Cargando…

Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone

The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Lima, Julia Raulino, Bernardino, Sttephany Silva, Pereira, Lucas De Sousa Goulart, Pignaton, Túlio Bonna, Spin-Neto, Rubens, Marcantonio-Junior, Elcio, Oliveira, Guilherme José Pimentel Lopes De
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645177/
https://www.ncbi.nlm.nih.gov/pubmed/36043567
http://dx.doi.org/10.1590/0103-6440202204823
_version_ 1784826911337218048
author Lima, Julia Raulino
Bernardino, Sttephany Silva
Pereira, Lucas De Sousa Goulart
Pignaton, Túlio Bonna
Spin-Neto, Rubens
Marcantonio-Junior, Elcio
Oliveira, Guilherme José Pimentel Lopes De
author_facet Lima, Julia Raulino
Bernardino, Sttephany Silva
Pereira, Lucas De Sousa Goulart
Pignaton, Túlio Bonna
Spin-Neto, Rubens
Marcantonio-Junior, Elcio
Oliveira, Guilherme José Pimentel Lopes De
author_sort Lima, Julia Raulino
collection PubMed
description The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB.
format Online
Article
Text
id pubmed-9645177
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-96451772022-11-14 Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone Lima, Julia Raulino Bernardino, Sttephany Silva Pereira, Lucas De Sousa Goulart Pignaton, Túlio Bonna Spin-Neto, Rubens Marcantonio-Junior, Elcio Oliveira, Guilherme José Pimentel Lopes De Braz Dent J Article The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB. Fundação Odontológica de Ribeirão Preto 2022-08-26 /pmc/articles/PMC9645177/ /pubmed/36043567 http://dx.doi.org/10.1590/0103-6440202204823 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Lima, Julia Raulino
Bernardino, Sttephany Silva
Pereira, Lucas De Sousa Goulart
Pignaton, Túlio Bonna
Spin-Neto, Rubens
Marcantonio-Junior, Elcio
Oliveira, Guilherme José Pimentel Lopes De
Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title_full Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title_fullStr Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title_full_unstemmed Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title_short Effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
title_sort effect of different thresholds on the accuracy of linear and volumetric analysis of native- and grafted-bone
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645177/
https://www.ncbi.nlm.nih.gov/pubmed/36043567
http://dx.doi.org/10.1590/0103-6440202204823
work_keys_str_mv AT limajuliaraulino effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT bernardinosttephanysilva effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT pereiralucasdesousagoulart effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT pignatontuliobonna effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT spinnetorubens effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT marcantoniojuniorelcio effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone
AT oliveiraguilhermejosepimentellopesde effectofdifferentthresholdsontheaccuracyoflinearandvolumetricanalysisofnativeandgraftedbone