Cargando…

Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure

BACKGROUND: A short instrument would enhance the viability of a study. Therefore, we aimed to shorten the specific module (SPD-10) of the Quality of Life Instrument for Chronic Diseases - Chronic Renal Failure (QLICD-CRF) for assessing the quality of life of patients with chronic renal failure. METH...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Zhengqin, Liu, Yuxi, Fong, Daniel Yee-Tak, Huang, Xinping, Weng, Min, Wan, Chonghua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9641813/
https://www.ncbi.nlm.nih.gov/pubmed/36348284
http://dx.doi.org/10.1186/s12874-022-01766-8
_version_ 1784826165263859712
author Xiao, Zhengqin
Liu, Yuxi
Fong, Daniel Yee-Tak
Huang, Xinping
Weng, Min
Wan, Chonghua
author_facet Xiao, Zhengqin
Liu, Yuxi
Fong, Daniel Yee-Tak
Huang, Xinping
Weng, Min
Wan, Chonghua
author_sort Xiao, Zhengqin
collection PubMed
description BACKGROUND: A short instrument would enhance the viability of a study. Therefore, we aimed to shorten the specific module (SPD-10) of the Quality of Life Instrument for Chronic Diseases - Chronic Renal Failure (QLICD-CRF) for assessing the quality of life of patients with chronic renal failure. METHODS: The 10-item SPD-10 was self-administered to 164 patients with chronic renal failure. A shortened form was first obtained by a tandem use of the classical test theory (CTT), the generalizability theory (GT), and the item response theory (IRT). In addition, we also shortened the SPD-10 by the Optimal Test Assembly (OTA). RESULTS: Both the tandem use of GT, CTT and IRT, and the OTA derived the same 7-item shortened version (SPD-7). It included items CRF1, CRF2, CRF3, CRF4, CRF6, CRF8, and CRF9 of the SPD-10. The SPD-7 had a Cronbach alpha of 0.78. The correlation coefficients of its total and factor scores with those of the SPD-10 were 0.96 and 0.98, respectively. Confirmatory factor analysis confirmed the unidimensional structure of the SPD-7, with the comparative fit index=0.96, the Tucker-Lewis index=0.94, and the root mean square error of approximation=0.09. CONCLUSION: The short-form SPD-7 is reliable and valid for assessing the impact of clinical symptoms and side effects on the quality of life of patients with chronic renal failure. It is an efficient option without compromising the measurement performance of the SPD-10.
format Online
Article
Text
id pubmed-9641813
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-96418132022-11-15 Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure Xiao, Zhengqin Liu, Yuxi Fong, Daniel Yee-Tak Huang, Xinping Weng, Min Wan, Chonghua BMC Med Res Methodol Research BACKGROUND: A short instrument would enhance the viability of a study. Therefore, we aimed to shorten the specific module (SPD-10) of the Quality of Life Instrument for Chronic Diseases - Chronic Renal Failure (QLICD-CRF) for assessing the quality of life of patients with chronic renal failure. METHODS: The 10-item SPD-10 was self-administered to 164 patients with chronic renal failure. A shortened form was first obtained by a tandem use of the classical test theory (CTT), the generalizability theory (GT), and the item response theory (IRT). In addition, we also shortened the SPD-10 by the Optimal Test Assembly (OTA). RESULTS: Both the tandem use of GT, CTT and IRT, and the OTA derived the same 7-item shortened version (SPD-7). It included items CRF1, CRF2, CRF3, CRF4, CRF6, CRF8, and CRF9 of the SPD-10. The SPD-7 had a Cronbach alpha of 0.78. The correlation coefficients of its total and factor scores with those of the SPD-10 were 0.96 and 0.98, respectively. Confirmatory factor analysis confirmed the unidimensional structure of the SPD-7, with the comparative fit index=0.96, the Tucker-Lewis index=0.94, and the root mean square error of approximation=0.09. CONCLUSION: The short-form SPD-7 is reliable and valid for assessing the impact of clinical symptoms and side effects on the quality of life of patients with chronic renal failure. It is an efficient option without compromising the measurement performance of the SPD-10. BioMed Central 2022-11-08 /pmc/articles/PMC9641813/ /pubmed/36348284 http://dx.doi.org/10.1186/s12874-022-01766-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Xiao, Zhengqin
Liu, Yuxi
Fong, Daniel Yee-Tak
Huang, Xinping
Weng, Min
Wan, Chonghua
Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title_full Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title_fullStr Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title_full_unstemmed Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title_short Short-form development of the specific module of the QLICD-CRF(V2.0) for assessing the quality of life of patients with chronic renal failure
title_sort short-form development of the specific module of the qlicd-crf(v2.0) for assessing the quality of life of patients with chronic renal failure
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9641813/
https://www.ncbi.nlm.nih.gov/pubmed/36348284
http://dx.doi.org/10.1186/s12874-022-01766-8
work_keys_str_mv AT xiaozhengqin shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure
AT liuyuxi shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure
AT fongdanielyeetak shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure
AT huangxinping shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure
AT wengmin shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure
AT wanchonghua shortformdevelopmentofthespecificmoduleoftheqlicdcrfv20forassessingthequalityoflifeofpatientswithchronicrenalfailure