Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653926/ https://www.ncbi.nlm.nih.gov/pubmed/36366165 http://dx.doi.org/10.3390/s22218469 |
_version_ | 1784828801922891776 |
---|---|
author | Sun, Yehan Pan, Jun Jiang, Lijun Hao, Libo Cao, Yu Wang, Helin |
author_facet | Sun, Yehan Pan, Jun Jiang, Lijun Hao, Libo Cao, Yu Wang, Helin |
author_sort | Sun, Yehan |
collection | PubMed |
description | The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using the correlation between the information of emission energy and reflected energy of the high-temperature target. Based on the principle of radiative transmission and energy conservation, the relationship between the emissivity and bidirectional reflectance factor (BRF) was used to perform the retrieval of emissivity and temperature. An experimental device was designed, and graphite and rock were considered to verify the feasibility of the experimental scheme. The error of emissivity and temperature of both targets were, respectively, less than 5% and 0.5%, due to the Lambertian assumption, and the systematic errors had negligible impact on the retrieval. This verifies that the experimental observation method and scheme is reasonable. |
format | Online Article Text |
id | pubmed-9653926 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96539262022-11-15 Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR Sun, Yehan Pan, Jun Jiang, Lijun Hao, Libo Cao, Yu Wang, Helin Sensors (Basel) Article The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using the correlation between the information of emission energy and reflected energy of the high-temperature target. Based on the principle of radiative transmission and energy conservation, the relationship between the emissivity and bidirectional reflectance factor (BRF) was used to perform the retrieval of emissivity and temperature. An experimental device was designed, and graphite and rock were considered to verify the feasibility of the experimental scheme. The error of emissivity and temperature of both targets were, respectively, less than 5% and 0.5%, due to the Lambertian assumption, and the systematic errors had negligible impact on the retrieval. This verifies that the experimental observation method and scheme is reasonable. MDPI 2022-11-03 /pmc/articles/PMC9653926/ /pubmed/36366165 http://dx.doi.org/10.3390/s22218469 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sun, Yehan Pan, Jun Jiang, Lijun Hao, Libo Cao, Yu Wang, Helin Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title | Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title_full | Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title_fullStr | Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title_full_unstemmed | Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title_short | Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR |
title_sort | multi-irradiance: a method for simultaneous measurement of the temperature and spectral emissivity of high-temperature targets in swir |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653926/ https://www.ncbi.nlm.nih.gov/pubmed/36366165 http://dx.doi.org/10.3390/s22218469 |
work_keys_str_mv | AT sunyehan multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir AT panjun multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir AT jianglijun multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir AT haolibo multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir AT caoyu multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir AT wanghelin multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir |