Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of...

Descripción completa

Detalles Bibliográficos
Autores principales: Kollar, Sarah E., Udine, Michelle L., Mandell, Jason G., Cross, Russell R., Loke, Yue-Hin, Olivieri, Laura J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9648014/
https://www.ncbi.nlm.nih.gov/pubmed/36352454
http://dx.doi.org/10.1186/s12968-022-00886-w
_version_ 1784827490024292352
author Kollar, Sarah E.
Udine, Michelle L.
Mandell, Jason G.
Cross, Russell R.
Loke, Yue-Hin
Olivieri, Laura J.
author_facet Kollar, Sarah E.
Udine, Michelle L.
Mandell, Jason G.
Cross, Russell R.
Loke, Yue-Hin
Olivieri, Laura J.
author_sort Kollar, Sarah E.
collection PubMed
description BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. METHODS: This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. RESULTS: Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m(2), p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. CONCLUSIONS: Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD.
format Online
Article
Text
id pubmed-9648014
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-96480142022-11-15 Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease Kollar, Sarah E. Udine, Michelle L. Mandell, Jason G. Cross, Russell R. Loke, Yue-Hin Olivieri, Laura J. J Cardiovasc Magn Reson Research BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for time-resolved three-dimensional phase-contrast (4D Flow) analysis of congenital heart disease (CHD). Higher spatial resolution in small infants requires thinner slices, which can degrade the signal. Particularly in infants, the choice of contrast agent (ferumoxytol vs. gadolinium) may influence 4D Flow CMR accuracy. Thus, we investigated the accuracy of 4D Flow CMR measurements compared to gold standard 2D flow phase contrast (PC) measurements in ferumoxytol vs. gadolinium-enhanced CMR of small CHD patients with shunt lesions. METHODS: This was a retrospective study consisting of CMR studies from complex CHD patients less than 20 kg who had ferumoxytol or gadolinium-enhanced 4D Flow and standard two-dimensional phase contrast (2D-PC) flow collected. 4D Flow clinical software (Arterys) was used to measure flow in great vessels, systemic veins, and pulmonary veins. 4D Flow accuracy was defined as percent difference or correlation against conventional measurements (2D-PC) from the same vessels. Subgroup analysis was performed on two-ventricular vs single-ventricular CHD, arterial vs venous flow, as well as low flows (defined as < 1.5 L/min) in 1V CHD. RESULTS: Twenty-one ferumoxytol-enhanced and 23 gadolinium-enhanced CMR studies were included, with no difference in age (2.1 ± 1.6 vs. 2.3 ± 1.9 years, p = 0.70), patient body surface area (0.50 ± 0.2 vs. 0.52 ± 0.2 m(2), p = 0.67), or vessel diameter (11.4 ± 5.2 vs. 12.4 ± 5.6 mm, p = 0.22). Ten CMR studies with single ventricular CHD were included. Overall, ferumoxytol-enhanced 4D flow CMR measurements demonstrated less percent difference to 2D-PC when compared to gadolinium-enhanced 4D Flow CMR studies. In subgroup analyses of arterial vs. venous flows (high velocity vs. low velocity) and low flow in single ventricle CHD, ferumoxytol-enhanced 4D Flow CMR measurements had stronger correlation to 2D-PC CMR. The contrast-to-noise ratio (CNR) in ferumoxytol-enhanced studies was higher than the CNR in gadolinium-enhanced studies. CONCLUSIONS: Ferumoxytol-enhanced 4D Flow CMR has improved accuracy when compared to gadolinium 4D Flow CMR, particularly for infants with small vessels in CHD. BioMed Central 2022-11-10 /pmc/articles/PMC9648014/ /pubmed/36352454 http://dx.doi.org/10.1186/s12968-022-00886-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kollar, Sarah E.
Udine, Michelle L.
Mandell, Jason G.
Cross, Russell R.
Loke, Yue-Hin
Olivieri, Laura J.
Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title_full Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title_fullStr Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title_full_unstemmed Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title_short Impact of ferumoxytol vs gadolinium on 4D flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
title_sort impact of ferumoxytol vs gadolinium on 4d flow cardiovascular magnetic resonance measurements in small children with congenital heart disease
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9648014/
https://www.ncbi.nlm.nih.gov/pubmed/36352454
http://dx.doi.org/10.1186/s12968-022-00886-w
work_keys_str_mv AT kollarsarahe impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease
AT udinemichellel impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease
AT mandelljasong impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease
AT crossrussellr impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease
AT lokeyuehin impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease
AT olivierilauraj impactofferumoxytolvsgadoliniumon4dflowcardiovascularmagneticresonancemeasurementsinsmallchildrenwithcongenitalheartdisease