Defect Detection of Pipeline Inner Surface Based on Coaxial Digital Image Correlation with Hypercentric Lens
A coaxial dual-camera digital image correlation system using a hypercentric lens was proposed to determine the defect position in the inner wall of a pipeline under loads. Compared with the traditional dual-camera system, this system ensures that both cameras can capture a 360-degree panoramic image...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653717/ https://www.ncbi.nlm.nih.gov/pubmed/36363133 http://dx.doi.org/10.3390/ma15217543 |
Sumario: | A coaxial dual-camera digital image correlation system using a hypercentric lens was proposed to determine the defect position in the inner wall of a pipeline under loads. Compared with the traditional dual-camera system, this system ensures that both cameras can capture a 360-degree panoramic image in the same position. Herein, the imaging principle of the system was introduced in detail. In addition, the effectiveness and accuracy of the proposed method were verified through verification and application experiments. |
---|