A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management

Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here,...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yiqun, Yu, Qi, Luo, Xiaojin, Ye, Le, Yang, Li, Cui, Yue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AAAS 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639446/
https://www.ncbi.nlm.nih.gov/pubmed/36349339
http://dx.doi.org/10.34133/2022/9870637
_version_ 1784825643250221056
author Liu, Yiqun
Yu, Qi
Luo, Xiaojin
Ye, Le
Yang, Li
Cui, Yue
author_facet Liu, Yiqun
Yu, Qi
Luo, Xiaojin
Ye, Le
Yang, Li
Cui, Yue
author_sort Liu, Yiqun
collection PubMed
description Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here, we present for the first time a microtube-based wearable closed-loop minisystem for diabetes management. The closed-loop minisystem includes a biosensing device, an electroosmotic micropump, and a printed circuit board (PCB) with an algorithm. The microtube-based sensing device coated on the outer surface of the microtube is inserted into subcutaneous tissue for detecting interstitial glucose; the current signal for sensing glucose is processed by the PCB to power the electroosmotic micropump intelligently for the delivery of insulin into the subcutaneous tissue via the microtube channel. The closed-loop minisystem worn on a diabetic SD rat can successfully maintain its blood glucose level within a safe level. It is expected that this new closed-loop paradigm could open up new prospects for clinical diabetes management.
format Online
Article
Text
id pubmed-9639446
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher AAAS
record_format MEDLINE/PubMed
spelling pubmed-96394462022-11-07 A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management Liu, Yiqun Yu, Qi Luo, Xiaojin Ye, Le Yang, Li Cui, Yue Research (Wash D C) Research Article Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here, we present for the first time a microtube-based wearable closed-loop minisystem for diabetes management. The closed-loop minisystem includes a biosensing device, an electroosmotic micropump, and a printed circuit board (PCB) with an algorithm. The microtube-based sensing device coated on the outer surface of the microtube is inserted into subcutaneous tissue for detecting interstitial glucose; the current signal for sensing glucose is processed by the PCB to power the electroosmotic micropump intelligently for the delivery of insulin into the subcutaneous tissue via the microtube channel. The closed-loop minisystem worn on a diabetic SD rat can successfully maintain its blood glucose level within a safe level. It is expected that this new closed-loop paradigm could open up new prospects for clinical diabetes management. AAAS 2022-10-25 /pmc/articles/PMC9639446/ /pubmed/36349339 http://dx.doi.org/10.34133/2022/9870637 Text en Copyright © 2022 Yiqun Liu et al. https://creativecommons.org/licenses/by/4.0/Exclusive Licensee Science and Technology Review Publishing House. Distributed under a Creative Commons Attribution License (CC BY 4.0).
spellingShingle Research Article
Liu, Yiqun
Yu, Qi
Luo, Xiaojin
Ye, Le
Yang, Li
Cui, Yue
A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title_full A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title_fullStr A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title_full_unstemmed A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title_short A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
title_sort microtube-based wearable closed-loop minisystem for diabetes management
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639446/
https://www.ncbi.nlm.nih.gov/pubmed/36349339
http://dx.doi.org/10.34133/2022/9870637
work_keys_str_mv AT liuyiqun amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yuqi amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT luoxiaojin amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yele amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yangli amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT cuiyue amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement
AT liuyiqun microtubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yuqi microtubebasedwearableclosedloopminisystemfordiabetesmanagement
AT luoxiaojin microtubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yele microtubebasedwearableclosedloopminisystemfordiabetesmanagement
AT yangli microtubebasedwearableclosedloopminisystemfordiabetesmanagement
AT cuiyue microtubebasedwearableclosedloopminisystemfordiabetesmanagement