Cargando…
Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes
BACKGROUND: Although flash continuous glucose monitoring systems (FCGM) accuracy has been extensively studied in diabetes, its accuracy is still not fully evaluated in type 2 diabetes (T2D) patients in real-world settings. In the present study, we aim to assess the effects of diabetes complications...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639390/ https://www.ncbi.nlm.nih.gov/pubmed/36353669 http://dx.doi.org/10.2147/DMSO.S381565 |
_version_ | 1784825629056696320 |
---|---|
author | Wen, Xiaofang Zeng, Nan Zhang, Ningbo Ou, Tingting Li, Xiaowei Li, Xiaoying Li, Wangen Xu, Kang Du, Tao |
author_facet | Wen, Xiaofang Zeng, Nan Zhang, Ningbo Ou, Tingting Li, Xiaowei Li, Xiaoying Li, Wangen Xu, Kang Du, Tao |
author_sort | Wen, Xiaofang |
collection | PubMed |
description | BACKGROUND: Although flash continuous glucose monitoring systems (FCGM) accuracy has been extensively studied in diabetes, its accuracy is still not fully evaluated in type 2 diabetes (T2D) patients in real-world settings. In the present study, we aim to assess the effects of diabetes complications and related comorbidities on FCGM accuracy in T2D patients with diabetes complications and related comorbidities in the real world. METHODS: FCGM data were collected at eight-time points daily (3 AM, 7 AM, 9 AM, 11 AM, 1 PM, 5 PM, 7 PM, and 9 PM) from 742 patients with T2D and compared with simultaneous fingertip capillary blood glucose (reference blood glucose, REF), and the difference was evaluated using Parkes error grid (PEG), surveillance error grid (SEG), and logistic regression analysis. RESULTS: In total, 25,579 FCGM/REF data pairs were included in the study. The FCGM values were lower than the paired REF values in 75% of the pairs. The maximum bias (−23.0%) and maximum mean absolute relative difference (24.5%) were observed at 3 AM among eight-time points. SEG analysis also demonstrated the highest percentage of paired readings in moderate and great risk zone (C and D) at 3 AM than PEG analysis (7.33% vs 0.43%, P<0.001). According to the SEG classification, hypoglycemia, infection, diabetic foot, diabetic ketoacidosis, and hypertension were independent risk factors that impaired FCGM accuracy in patients. CONCLUSION: FCGM commonly underestimates blood glucose levels. Compared with PEG, SEG analysis seems more conducive to the analysis of FCGM performance. The present data highlights the impairment of diabetes complications and related comorbidities on the FCGM accuracy in T2D patients. |
format | Online Article Text |
id | pubmed-9639390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-96393902022-11-08 Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes Wen, Xiaofang Zeng, Nan Zhang, Ningbo Ou, Tingting Li, Xiaowei Li, Xiaoying Li, Wangen Xu, Kang Du, Tao Diabetes Metab Syndr Obes Original Research BACKGROUND: Although flash continuous glucose monitoring systems (FCGM) accuracy has been extensively studied in diabetes, its accuracy is still not fully evaluated in type 2 diabetes (T2D) patients in real-world settings. In the present study, we aim to assess the effects of diabetes complications and related comorbidities on FCGM accuracy in T2D patients with diabetes complications and related comorbidities in the real world. METHODS: FCGM data were collected at eight-time points daily (3 AM, 7 AM, 9 AM, 11 AM, 1 PM, 5 PM, 7 PM, and 9 PM) from 742 patients with T2D and compared with simultaneous fingertip capillary blood glucose (reference blood glucose, REF), and the difference was evaluated using Parkes error grid (PEG), surveillance error grid (SEG), and logistic regression analysis. RESULTS: In total, 25,579 FCGM/REF data pairs were included in the study. The FCGM values were lower than the paired REF values in 75% of the pairs. The maximum bias (−23.0%) and maximum mean absolute relative difference (24.5%) were observed at 3 AM among eight-time points. SEG analysis also demonstrated the highest percentage of paired readings in moderate and great risk zone (C and D) at 3 AM than PEG analysis (7.33% vs 0.43%, P<0.001). According to the SEG classification, hypoglycemia, infection, diabetic foot, diabetic ketoacidosis, and hypertension were independent risk factors that impaired FCGM accuracy in patients. CONCLUSION: FCGM commonly underestimates blood glucose levels. Compared with PEG, SEG analysis seems more conducive to the analysis of FCGM performance. The present data highlights the impairment of diabetes complications and related comorbidities on the FCGM accuracy in T2D patients. Dove 2022-11-03 /pmc/articles/PMC9639390/ /pubmed/36353669 http://dx.doi.org/10.2147/DMSO.S381565 Text en © 2022 Wen et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Wen, Xiaofang Zeng, Nan Zhang, Ningbo Ou, Tingting Li, Xiaowei Li, Xiaoying Li, Wangen Xu, Kang Du, Tao Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title | Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title_full | Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title_fullStr | Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title_full_unstemmed | Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title_short | Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes |
title_sort | diabetes complications and related comorbidities impair the accuracy of freestyle libre, a flash continuous glucose monitoring system, in patients with type 2 diabetes |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639390/ https://www.ncbi.nlm.nih.gov/pubmed/36353669 http://dx.doi.org/10.2147/DMSO.S381565 |
work_keys_str_mv | AT wenxiaofang diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT zengnan diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT zhangningbo diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT outingting diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT lixiaowei diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT lixiaoying diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT liwangen diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT xukang diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes AT dutao diabetescomplicationsandrelatedcomorbiditiesimpairtheaccuracyoffreestylelibreaflashcontinuousglucosemonitoringsysteminpatientswithtype2diabetes |