Cargando…
The correlation between two occlusal analyzers for the measurement of bite force
BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9636614/ https://www.ncbi.nlm.nih.gov/pubmed/36335336 http://dx.doi.org/10.1186/s12903-022-02484-9 |
_version_ | 1784824984648024064 |
---|---|
author | Huang, Yi-Fang Wang, Chin-Man Shieh, Wann-Yun Liao, Yu-Fang Hong, Hsiang-Hsi Chang, Chung-Ta |
author_facet | Huang, Yi-Fang Wang, Chin-Man Shieh, Wann-Yun Liao, Yu-Fang Hong, Hsiang-Hsi Chang, Chung-Ta |
author_sort | Huang, Yi-Fang |
collection | PubMed |
description | BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.) are commonly used in clinics to evaluate treatment outcomes. The T-scan provides the relative bite force (%) compared to the maximal bite force on individual teeth or the unilateral arch. The DP2 can quantify occlusal force, measured in newtons (N), on the half arch or the overall bite, but it is difficult to identify the bite force on an individual tooth. It is difficult to select a device that fulfils all the requirements to record occlusal force. This study aimed to investigate the association between the bite measured by the DPS2 and T-scan to determine whether the measured bite force is comparable through calculation. METHODS: A total of 80 healthy adults, including 41 women and 39 men with a mean age of 38.2, were requested to bite pressure sensitive film sheets ten minutes apart. Linear regression analysis was used to estimate the measured bite force by the DP2 and T-scan. RESULTS: There was a significant positive correlation between the occlusal force measured by the DP2 and T-scan (P < 0.01) when intercept was equal to zero as confounders were adjused. These results provided the comparability of the measured occlusal forces determined by the DP2 and T-scan. CONCLUSION: The estimated bite force determined by DP2 and T-Scan is convertible using the linear equation from this study to increase the value for clinical applications. The estimated bite force from the two quantifiable occlusal indicators are comparable. The two commercially available quantifiable occlusal indicators can be fully adapted to all clinical requirements according to this result. |
format | Online Article Text |
id | pubmed-9636614 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-96366142022-11-06 The correlation between two occlusal analyzers for the measurement of bite force Huang, Yi-Fang Wang, Chin-Man Shieh, Wann-Yun Liao, Yu-Fang Hong, Hsiang-Hsi Chang, Chung-Ta BMC Oral Health Research BACKGROUND: Occlusal force represents masticatory function. Using quantifiable occlusal indicators provides a more objective occlusal force evaluation. In the recent dental practice, digital methods such as the Dental Prescale II (DP2, GC Corp., Tokyo, Japan) and T-scan (T-Scan III v8; Tekscan Inc.) are commonly used in clinics to evaluate treatment outcomes. The T-scan provides the relative bite force (%) compared to the maximal bite force on individual teeth or the unilateral arch. The DP2 can quantify occlusal force, measured in newtons (N), on the half arch or the overall bite, but it is difficult to identify the bite force on an individual tooth. It is difficult to select a device that fulfils all the requirements to record occlusal force. This study aimed to investigate the association between the bite measured by the DPS2 and T-scan to determine whether the measured bite force is comparable through calculation. METHODS: A total of 80 healthy adults, including 41 women and 39 men with a mean age of 38.2, were requested to bite pressure sensitive film sheets ten minutes apart. Linear regression analysis was used to estimate the measured bite force by the DP2 and T-scan. RESULTS: There was a significant positive correlation between the occlusal force measured by the DP2 and T-scan (P < 0.01) when intercept was equal to zero as confounders were adjused. These results provided the comparability of the measured occlusal forces determined by the DP2 and T-scan. CONCLUSION: The estimated bite force determined by DP2 and T-Scan is convertible using the linear equation from this study to increase the value for clinical applications. The estimated bite force from the two quantifiable occlusal indicators are comparable. The two commercially available quantifiable occlusal indicators can be fully adapted to all clinical requirements according to this result. BioMed Central 2022-11-05 /pmc/articles/PMC9636614/ /pubmed/36335336 http://dx.doi.org/10.1186/s12903-022-02484-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Huang, Yi-Fang Wang, Chin-Man Shieh, Wann-Yun Liao, Yu-Fang Hong, Hsiang-Hsi Chang, Chung-Ta The correlation between two occlusal analyzers for the measurement of bite force |
title | The correlation between two occlusal analyzers for the measurement of bite force |
title_full | The correlation between two occlusal analyzers for the measurement of bite force |
title_fullStr | The correlation between two occlusal analyzers for the measurement of bite force |
title_full_unstemmed | The correlation between two occlusal analyzers for the measurement of bite force |
title_short | The correlation between two occlusal analyzers for the measurement of bite force |
title_sort | correlation between two occlusal analyzers for the measurement of bite force |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9636614/ https://www.ncbi.nlm.nih.gov/pubmed/36335336 http://dx.doi.org/10.1186/s12903-022-02484-9 |
work_keys_str_mv | AT huangyifang thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT wangchinman thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT shiehwannyun thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT liaoyufang thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT honghsianghsi thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT changchungta thecorrelationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT huangyifang correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT wangchinman correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT shiehwannyun correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT liaoyufang correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT honghsianghsi correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce AT changchungta correlationbetweentwoocclusalanalyzersforthemeasurementofbiteforce |