A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management
Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AAAS
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639446/ https://www.ncbi.nlm.nih.gov/pubmed/36349339 http://dx.doi.org/10.34133/2022/9870637 |
_version_ | 1784825643250221056 |
---|---|
author | Liu, Yiqun Yu, Qi Luo, Xiaojin Ye, Le Yang, Li Cui, Yue |
author_facet | Liu, Yiqun Yu, Qi Luo, Xiaojin Ye, Le Yang, Li Cui, Yue |
author_sort | Liu, Yiqun |
collection | PubMed |
description | Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here, we present for the first time a microtube-based wearable closed-loop minisystem for diabetes management. The closed-loop minisystem includes a biosensing device, an electroosmotic micropump, and a printed circuit board (PCB) with an algorithm. The microtube-based sensing device coated on the outer surface of the microtube is inserted into subcutaneous tissue for detecting interstitial glucose; the current signal for sensing glucose is processed by the PCB to power the electroosmotic micropump intelligently for the delivery of insulin into the subcutaneous tissue via the microtube channel. The closed-loop minisystem worn on a diabetic SD rat can successfully maintain its blood glucose level within a safe level. It is expected that this new closed-loop paradigm could open up new prospects for clinical diabetes management. |
format | Online Article Text |
id | pubmed-9639446 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AAAS |
record_format | MEDLINE/PubMed |
spelling | pubmed-96394462022-11-07 A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management Liu, Yiqun Yu, Qi Luo, Xiaojin Ye, Le Yang, Li Cui, Yue Research (Wash D C) Research Article Diabetes is a chronic metabolic disease with a high blood glucose level, leading to both seriously acute and chronic complications. The closed-loop system is an ideal system for diabetes management. However, the large size and high cost of the commercial systems restrict their widespread uses. Here, we present for the first time a microtube-based wearable closed-loop minisystem for diabetes management. The closed-loop minisystem includes a biosensing device, an electroosmotic micropump, and a printed circuit board (PCB) with an algorithm. The microtube-based sensing device coated on the outer surface of the microtube is inserted into subcutaneous tissue for detecting interstitial glucose; the current signal for sensing glucose is processed by the PCB to power the electroosmotic micropump intelligently for the delivery of insulin into the subcutaneous tissue via the microtube channel. The closed-loop minisystem worn on a diabetic SD rat can successfully maintain its blood glucose level within a safe level. It is expected that this new closed-loop paradigm could open up new prospects for clinical diabetes management. AAAS 2022-10-25 /pmc/articles/PMC9639446/ /pubmed/36349339 http://dx.doi.org/10.34133/2022/9870637 Text en Copyright © 2022 Yiqun Liu et al. https://creativecommons.org/licenses/by/4.0/Exclusive Licensee Science and Technology Review Publishing House. Distributed under a Creative Commons Attribution License (CC BY 4.0). |
spellingShingle | Research Article Liu, Yiqun Yu, Qi Luo, Xiaojin Ye, Le Yang, Li Cui, Yue A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title | A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title_full | A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title_fullStr | A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title_full_unstemmed | A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title_short | A Microtube-Based Wearable Closed-Loop Minisystem for Diabetes Management |
title_sort | microtube-based wearable closed-loop minisystem for diabetes management |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9639446/ https://www.ncbi.nlm.nih.gov/pubmed/36349339 http://dx.doi.org/10.34133/2022/9870637 |
work_keys_str_mv | AT liuyiqun amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT yuqi amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT luoxiaojin amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT yele amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT yangli amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT cuiyue amicrotubebasedwearableclosedloopminisystemfordiabetesmanagement AT liuyiqun microtubebasedwearableclosedloopminisystemfordiabetesmanagement AT yuqi microtubebasedwearableclosedloopminisystemfordiabetesmanagement AT luoxiaojin microtubebasedwearableclosedloopminisystemfordiabetesmanagement AT yele microtubebasedwearableclosedloopminisystemfordiabetesmanagement AT yangli microtubebasedwearableclosedloopminisystemfordiabetesmanagement AT cuiyue microtubebasedwearableclosedloopminisystemfordiabetesmanagement |