Cargando…

The correlation between two occlusal analyzers for the measurement of bite force

BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.)...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yi-Fang, Wang, Chin-Man, Shieh, Wann-Yun, Liao, Yu-Fang, Hong, Hsiang-Hsi, Chang, Chung-Ta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9636614/
https://www.ncbi.nlm.nih.gov/pubmed/36335336
http://dx.doi.org/10.1186/s12903-022-02484-9
_version_ 1784824984648024064
author Huang, Yi-Fang
Wang, Chin-Man
Shieh, Wann-Yun
Liao, Yu-Fang
Hong, Hsiang-Hsi
Chang, Chung-Ta
author_facet Huang, Yi-Fang
Wang, Chin-Man
Shieh, Wann-Yun
Liao, Yu-Fang
Hong, Hsiang-Hsi
Chang, Chung-Ta
author_sort Huang, Yi-Fang
collection PubMed
description BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.) are commonly used in clinics to evaluate treatment outcomes. The T-scan provides the relative bite force (%) compared to the maximal bite force on individual teeth or the unilateral arch. The DP2 can quantify occlusal force, measured in newtons (N), on the half arch or the overall bite, but it is difficult to identify the bite force on an individual tooth. It is difficult to select a device that fulfils all the requirements to record occlusal force. This study aimed to investigate the association between the bite measured by the DPS2 and T-scan to determine whether the measured bite force is comparable through calculation. METHODS: A total of 80 healthy adults, including 41 women and 39 men with a mean age of 38.2, were requested to bite pressure sensitive film sheets ten minutes apart. Linear regression analysis was used to estimate the measured bite force by the DP2 and T-scan. RESULTS: There was a significant positive correlation between the occlusal force measured by the DP2 and T-scan (P < 0.01) when intercept was equal to zero as confounders were adjused. These results provided the comparability of the measured occlusal forces determined by the DP2 and T-scan. CONCLUSION: The estimated bite force determined by DP2 and T-Scan is convertible using the linear equation from this study to increase the value for clinical applications. The estimated bite force from the two quantifiable occlusal indicators are comparable. The two commercially available quantifiable occlusal indicators can be fully adapted to all clinical requirements according to this result.
format Online
Article
Text
id pubmed-9636614
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-96366142022-11-06 The correlation between two occlusal analyzers for the measurement of bite force Huang, Yi-Fang Wang, Chin-Man Shieh, Wann-Yun Liao, Yu-Fang Hong, Hsiang-Hsi Chang, Chung-Ta BMC Oral Health Research BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.) are commonly used in clinics to evaluate treatment outcomes. The T-scan provides the relative bite force (%) compared to the maximal bite force on individual teeth or the unilateral arch. The DP2 can quantify occlusal force, measured in newtons (N), on the half arch or the overall bite, but it is difficult to identify the bite force on an individual tooth. It is difficult to select a device that fulfils all the requirements to record occlusal force. This study aimed to investigate the association between the bite measured by the DPS2 and T-scan to determine whether the measured bite force is comparable through calculation. METHODS: A total of 80 healthy adults, including 41 women and 39 men with a mean age of 38.2, were requested to bite pressure sensitive film sheets ten minutes apart. Linear regression analysis was used to estimate the measured bite force by the DP2 and T-scan. RESULTS: There was a significant positive correlation between the occlusal force measured by the DP2 and T-scan (P < 0.01) when intercept was equal to zero as confounders were adjused. These results provided the comparability of the measured occlusal forces determined by the DP2 and T-scan. CONCLUSION: The estimated bite force determined by DP2 and T-Scan is convertible using the linear equation from this study to increase the value for clinical applications. The estimated bite force from the two quantifiable occlusal indicators are comparable. The two commercially available quantifiable occlusal indicators can be fully adapted to all clinical requirements according to this result. BioMed Central 2022-11-05 /pmc/articles/PMC9636614/ /pubmed/36335336 http://dx.doi.org/10.1186/s12903-022-02484-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Huang, Yi-Fang
Wang, Chin-Man
Shieh, Wann-Yun
Liao, Yu-Fang
Hong, Hsiang-Hsi
Chang, Chung-Ta
The correlation between two occlusal analyzers for the measurement of bite force
title The correlation between two occlusal analyzers for the measurement of bite force
title_full The correlation between two occlusal analyzers for the measurement of bite force
title_fullStr The correlation between two occlusal analyzers for the measurement of bite force
title_full_unstemmed The correlation between two occlusal analyzers for the measurement of bite force
title_short The correlation between two occlusal analyzers for the measurement of bite force
title_sort correlation between two occlusal analyzers for the measurement of bite force
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9636614/
https://www.ncbi.nlm.nih.gov/pubmed/36335336
http://dx.doi.org/10.1186/s12903-022-02484-9
work_keys_str_mv AT huangyifang thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT wangchinman thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT shiehwannyun thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT liaoyufang thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT honghsianghsi thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT changchungta thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT huangyifang correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT wangchinman correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT shiehwannyun correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT liaoyufang correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT honghsianghsi correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce
AT changchungta correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce