Cargando…
Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea
BACKGROUND: Lateral parapharyngeal wall (LPW) thickness is a potentially useful anatomical marker of childhood obstructive sleep apnea (OSA). Measuring LPW thickness by ultrasonography (USG) is technically feasible but its use in children has not been validated. Therefore, this study aimed to assess...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9642859/ https://www.ncbi.nlm.nih.gov/pubmed/36394067 http://dx.doi.org/10.2147/NSS.S369727 |
_version_ | 1784826400486719488 |
---|---|
author | Yuen, Hoi Man Lai, Andy C Y Liu, Eric K H Lee, Ming Chung Chu, Winnie C W Chan, Joey W Y Chan, Ngan Yin Wing, Yun Kwok Li, Albert M Chan, Kate C Au, Chun Ting |
author_facet | Yuen, Hoi Man Lai, Andy C Y Liu, Eric K H Lee, Ming Chung Chu, Winnie C W Chan, Joey W Y Chan, Ngan Yin Wing, Yun Kwok Li, Albert M Chan, Kate C Au, Chun Ting |
author_sort | Yuen, Hoi Man |
collection | PubMed |
description | BACKGROUND: Lateral parapharyngeal wall (LPW) thickness is a potentially useful anatomical marker of childhood obstructive sleep apnea (OSA). Measuring LPW thickness by ultrasonography (USG) is technically feasible but its use in children has not been validated. Therefore, this study aimed to assess the intra- and inter-operator reliability of the sonographic measurements of LPW thickness in children and to assess its validity against magnetic resonance imaging (MRI) measurements. METHODS: Prepubertal children aged 6–11 years suspected to suffer from OSA were recruited. Repeated measurements of LPW thickness by USG were conducted to evaluate the intra- and inter-operator reliability, examined by intraclass correlation coefficient (ICC). LPW thickness was measured as the distance between the internal carotid artery and the echogenic surface of the pharynx in an oblique coronal plane by USG. LPW thickness was measured by MRI at the retropalatal level. The agreement between the LPW thickness measured by USG and MRI was assessed by ICC and Bland-Altman plot. RESULTS: Thirty-four children (mean age: 8.66 ± 1.61, 26 male) were recruited. The intra- and inter-operator reliability of the LPW thickness by USG was good (ICC = 0.84 and 0.82, respectively). The agreement between the USG-measured and MRI-measured LPW thickness was moderate (ICC = 0.72). he Bland-Altman plot demonstrated a mean difference of 0.061 cm and a 95% limit of agreement from 0.91 to 1.12 cm. CONCLUSION: In this study, we demonstrated that ultrasonography is a valid and reliable method to assess LPW thickness in children. This study was supported by the Direct Grant for Research from the Research Committee of the Chinese University of Hong Kong (Project no. 2020.073). |
format | Online Article Text |
id | pubmed-9642859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-96428592022-11-15 Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea Yuen, Hoi Man Lai, Andy C Y Liu, Eric K H Lee, Ming Chung Chu, Winnie C W Chan, Joey W Y Chan, Ngan Yin Wing, Yun Kwok Li, Albert M Chan, Kate C Au, Chun Ting Nat Sci Sleep Original Research BACKGROUND: Lateral parapharyngeal wall (LPW) thickness is a potentially useful anatomical marker of childhood obstructive sleep apnea (OSA). Measuring LPW thickness by ultrasonography (USG) is technically feasible but its use in children has not been validated. Therefore, this study aimed to assess the intra- and inter-operator reliability of the sonographic measurements of LPW thickness in children and to assess its validity against magnetic resonance imaging (MRI) measurements. METHODS: Prepubertal children aged 6–11 years suspected to suffer from OSA were recruited. Repeated measurements of LPW thickness by USG were conducted to evaluate the intra- and inter-operator reliability, examined by intraclass correlation coefficient (ICC). LPW thickness was measured as the distance between the internal carotid artery and the echogenic surface of the pharynx in an oblique coronal plane by USG. LPW thickness was measured by MRI at the retropalatal level. The agreement between the LPW thickness measured by USG and MRI was assessed by ICC and Bland-Altman plot. RESULTS: Thirty-four children (mean age: 8.66 ± 1.61, 26 male) were recruited. The intra- and inter-operator reliability of the LPW thickness by USG was good (ICC = 0.84 and 0.82, respectively). The agreement between the USG-measured and MRI-measured LPW thickness was moderate (ICC = 0.72). he Bland-Altman plot demonstrated a mean difference of 0.061 cm and a 95% limit of agreement from 0.91 to 1.12 cm. CONCLUSION: In this study, we demonstrated that ultrasonography is a valid and reliable method to assess LPW thickness in children. This study was supported by the Direct Grant for Research from the Research Committee of the Chinese University of Hong Kong (Project no. 2020.073). Dove 2022-11-04 /pmc/articles/PMC9642859/ /pubmed/36394067 http://dx.doi.org/10.2147/NSS.S369727 Text en © 2022 Yuen et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Yuen, Hoi Man Lai, Andy C Y Liu, Eric K H Lee, Ming Chung Chu, Winnie C W Chan, Joey W Y Chan, Ngan Yin Wing, Yun Kwok Li, Albert M Chan, Kate C Au, Chun Ting Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title | Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title_full | Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title_fullStr | Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title_full_unstemmed | Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title_short | Validation of the Sonographic Measurement of Lateral Parapharyngeal Wall Thickness in Childhood Obstructive Sleep Apnea |
title_sort | validation of the sonographic measurement of lateral parapharyngeal wall thickness in childhood obstructive sleep apnea |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9642859/ https://www.ncbi.nlm.nih.gov/pubmed/36394067 http://dx.doi.org/10.2147/NSS.S369727 |
work_keys_str_mv | AT yuenhoiman validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT laiandycy validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT liuerickh validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT leemingchung validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT chuwinniecw validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT chanjoeywy validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT channganyin validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT wingyunkwok validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT lialbertm validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT chankatec validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea AT auchunting validationofthesonographicmeasurementoflateralparapharyngealwallthicknessinchildhoodobstructivesleepapnea |