Cargando…

Micromotion-based balanced drilling technology to increase near cortical strain

OBJECTIVE: A micromotion-based balanced drilling system was designed based on a locking plate (LP) and far cortical locking (FCL) concept to maintain the balance of micromotions of the cortex on both sides of a fracture region. The system was tested by axial compression test. METHODS: The fracture g...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yang, Zou, Qiang, Wang, Zhanchao, Wang, Wei, Shen, Hao, Lu, Hua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9650907/
https://www.ncbi.nlm.nih.gov/pubmed/36368981
http://dx.doi.org/10.1186/s12893-022-01816-4
_version_ 1784828127354028032
author Wang, Yang
Zou, Qiang
Wang, Zhanchao
Wang, Wei
Shen, Hao
Lu, Hua
author_facet Wang, Yang
Zou, Qiang
Wang, Zhanchao
Wang, Wei
Shen, Hao
Lu, Hua
author_sort Wang, Yang
collection PubMed
description OBJECTIVE: A micromotion-based balanced drilling system was designed based on a locking plate (LP) and far cortical locking (FCL) concept to maintain the balance of micromotions of the cortex on both sides of a fracture region. The system was tested by axial compression test. METHODS: The fracture gap was set to 2 cm, and locking screws with a diameter of 5 mm and a locking plate were used to fix it. The diameters of the two sections of the stepping drill were 3.5 mm and 5.0 mm, respectively. One of the matching drilling sleeves was a standard sleeve (eccentricity, 0 mm) and the other was an eccentric sleeve (proximal eccentricity, 1 mm). A model of the fixed locking plate (AO/ASIF 33-A3) for distal femoral fractures with a gap of 2 cm was established based on data from 42 artificial femurs (SAWBONE). According to the shape of the screw holes on the cortex, the fixed fracture models were divided into a control group (standard screw hole group X126, six cases) and an experimental group (elliptical screw hole group N, 36 cases). The experimental group was further divided into six subgroups with six cases in each (N126, N136, N1256, N1356, N12356, N123456), based on the number and distribution of the screws on the proximal fracture segment. The control, N126, and N136 groups were subjected to an axial load of 500 N, and the other groups were subjected to an axial load of 1000 N. The displacements of the kinetic head, far cortex, and near cortex were measured. The integral structural stiffness of the model and the near cortical strain were calculated. The data of each group were analyzed by using a paired t-test. RESULTS: When the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were 0.96%, 2.35%, and 4.62%, respectively, significantly higher than those in the control group (X126) (p < 0.05). For a different distribution of the screws, when the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were significantly higher than those in group N136 (p < 0.05). However, there was no significant difference between the near cortical strains in the two groups with four screws (p > 0.05). For different numbers of screws, the near cortical strains in the three-screw groups were significantly higher than those in the four-screw groups (p < 0.05), and there was no significant difference in near cortical strains among the four-, five-, and six-screw groups (p > 0.05). CONCLUSION: The proposed drill and matching sleeves enabled a conventional locking compression plate to be transformed into an internal fixation system to improve the balanced motion of the near and far cortices. Thus, strain on a fracture site could be controlled by adjusting the diameter of the drill and the eccentricity of the sleeve.
format Online
Article
Text
id pubmed-9650907
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-96509072022-11-15 Micromotion-based balanced drilling technology to increase near cortical strain Wang, Yang Zou, Qiang Wang, Zhanchao Wang, Wei Shen, Hao Lu, Hua BMC Surg Research OBJECTIVE: A micromotion-based balanced drilling system was designed based on a locking plate (LP) and far cortical locking (FCL) concept to maintain the balance of micromotions of the cortex on both sides of a fracture region. The system was tested by axial compression test. METHODS: The fracture gap was set to 2 cm, and locking screws with a diameter of 5 mm and a locking plate were used to fix it. The diameters of the two sections of the stepping drill were 3.5 mm and 5.0 mm, respectively. One of the matching drilling sleeves was a standard sleeve (eccentricity, 0 mm) and the other was an eccentric sleeve (proximal eccentricity, 1 mm). A model of the fixed locking plate (AO/ASIF 33-A3) for distal femoral fractures with a gap of 2 cm was established based on data from 42 artificial femurs (SAWBONE). According to the shape of the screw holes on the cortex, the fixed fracture models were divided into a control group (standard screw hole group X126, six cases) and an experimental group (elliptical screw hole group N, 36 cases). The experimental group was further divided into six subgroups with six cases in each (N126, N136, N1256, N1356, N12356, N123456), based on the number and distribution of the screws on the proximal fracture segment. The control, N126, and N136 groups were subjected to an axial load of 500 N, and the other groups were subjected to an axial load of 1000 N. The displacements of the kinetic head, far cortex, and near cortex were measured. The integral structural stiffness of the model and the near cortical strain were calculated. The data of each group were analyzed by using a paired t-test. RESULTS: When the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were 0.96%, 2.35%, and 4.62%, respectively, significantly higher than those in the control group (X126) (p < 0.05). For a different distribution of the screws, when the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were significantly higher than those in group N136 (p < 0.05). However, there was no significant difference between the near cortical strains in the two groups with four screws (p > 0.05). For different numbers of screws, the near cortical strains in the three-screw groups were significantly higher than those in the four-screw groups (p < 0.05), and there was no significant difference in near cortical strains among the four-, five-, and six-screw groups (p > 0.05). CONCLUSION: The proposed drill and matching sleeves enabled a conventional locking compression plate to be transformed into an internal fixation system to improve the balanced motion of the near and far cortices. Thus, strain on a fracture site could be controlled by adjusting the diameter of the drill and the eccentricity of the sleeve. BioMed Central 2022-11-11 /pmc/articles/PMC9650907/ /pubmed/36368981 http://dx.doi.org/10.1186/s12893-022-01816-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wang, Yang
Zou, Qiang
Wang, Zhanchao
Wang, Wei
Shen, Hao
Lu, Hua
Micromotion-based balanced drilling technology to increase near cortical strain
title Micromotion-based balanced drilling technology to increase near cortical strain
title_full Micromotion-based balanced drilling technology to increase near cortical strain
title_fullStr Micromotion-based balanced drilling technology to increase near cortical strain
title_full_unstemmed Micromotion-based balanced drilling technology to increase near cortical strain
title_short Micromotion-based balanced drilling technology to increase near cortical strain
title_sort micromotion-based balanced drilling technology to increase near cortical strain
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9650907/
https://www.ncbi.nlm.nih.gov/pubmed/36368981
http://dx.doi.org/10.1186/s12893-022-01816-4
work_keys_str_mv AT wangyang micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain
AT zouqiang micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain
AT wangzhanchao micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain
AT wangwei micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain
AT shenhao micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain
AT luhua micromotionbasedbalanceddrillingtechnologytoincreasenearcorticalstrain