Cargando…
The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500
BACKGROUND: To investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula. METHODS: We ret...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9637308/ https://www.ncbi.nlm.nih.gov/pubmed/36335303 http://dx.doi.org/10.1186/s12886-022-02644-z |
_version_ | 1784825157563449344 |
---|---|
author | Zhang, Di Yang, Meng Liu, Ziyuan Cai, Hongyuan Chen, Xiaoyong Zhang, Chun |
author_facet | Zhang, Di Yang, Meng Liu, Ziyuan Cai, Hongyuan Chen, Xiaoyong Zhang, Chun |
author_sort | Zhang, Di |
collection | PubMed |
description | BACKGROUND: To investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula. METHODS: We retrospectively enrolled patients who underwent ICL (EVO-V4c, STAAR Surgical Co. Nidau, Switzerland) implantation surgery from September 2020 to November 2021. The Pentacam-AXL and IOLMaster 500 biometers were used to measure axial length (AL), anterior chamber depth (ACD), keratometry (K), white to white (WTW), and central corneal thickness (CCT) values before and at least 2 months after ICL V4c implantation. The IOL power was calculated using the Barrett Universal II formula. RESULTS: The study included 45 eyes in 28 patients. There was a significant increase in ALs (average 0.03 ± 0.07 mm, p = 0.01) and a significant decrease of ACDs (average 0.19 ± 0.17 mm, p < 0.001) based on Pentacam-AXL. Similar changes in ALs and ACDs were also found in IOLMaster 500. In addition, the difference in WTWs in the two devices and that of CCTs in Pentacam-AXL were statistically significant. However, the preoperative and postoperative K1 and K2 were separately comparable using either device. The IOL power calculated by the Barrett Universal II formula did not change significantly either by the software built in Pentacam-AXL or by manually putting the parameters of the IOLMaster 500 into the formula manually (p = 0.058, p = 0.675, respectively). CONCLUSIONS: Ocular parameters including ALs, ACDs, WTWs, and CCTs using a new Pentacam-AXL and standard PCI-based IOLMaster 500 changed significantly before and after the ICL V4c implantation, while IOL power prediction using the Barrett Universal II formula was little affected. |
format | Online Article Text |
id | pubmed-9637308 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-96373082022-11-07 The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 Zhang, Di Yang, Meng Liu, Ziyuan Cai, Hongyuan Chen, Xiaoyong Zhang, Chun BMC Ophthalmol Research BACKGROUND: To investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula. METHODS: We retrospectively enrolled patients who underwent ICL (EVO-V4c, STAAR Surgical Co. Nidau, Switzerland) implantation surgery from September 2020 to November 2021. The Pentacam-AXL and IOLMaster 500 biometers were used to measure axial length (AL), anterior chamber depth (ACD), keratometry (K), white to white (WTW), and central corneal thickness (CCT) values before and at least 2 months after ICL V4c implantation. The IOL power was calculated using the Barrett Universal II formula. RESULTS: The study included 45 eyes in 28 patients. There was a significant increase in ALs (average 0.03 ± 0.07 mm, p = 0.01) and a significant decrease of ACDs (average 0.19 ± 0.17 mm, p < 0.001) based on Pentacam-AXL. Similar changes in ALs and ACDs were also found in IOLMaster 500. In addition, the difference in WTWs in the two devices and that of CCTs in Pentacam-AXL were statistically significant. However, the preoperative and postoperative K1 and K2 were separately comparable using either device. The IOL power calculated by the Barrett Universal II formula did not change significantly either by the software built in Pentacam-AXL or by manually putting the parameters of the IOLMaster 500 into the formula manually (p = 0.058, p = 0.675, respectively). CONCLUSIONS: Ocular parameters including ALs, ACDs, WTWs, and CCTs using a new Pentacam-AXL and standard PCI-based IOLMaster 500 changed significantly before and after the ICL V4c implantation, while IOL power prediction using the Barrett Universal II formula was little affected. BioMed Central 2022-11-05 /pmc/articles/PMC9637308/ /pubmed/36335303 http://dx.doi.org/10.1186/s12886-022-02644-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhang, Di Yang, Meng Liu, Ziyuan Cai, Hongyuan Chen, Xiaoyong Zhang, Chun The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title | The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title_full | The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title_fullStr | The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title_full_unstemmed | The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title_short | The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500 |
title_sort | effect of implantable collamer lens v4c on ocular biometric measurements and intraocular lens power calculation based on pentacam-axl and iolmaster 500 |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9637308/ https://www.ncbi.nlm.nih.gov/pubmed/36335303 http://dx.doi.org/10.1186/s12886-022-02644-z |
work_keys_str_mv | AT zhangdi theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT yangmeng theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT liuziyuan theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT caihongyuan theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT chenxiaoyong theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT zhangchun theeffectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT zhangdi effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT yangmeng effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT liuziyuan effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT caihongyuan effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT chenxiaoyong effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 AT zhangchun effectofimplantablecollamerlensv4conocularbiometricmeasurementsandintraocularlenspowercalculationbasedonpentacamaxlandiolmaster500 |