Cargando…

Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters

This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO(2)) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted hum...

Descripción completa

Detalles Bibliográficos
Autores principales: Henriques, Dilma Helena Neves, Alves, Ana Maria Hecke, Kuntze, Morgane Marion, Garcia, Lucas da Fonseca Roberti, Bortoluzzi, Eduardo Antunes, Teixeira, Cleonice da Silveira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645166/
https://www.ncbi.nlm.nih.gov/pubmed/36287496
http://dx.doi.org/10.1590/0103-6440202204903
_version_ 1784826908633989120
author Henriques, Dilma Helena Neves
Alves, Ana Maria Hecke
Kuntze, Morgane Marion
Garcia, Lucas da Fonseca Roberti
Bortoluzzi, Eduardo Antunes
Teixeira, Cleonice da Silveira
author_facet Henriques, Dilma Helena Neves
Alves, Ana Maria Hecke
Kuntze, Morgane Marion
Garcia, Lucas da Fonseca Roberti
Bortoluzzi, Eduardo Antunes
Teixeira, Cleonice da Silveira
author_sort Henriques, Dilma Helena Neves
collection PubMed
description This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO(2)) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted human teeth had their crowns interposed between the POs and an optical simulator, which emulated the SpO(2) and heart beats per minute (bpm) at HP (100% SpO(2)/75 bpm) and LP (86% SpO(2)/75 bpm) modes. Afterwards, the palatine/lingual surfaces of the dental crowns were worn with diamond drills. The reading of SpO(2) was performed again using the POs alternately through the buccal surface of each dental crown. Data were analyzed by the Wilcoxon, Mann-Whitney and Kendall Tau-b tests (α=5%). The results showed significant difference at the HP and LP modes in the SpO(2) readouts through the different dental thicknesses with the use of BCI, and at the LP mode with the use of Sense 10, which had a significant linear correlation (p<0.0001) and lower SpO(2) readout values in relation to the increase of the dental thickness. Irrespective of tooth thickness, Sense 10 had significantly higher readout values (p<0.0001) than BCI at both perfusion modes. The interposition of different thicknesses of enamel and dentin influenced the POs measurement of SpO(2,) specially at the low perfusion mode. The POs were more accurate in SpO(2) measurement when simulated perfusion levels were higher.
format Online
Article
Text
id pubmed-9645166
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-96451662022-11-14 Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters Henriques, Dilma Helena Neves Alves, Ana Maria Hecke Kuntze, Morgane Marion Garcia, Lucas da Fonseca Roberti Bortoluzzi, Eduardo Antunes Teixeira, Cleonice da Silveira Braz Dent J Article This study aimed to evaluate the influence of different dental tissue thickness on the measurement of oxygen saturation (SpO(2)) levels in high (HP) and low (LP) blood perfusion by comparing the values obtained from two different pulse oximeters (POs) - BCI and Sense 10. Thirty freshly extracted human teeth had their crowns interposed between the POs and an optical simulator, which emulated the SpO(2) and heart beats per minute (bpm) at HP (100% SpO(2)/75 bpm) and LP (86% SpO(2)/75 bpm) modes. Afterwards, the palatine/lingual surfaces of the dental crowns were worn with diamond drills. The reading of SpO(2) was performed again using the POs alternately through the buccal surface of each dental crown. Data were analyzed by the Wilcoxon, Mann-Whitney and Kendall Tau-b tests (α=5%). The results showed significant difference at the HP and LP modes in the SpO(2) readouts through the different dental thicknesses with the use of BCI, and at the LP mode with the use of Sense 10, which had a significant linear correlation (p<0.0001) and lower SpO(2) readout values in relation to the increase of the dental thickness. Irrespective of tooth thickness, Sense 10 had significantly higher readout values (p<0.0001) than BCI at both perfusion modes. The interposition of different thicknesses of enamel and dentin influenced the POs measurement of SpO(2,) specially at the low perfusion mode. The POs were more accurate in SpO(2) measurement when simulated perfusion levels were higher. Fundação Odontológica de Ribeirão Preto 2022-10-21 /pmc/articles/PMC9645166/ /pubmed/36287496 http://dx.doi.org/10.1590/0103-6440202204903 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Henriques, Dilma Helena Neves
Alves, Ana Maria Hecke
Kuntze, Morgane Marion
Garcia, Lucas da Fonseca Roberti
Bortoluzzi, Eduardo Antunes
Teixeira, Cleonice da Silveira
Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title_full Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title_fullStr Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title_full_unstemmed Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title_short Effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
title_sort effect of dental tissue thickness on the measurement of oxygen saturation by two different pulse oximeters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645166/
https://www.ncbi.nlm.nih.gov/pubmed/36287496
http://dx.doi.org/10.1590/0103-6440202204903
work_keys_str_mv AT henriquesdilmahelenaneves effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters
AT alvesanamariahecke effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters
AT kuntzemorganemarion effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters
AT garcialucasdafonsecaroberti effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters
AT bortoluzzieduardoantunes effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters
AT teixeiracleonicedasilveira effectofdentaltissuethicknessonthemeasurementofoxygensaturationbytwodifferentpulseoximeters