Cargando…

Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody

[Image: see text] Background: Conventional laboratory tests require plasma separation using centrifugation by skilled personnel in well-equipped lab. Development of a simple, reliable, and cheap point-of-care (POC) test for plasma separation will overcome these limitations. Methods: Plasma separatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Tamimi, Mohammad, Altarawneh, Shahed, Alsallaq, Mariam, Ayoub, Mai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9647767/
https://www.ncbi.nlm.nih.gov/pubmed/36385881
http://dx.doi.org/10.1021/acsomega.2c04908
_version_ 1784827446448619520
author Al-Tamimi, Mohammad
Altarawneh, Shahed
Alsallaq, Mariam
Ayoub, Mai
author_facet Al-Tamimi, Mohammad
Altarawneh, Shahed
Alsallaq, Mariam
Ayoub, Mai
author_sort Al-Tamimi, Mohammad
collection PubMed
description [Image: see text] Background: Conventional laboratory tests require plasma separation using centrifugation by skilled personnel in well-equipped lab. Development of a simple, reliable, and cheap point-of-care (POC) test for plasma separation will overcome these limitations. Methods: Plasma separation was achieved in filter paper using the anti-H agglutinating antibody. Hydrophobic channels were created using a solid ink printer. The reproducibility, efficiency, recovery, and applicability of the assay were validated on a large number of blood samples. Results: A simple, fast, cheap, and direct paper-based assay for plasma separation from whole blood using universal anti-H agglutinating antibody was developed without equipment or pretreatment requirements. The purity of plasma separation using anti-H treated paper was confirmed by microscopy and biuret test for plasma albumin detection. Plasma separation was affected by paper structure, antibody concentration, donor gender, and hematocrit. The efficiency of the assay was 72% and the reproducibility was about 90% with minimal interassay and intra-assay variabilities. The assay successfully separated plasma from 116/119 samples, indicating high sensitivity (97.5%). Furthermore, the assay accurately recovers thyroid stimulating hormone from samples compared to standard methods with 107% recovery rate. Conclusions: Paper-based plasma separation using anti-H agglutinating antibodies would have numerous applications in paper-based POC tests and in resource limited areas.
format Online
Article
Text
id pubmed-9647767
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-96477672022-11-15 Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody Al-Tamimi, Mohammad Altarawneh, Shahed Alsallaq, Mariam Ayoub, Mai ACS Omega [Image: see text] Background: Conventional laboratory tests require plasma separation using centrifugation by skilled personnel in well-equipped lab. Development of a simple, reliable, and cheap point-of-care (POC) test for plasma separation will overcome these limitations. Methods: Plasma separation was achieved in filter paper using the anti-H agglutinating antibody. Hydrophobic channels were created using a solid ink printer. The reproducibility, efficiency, recovery, and applicability of the assay were validated on a large number of blood samples. Results: A simple, fast, cheap, and direct paper-based assay for plasma separation from whole blood using universal anti-H agglutinating antibody was developed without equipment or pretreatment requirements. The purity of plasma separation using anti-H treated paper was confirmed by microscopy and biuret test for plasma albumin detection. Plasma separation was affected by paper structure, antibody concentration, donor gender, and hematocrit. The efficiency of the assay was 72% and the reproducibility was about 90% with minimal interassay and intra-assay variabilities. The assay successfully separated plasma from 116/119 samples, indicating high sensitivity (97.5%). Furthermore, the assay accurately recovers thyroid stimulating hormone from samples compared to standard methods with 107% recovery rate. Conclusions: Paper-based plasma separation using anti-H agglutinating antibodies would have numerous applications in paper-based POC tests and in resource limited areas. American Chemical Society 2022-10-28 /pmc/articles/PMC9647767/ /pubmed/36385881 http://dx.doi.org/10.1021/acsomega.2c04908 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Al-Tamimi, Mohammad
Altarawneh, Shahed
Alsallaq, Mariam
Ayoub, Mai
Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title_full Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title_fullStr Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title_full_unstemmed Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title_short Efficient and Simple Paper-Based Assay for Plasma Separation Using Universal Anti-H Agglutinating Antibody
title_sort efficient and simple paper-based assay for plasma separation using universal anti-h agglutinating antibody
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9647767/
https://www.ncbi.nlm.nih.gov/pubmed/36385881
http://dx.doi.org/10.1021/acsomega.2c04908
work_keys_str_mv AT altamimimohammad efficientandsimplepaperbasedassayforplasmaseparationusinguniversalantihagglutinatingantibody
AT altarawnehshahed efficientandsimplepaperbasedassayforplasmaseparationusinguniversalantihagglutinatingantibody
AT alsallaqmariam efficientandsimplepaperbasedassayforplasmaseparationusinguniversalantihagglutinatingantibody
AT ayoubmai efficientandsimplepaperbasedassayforplasmaseparationusinguniversalantihagglutinatingantibody