Cargando…

Predictors and long-term outcomes of heart block after transcatheter device closure of perimembranous ventricular septal defect

BACKGROUND: Heart block is the most common and concerning complication associated with transcatheter device closure of perimembranous ventricular septal defect (pmVSD) and its occurrence remains a great challenge for device closure. METHODS: Between June 2002 and June 2020, 1076 pediatric patients w...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Diandong, Zhang, Simiao, Zhang, Yuxin, Lv, Jianli, Yi, Yingchun, Wang, Jing, Wang, Yan, Yang, Xiaofei, Zhang, Jianjun, Han, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9640380/
https://www.ncbi.nlm.nih.gov/pubmed/36386314
http://dx.doi.org/10.3389/fcvm.2022.1041852
Descripción
Sumario:BACKGROUND: Heart block is the most common and concerning complication associated with transcatheter device closure of perimembranous ventricular septal defect (pmVSD) and its occurrence remains a great challenge for device closure. METHODS: Between June 2002 and June 2020, 1076 pediatric patients with pmVSD, who successfully underwent transcatheter device closure in our center, were enrolled in this cohort study, with a median follow-up of 64 months (range: 1 to 19 years). RESULTS: Of 1076 patients, 234 (21.8%) developed postprocedural heart block, with right bundle branch block being the most common (74.8%), followed by left bundle branch block (16.2%), and atrioventricular block (5.6%). Complete atrioventricular block occurred in 5 cases, including 3 cases with permanent pacemaker implantation, 1 case with recovery to normal sinus rhythm, and 1 case with sudden cardiac death. Most patients (97.9%) developed heart block within 1 week of procedure. Finally, 138 cases returned to normal cardiac conduction. Multivariate logistic regression revealed that thin-waist occluders (odds ratio [OR]: 1.759; 95% confidence interval [CI]: 1.023 to 3.022; P = 0.041), and oversized devices (OR: 1.809; 95% CI: 1.322 to 2.476; P < 0.001) were independently associated with occurrence of postprocedural heart block. Moreover, heart block was less likely to occur when the left disk of occluder was placed within the aneurysmal tissue (OR: 0.568; 95% CI: 0.348 to 0.928; P = 0.024). CONCLUSION: The outcome of postprocedural heart block is favorable in most cases. Oversized devices and thin-waist occluders should be avoided. Placement of the left disk of the device should into the aneurysmal tissue is highly recommended.