Real-life evaluation of a rapid antigen test (DPP SARS-CoV-2 Antigen) for COVID-19 diagnosis of primary healthcare patients, in the context of the Omicron-dominant wave in Brazil
OBJECTIVES: We aimed to investigate the real-life performance of the rapid antigen test in the context of a primary healthcare setting, including symptomatic and asymptomatic individuals that sought diagnosis during an Omicron infection wave. METHODS: We prospectively accessed the performance of the...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9651999/ https://www.ncbi.nlm.nih.gov/pubmed/36375745 http://dx.doi.org/10.1016/j.cmi.2022.11.003 |
Sumario: | OBJECTIVES: We aimed to investigate the real-life performance of the rapid antigen test in the context of a primary healthcare setting, including symptomatic and asymptomatic individuals that sought diagnosis during an Omicron infection wave. METHODS: We prospectively accessed the performance of the DPP SARS-CoV-2 Antigen test in the context of an Omicron-dominant real-life setting. We evaluated 347 unselected individuals (all-comers) from a public testing centre in Brazil, performing the rapid antigen test diagnosis at point-of-care with fresh samples. The combinatory result from two distinct real-time quantitative PCR (RT-qPCR) methods was employed as a reference and 13 samples with discordant PCR results were excluded. RESULTS: The assessment of the rapid test in 67 PCR-positive and 265 negative samples revealed an overall sensitivity of 80.5% (CI 95% = 69.1%–89.2%), specificity of 99.2% (CI 95% = 97.3%–99.1%) and positive/negative predictive values higher than 95%. However, we observed that the sensitivity was dependent on the viral load (sensitivity in Ct < 31 = 93.7%, CI = 82.8%–98.7%; Ct > 31 = 47.4%, CI = 24.4%–71.1%). The positive samples evaluated in the study were Omicron (BA.1/BA.1.1) by whole-genome sequencing (n = 40) and multiplex RT-qPCR (n = 17). CONCLUSIONS: Altogether, the data obtained from a real-life prospective cohort supports that the rapid antigen test sensitivity for Omicron remains high and underscores the reliability of the test for COVID-19 diagnosis in settings with high disease prevalence and limited PCR testing capability. |
---|