation system used in this study. LEVEL OF EVIDENCE. Level III. Lippincott Williams & Wilkins 2022-12-01 2022-10-17 /pmc/articles/PMC9632944/ /pubmed/36256605 http://dx.doi.org/10.1097/BRS.0000000000004473 Text en © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Surgery
Toossi, Nader
Vardiman, Arnold B.
Benech, Carlo A.
Kanaly, Charles W.
Maltenfort, Mitchell G.
Backes, Danielle M.
Bucklen, Brandon
Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title_full Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title_fullStr Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title_full_unstemmed Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title_short Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery: A Multicenter Study
title_sort factors affecting the accuracy of pedicle screw placement in robot-assisted surgery: a multicenter study
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632944/
https://www.ncbi.nlm.nih.gov/pubmed/36256605
http://dx.doi.org/10.1097/BRS.0000000000004473
work_keys_str_mv AT toossinader factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT vardimanarnoldb factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT benechcarloa factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT kanalycharlesw factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT maltenfortmitchellg factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT backesdaniellem factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy
AT bucklenbrandon factorsaffectingtheaccuracyofpediclescrewplacementinrobotassistedsurgeryamulticenterstudy