Cargando…

Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion

STUDY DESIGN: This study compares four cervical endplate removal procedures, validated by finite element models. PURPOSE: To characterize the effect of biomechanical strength and increased contact area on the maximum von Mises stress, migration, and subsidence between the cancellous bone, endplate,...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Maohua, Paul, Rudy, Shapiro, Stephen Z., Doulgeris, James, O’Connor, Timothy E., Tsai, Chi-Tay, Vrionis, Frank D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9633244/
https://www.ncbi.nlm.nih.gov/pubmed/35263829
http://dx.doi.org/10.31616/asj.2021.0424
_version_ 1784824219469611008
author Lin, Maohua
Paul, Rudy
Shapiro, Stephen Z.
Doulgeris, James
O’Connor, Timothy E.
Tsai, Chi-Tay
Vrionis, Frank D.
author_facet Lin, Maohua
Paul, Rudy
Shapiro, Stephen Z.
Doulgeris, James
O’Connor, Timothy E.
Tsai, Chi-Tay
Vrionis, Frank D.
author_sort Lin, Maohua
collection PubMed
description STUDY DESIGN: This study compares four cervical endplate removal procedures, validated by finite element models. PURPOSE: To characterize the effect of biomechanical strength and increased contact area on the maximum von Mises stress, migration, and subsidence between the cancellous bone, endplate, and implanted cage. OVERVIEW OF LITERATURE: Anterior cervical discectomy and fusion (ACDF) has been widely used for treating patients with degenerative spondylosis. However, no direct correlations have been drawn that incorporate the impact of the contact area between the cage and the vertebra/endplate. METHODS: Model 1 (M1) was an intact C2C6 model with a 0.5 mm endplate. In model 2 (M2), a cage was implanted after removal of the C4–C5 and C5–C6 discs with preservation of the osseous endplate. In model 3 (M3), 1 mm of the osseous endplate was removed at the upper endplate. Model 4 (M4) resembles M3, except that 3 mm of the osseous endplate was removed. RESULTS: The range of motion (ROM) at C2C6 in the M2–M4 models was reduced by at least 9° compared to the M1 model. The von Mises stress results in the C2C3 and C3C4 interbody discs were significantly smaller in the M1 model and slightly increased in the M2–M3 and M3–M4 models. Migration and subsidence decreased from the M2–M3 model, whereas further endplate removal increased the migration and subsidence as shown in the transition from M3 to M4. CONCLUSIONS: The M3 model had the least subsidence and migration. The ROM was higher in the M3 model than the M2 and M4 models. Endplate preparation created small stress differences in the healthy intervertebral discs above the ACDF site. A 1 mm embedding depth created the best balance of mechanical strength and contact area, resulting in the most favorable stability of the construct.
format Online
Article
Text
id pubmed-9633244
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-96332442022-11-14 Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion Lin, Maohua Paul, Rudy Shapiro, Stephen Z. Doulgeris, James O’Connor, Timothy E. Tsai, Chi-Tay Vrionis, Frank D. Asian Spine J Basic Study STUDY DESIGN: This study compares four cervical endplate removal procedures, validated by finite element models. PURPOSE: To characterize the effect of biomechanical strength and increased contact area on the maximum von Mises stress, migration, and subsidence between the cancellous bone, endplate, and implanted cage. OVERVIEW OF LITERATURE: Anterior cervical discectomy and fusion (ACDF) has been widely used for treating patients with degenerative spondylosis. However, no direct correlations have been drawn that incorporate the impact of the contact area between the cage and the vertebra/endplate. METHODS: Model 1 (M1) was an intact C2C6 model with a 0.5 mm endplate. In model 2 (M2), a cage was implanted after removal of the C4–C5 and C5–C6 discs with preservation of the osseous endplate. In model 3 (M3), 1 mm of the osseous endplate was removed at the upper endplate. Model 4 (M4) resembles M3, except that 3 mm of the osseous endplate was removed. RESULTS: The range of motion (ROM) at C2C6 in the M2–M4 models was reduced by at least 9° compared to the M1 model. The von Mises stress results in the C2C3 and C3C4 interbody discs were significantly smaller in the M1 model and slightly increased in the M2–M3 and M3–M4 models. Migration and subsidence decreased from the M2–M3 model, whereas further endplate removal increased the migration and subsidence as shown in the transition from M3 to M4. CONCLUSIONS: The M3 model had the least subsidence and migration. The ROM was higher in the M3 model than the M2 and M4 models. Endplate preparation created small stress differences in the healthy intervertebral discs above the ACDF site. A 1 mm embedding depth created the best balance of mechanical strength and contact area, resulting in the most favorable stability of the construct. Korean Society of Spine Surgery 2022-10 2022-03-11 /pmc/articles/PMC9633244/ /pubmed/35263829 http://dx.doi.org/10.31616/asj.2021.0424 Text en Copyright © 2022 by Korean Society of Spine Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Basic Study
Lin, Maohua
Paul, Rudy
Shapiro, Stephen Z.
Doulgeris, James
O’Connor, Timothy E.
Tsai, Chi-Tay
Vrionis, Frank D.
Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title_full Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title_fullStr Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title_full_unstemmed Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title_short Biomechanical Study of Cervical Endplate Removal on Subsidence and Migration in Multilevel Anterior Cervical Discectomy and Fusion
title_sort biomechanical study of cervical endplate removal on subsidence and migration in multilevel anterior cervical discectomy and fusion
topic Basic Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9633244/
https://www.ncbi.nlm.nih.gov/pubmed/35263829
http://dx.doi.org/10.31616/asj.2021.0424
work_keys_str_mv AT linmaohua biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT paulrudy biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT shapirostephenz biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT doulgerisjames biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT oconnortimothye biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT tsaichitay biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion
AT vrionisfrankd biomechanicalstudyofcervicalendplateremovalonsubsidenceandmigrationinmultilevelanteriorcervicaldiscectomyandfusion