Cargando…

Improving safety and communication for healthcare providers caring for SARS-COV-2 patients

BACKGROUND: Decreasing healthcare provider (HCP) exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) virus in emergency departments (EDs) is crucial. Approaches include limiting the HCP presence and ensuring sealed isolation rooms, which can result in communication difficult...

Descripción completa

Detalles Bibliográficos
Autores principales: Taher, Ahmed, Glazer, Peter, Culligan, Chris, Crump, Stephanie, Guirguis, Steven, Jones, Jennifer, Dharamsi, Alia, Chartier, Lucas B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9652974/
https://www.ncbi.nlm.nih.gov/pubmed/36371166
http://dx.doi.org/10.1186/s12245-022-00464-y
Descripción
Sumario:BACKGROUND: Decreasing healthcare provider (HCP) exposure to the severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) virus in emergency departments (EDs) is crucial. Approaches include limiting the HCP presence and ensuring sealed isolation rooms, which can result in communication difficulties. This quality improvement (QI) initiative aimed to decrease by 50% duration of isolation room door opening and increasing HCP-perceived communication clarity by one point on a five-point Likert scale. METHODS: This was a prospective, multi-stage project with three Plan-Do-Study-Act (PDSA) cycles between May and July 2020: (1) an educational intervention, (2) the introduction of a novel transceiver communication device, and (3) utilizing a clinical champion. Statistical Process Control XbarR charts were used to assess for special cause variation, and two-tailed Mann-Whitney U tests were used for statistical significance between Likert survey means. Qualitative responses underwent thematic analysis. RESULTS: Observation of 174 patient encounters was completed over 33 days, with 95 meeting the inclusion criteria. Door opening decreased from baseline (n=40; mean 72.97%) to PDSA 3 (n=21; mean 1.58%; p<0.0001). HCP-perceived communication clarity improved from baseline (n=36; mean 3.36) to PDSA-3 (n=49; mean 4.21; p<0.001). Survey themes included positive effects on communication and workflow, with some challenges on the integration of the new device into the clinical workflow. HCP-perceived errors, workarounds, and workflow pauses showed significant improvements. CONCLUSION: This QI initiative with a novel transceiver showed significant decreases in isolation room door opening and increases in communication clarity. Future work will expand to operating rooms and intensive care units. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12245-022-00464-y.