Cargando…

Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort

PURPOSE: To investigate and evaluate the value of thoracic low dose computed tomography (LDCT) scan in the diagnosis of anemia. MATERIALS AND METHODS: 661 patients who received thoracic computed tomography (CT) examination and underwent a peripheral blood examination were retrospectively included. 3...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jianing, Wu, Minghao, Huang, Jinchao, Li, Shixia, Ye, Zhaoxiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645455/
https://www.ncbi.nlm.nih.gov/pubmed/36386355
http://dx.doi.org/10.3389/fcvm.2022.987753
_version_ 1784826967608000512
author Zhang, Jianing
Wu, Minghao
Huang, Jinchao
Li, Shixia
Ye, Zhaoxiang
author_facet Zhang, Jianing
Wu, Minghao
Huang, Jinchao
Li, Shixia
Ye, Zhaoxiang
author_sort Zhang, Jianing
collection PubMed
description PURPOSE: To investigate and evaluate the value of thoracic low dose computed tomography (LDCT) scan in the diagnosis of anemia. MATERIALS AND METHODS: 661 patients who received thoracic computed tomography (CT) examination and underwent a peripheral blood examination were retrospectively included. 341 patients underwent conventional dose CT (CDCT), and 320 patients underwent LDCT. Regions of interest (ROI) were placed on the left ventricular cavity (LV), descending aorta (DAo), and interventricular septum (IVS). The corresponding CT attenuation was measured, and the CT attenuation difference between LV and IVS (IVS-LV) and between DAo and IVS (IVS-DAo) was calculated, respectively. One-way analysis of variance (ANOVA) and linear regression were performed to analyze the relationship between these indicators and Hb levels. The receiver operating characteristic (ROC) curve was used to evaluate prediction performance. RESULTS: Both attenuation on LDCT and CDCT showed significant differences between the healthy group and the anemic group (P < 0.05). In the LDCT group, the LV and DAo were more relevant with the hemoglobin (Hb) level (correlation coefficient 0.618 and 0.602) than other indicators, with AUCs of 0.815 (95% CI: 0.763–0.868) and 0.803 (95% CI: 0.747–0.859), respectively. The linear regression formulas for Hb level with the LV and DAo were 19.14 + 0.15 × HU [95% CI: (16.52, 21.75) + (0.12, 0.17) × HU] and 19.46 + 0.16 × HU [95% CI: (16.55, 22.36) + (0.13, 0.18) × HU], respectively. Youden’s index indicated that 37.5 HU and 38.5 HU were the best thresholds to diagnose anemia for LV and DAo, respectively. In the CDCT group, the LV and IVS-LV got obviously higher correlation coefficients (0.813 and 0.812), with AUCs of 0.831 (95% CI: 0.786–0.877) and 0.851 (95% CI: 0.808–0.894), respectively. The optimal thresholds for LV and IVS-LV were 40.5 HU and 9.5 HU, respectively. CONCLUSION: In LDCT examinations, an approximation of Hb level and detecting of anemia can be conducted based on simple attenuation measurements.
format Online
Article
Text
id pubmed-9645455
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-96454552022-11-15 Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort Zhang, Jianing Wu, Minghao Huang, Jinchao Li, Shixia Ye, Zhaoxiang Front Cardiovasc Med Cardiovascular Medicine PURPOSE: To investigate and evaluate the value of thoracic low dose computed tomography (LDCT) scan in the diagnosis of anemia. MATERIALS AND METHODS: 661 patients who received thoracic computed tomography (CT) examination and underwent a peripheral blood examination were retrospectively included. 341 patients underwent conventional dose CT (CDCT), and 320 patients underwent LDCT. Regions of interest (ROI) were placed on the left ventricular cavity (LV), descending aorta (DAo), and interventricular septum (IVS). The corresponding CT attenuation was measured, and the CT attenuation difference between LV and IVS (IVS-LV) and between DAo and IVS (IVS-DAo) was calculated, respectively. One-way analysis of variance (ANOVA) and linear regression were performed to analyze the relationship between these indicators and Hb levels. The receiver operating characteristic (ROC) curve was used to evaluate prediction performance. RESULTS: Both attenuation on LDCT and CDCT showed significant differences between the healthy group and the anemic group (P < 0.05). In the LDCT group, the LV and DAo were more relevant with the hemoglobin (Hb) level (correlation coefficient 0.618 and 0.602) than other indicators, with AUCs of 0.815 (95% CI: 0.763–0.868) and 0.803 (95% CI: 0.747–0.859), respectively. The linear regression formulas for Hb level with the LV and DAo were 19.14 + 0.15 × HU [95% CI: (16.52, 21.75) + (0.12, 0.17) × HU] and 19.46 + 0.16 × HU [95% CI: (16.55, 22.36) + (0.13, 0.18) × HU], respectively. Youden’s index indicated that 37.5 HU and 38.5 HU were the best thresholds to diagnose anemia for LV and DAo, respectively. In the CDCT group, the LV and IVS-LV got obviously higher correlation coefficients (0.813 and 0.812), with AUCs of 0.831 (95% CI: 0.786–0.877) and 0.851 (95% CI: 0.808–0.894), respectively. The optimal thresholds for LV and IVS-LV were 40.5 HU and 9.5 HU, respectively. CONCLUSION: In LDCT examinations, an approximation of Hb level and detecting of anemia can be conducted based on simple attenuation measurements. Frontiers Media S.A. 2022-10-26 /pmc/articles/PMC9645455/ /pubmed/36386355 http://dx.doi.org/10.3389/fcvm.2022.987753 Text en Copyright © 2022 Zhang, Wu, Huang, Li and Ye. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Zhang, Jianing
Wu, Minghao
Huang, Jinchao
Li, Shixia
Ye, Zhaoxiang
Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title_full Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title_fullStr Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title_full_unstemmed Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title_short Comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: A preliminary study in a Chinese screening cohort
title_sort comparison between thoracic low-dose computed tomography and conventional-dose computed tomography in evaluating anemia: a preliminary study in a chinese screening cohort
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9645455/
https://www.ncbi.nlm.nih.gov/pubmed/36386355
http://dx.doi.org/10.3389/fcvm.2022.987753
work_keys_str_mv AT zhangjianing comparisonbetweenthoraciclowdosecomputedtomographyandconventionaldosecomputedtomographyinevaluatinganemiaapreliminarystudyinachinesescreeningcohort
AT wuminghao comparisonbetweenthoraciclowdosecomputedtomographyandconventionaldosecomputedtomographyinevaluatinganemiaapreliminarystudyinachinesescreeningcohort
AT huangjinchao comparisonbetweenthoraciclowdosecomputedtomographyandconventionaldosecomputedtomographyinevaluatinganemiaapreliminarystudyinachinesescreeningcohort
AT lishixia comparisonbetweenthoraciclowdosecomputedtomographyandconventionaldosecomputedtomographyinevaluatinganemiaapreliminarystudyinachinesescreeningcohort
AT yezhaoxiang comparisonbetweenthoraciclowdosecomputedtomographyandconventionaldosecomputedtomographyinevaluatinganemiaapreliminarystudyinachinesescreeningcohort