Cargando…

Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants

[Image: see text] The lack of chromatographic separation in ambient and direct mass spectrometry (MS) ionization techniques jeopardizes the overall selectivity of the developed methods. Incorporating a biosensing element at the ionization source could compensate for that inherent lack of selectivity...

Descripción completa

Detalles Bibliográficos
Autores principales: Geballa-Koukoula, Ariadni, Gerssen, Arjen, Blokland, Marco H., Nielen, Michel W. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9634800/
https://www.ncbi.nlm.nih.gov/pubmed/36223493
http://dx.doi.org/10.1021/jasms.2c00149
_version_ 1784824576211943424
author Geballa-Koukoula, Ariadni
Gerssen, Arjen
Blokland, Marco H.
Nielen, Michel W. F.
author_facet Geballa-Koukoula, Ariadni
Gerssen, Arjen
Blokland, Marco H.
Nielen, Michel W. F.
author_sort Geballa-Koukoula, Ariadni
collection PubMed
description [Image: see text] The lack of chromatographic separation in ambient and direct mass spectrometry (MS) ionization techniques jeopardizes the overall selectivity of the developed methods. Incorporating a biosensing element at the ionization source could compensate for that inherent lack of selectivity. Thus, a simplified immunoaffinity-direct MS technique was developed, immunoaffinity blade spray (iBS), featuring a conductive polystyrene blade material. In iBS, the generic coating used in conventional coated blade spray is replaced with a layer of highly specific monoclonal antibodies (mAbs), while the stainless steel is replaced with conductive polystyrene to allow for simple ELISA platelike hydrophobic immobilization of mAbs. Because of its high relevance for climate change-induced food safety issues, the mycotoxin deoxynivalenol (DON) was chosen as a model substance. Following a rapid extraction from wheat flour, DON is immuno-captured, and the blade is positioned in front of the MS for direct iBS-MS/MS analysis. The method’s applicability was demonstrated by analyzing spiked and incurred wheat flour samples, omitting the need for time-consuming chromatographic separation. Apart from DON, cross-reacting DON conjugates could be successfully analyzed as well. The direct iBS-MS/MS method is generic and adaptable to detecting any analyte in sample extracts, provided that specific mAbs are available.
format Online
Article
Text
id pubmed-9634800
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-96348002022-11-05 Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants Geballa-Koukoula, Ariadni Gerssen, Arjen Blokland, Marco H. Nielen, Michel W. F. J Am Soc Mass Spectrom [Image: see text] The lack of chromatographic separation in ambient and direct mass spectrometry (MS) ionization techniques jeopardizes the overall selectivity of the developed methods. Incorporating a biosensing element at the ionization source could compensate for that inherent lack of selectivity. Thus, a simplified immunoaffinity-direct MS technique was developed, immunoaffinity blade spray (iBS), featuring a conductive polystyrene blade material. In iBS, the generic coating used in conventional coated blade spray is replaced with a layer of highly specific monoclonal antibodies (mAbs), while the stainless steel is replaced with conductive polystyrene to allow for simple ELISA platelike hydrophobic immobilization of mAbs. Because of its high relevance for climate change-induced food safety issues, the mycotoxin deoxynivalenol (DON) was chosen as a model substance. Following a rapid extraction from wheat flour, DON is immuno-captured, and the blade is positioned in front of the MS for direct iBS-MS/MS analysis. The method’s applicability was demonstrated by analyzing spiked and incurred wheat flour samples, omitting the need for time-consuming chromatographic separation. Apart from DON, cross-reacting DON conjugates could be successfully analyzed as well. The direct iBS-MS/MS method is generic and adaptable to detecting any analyte in sample extracts, provided that specific mAbs are available. American Chemical Society 2022-10-12 2022-11-02 /pmc/articles/PMC9634800/ /pubmed/36223493 http://dx.doi.org/10.1021/jasms.2c00149 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Geballa-Koukoula, Ariadni
Gerssen, Arjen
Blokland, Marco H.
Nielen, Michel W. F.
Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title_full Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title_fullStr Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title_full_unstemmed Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title_short Immunoaffinity Plastic Blade Spray Mass Spectrometry for Rapid Confirmatory Analysis of Food Contaminants
title_sort immunoaffinity plastic blade spray mass spectrometry for rapid confirmatory analysis of food contaminants
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9634800/
https://www.ncbi.nlm.nih.gov/pubmed/36223493
http://dx.doi.org/10.1021/jasms.2c00149
work_keys_str_mv AT geballakoukoulaariadni immunoaffinityplasticbladespraymassspectrometryforrapidconfirmatoryanalysisoffoodcontaminants
AT gerssenarjen immunoaffinityplasticbladespraymassspectrometryforrapidconfirmatoryanalysisoffoodcontaminants
AT bloklandmarcoh immunoaffinityplasticbladespraymassspectrometryforrapidconfirmatoryanalysisoffoodcontaminants
AT nielenmichelwf immunoaffinityplasticbladespraymassspectrometryforrapidconfirmatoryanalysisoffoodcontaminants