Cargando…

Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT

PURPOSE: To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). METHODS: In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured v...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Fang, Xia, Fei, Niu, Lingling, Zhao, Jing, Wang, Xiaoying, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645365/
https://www.ncbi.nlm.nih.gov/pubmed/36331273
http://dx.doi.org/10.1167/tvst.11.11.4
_version_ 1784826951984218112
author Liu, Fang
Xia, Fei
Niu, Lingling
Zhao, Jing
Wang, Xiaoying
Zhou, Xingtao
author_facet Liu, Fang
Xia, Fei
Niu, Lingling
Zhao, Jing
Wang, Xiaoying
Zhou, Xingtao
author_sort Liu, Fang
collection PubMed
description PURPOSE: To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). METHODS: In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal–temporal (0°–180°), superior–inferior (90°–270°), and superior nasal–inferior temporal (80°–260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular–iris space area at 500 µm (TISA500), trabecular–iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular–iris circumference volume at 500 µm (TICV500), and the index and area of iris–trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. RESULTS: The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm(2) to 12.343% ± 13.216% and 0.903 ± 1.304 mm(2) (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior–nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. CONCLUSIONS: Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior–nasal and superior quadrants. TRANSLATIONAL RELEVANCE: We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.
format Online
Article
Text
id pubmed-9645365
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-96453652022-11-15 Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT Liu, Fang Xia, Fei Niu, Lingling Zhao, Jing Wang, Xiaoying Zhou, Xingtao Transl Vis Sci Technol Clinical Trials PURPOSE: To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). METHODS: In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal–temporal (0°–180°), superior–inferior (90°–270°), and superior nasal–inferior temporal (80°–260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular–iris space area at 500 µm (TISA500), trabecular–iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular–iris circumference volume at 500 µm (TICV500), and the index and area of iris–trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. RESULTS: The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm(2) to 12.343% ± 13.216% and 0.903 ± 1.304 mm(2) (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior–nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. CONCLUSIONS: Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior–nasal and superior quadrants. TRANSLATIONAL RELEVANCE: We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery. The Association for Research in Vision and Ophthalmology 2022-11-04 /pmc/articles/PMC9645365/ /pubmed/36331273 http://dx.doi.org/10.1167/tvst.11.11.4 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Clinical Trials
Liu, Fang
Xia, Fei
Niu, Lingling
Zhao, Jing
Wang, Xiaoying
Zhou, Xingtao
Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title_full Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title_fullStr Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title_full_unstemmed Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title_short Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
title_sort early assessment of circumferential anterior segment structures following implantable collamer lens v4c implantation via ss-oct
topic Clinical Trials
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645365/
https://www.ncbi.nlm.nih.gov/pubmed/36331273
http://dx.doi.org/10.1167/tvst.11.11.4
work_keys_str_mv AT liufang earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct
AT xiafei earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct
AT niulingling earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct
AT zhaojing earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct
AT wangxiaoying earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct
AT zhouxingtao earlyassessmentofcircumferentialanteriorsegmentstructuresfollowingimplantablecollamerlensv4cimplantationviassoct