Cargando…

Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR

The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Yehan, Pan, Jun, Jiang, Lijun, Hao, Libo, Cao, Yu, Wang, Helin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653926/
https://www.ncbi.nlm.nih.gov/pubmed/36366165
http://dx.doi.org/10.3390/s22218469
_version_ 1784828801922891776
author Sun, Yehan
Pan, Jun
Jiang, Lijun
Hao, Libo
Cao, Yu
Wang, Helin
author_facet Sun, Yehan
Pan, Jun
Jiang, Lijun
Hao, Libo
Cao, Yu
Wang, Helin
author_sort Sun, Yehan
collection PubMed
description The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using the correlation between the information of emission energy and reflected energy of the high-temperature target. Based on the principle of radiative transmission and energy conservation, the relationship between the emissivity and bidirectional reflectance factor (BRF) was used to perform the retrieval of emissivity and temperature. An experimental device was designed, and graphite and rock were considered to verify the feasibility of the experimental scheme. The error of emissivity and temperature of both targets were, respectively, less than 5% and 0.5%, due to the Lambertian assumption, and the systematic errors had negligible impact on the retrieval. This verifies that the experimental observation method and scheme is reasonable.
format Online
Article
Text
id pubmed-9653926
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96539262022-11-15 Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR Sun, Yehan Pan, Jun Jiang, Lijun Hao, Libo Cao, Yu Wang, Helin Sensors (Basel) Article The currently used energy methods in spectral emissivity measurement are susceptible to the difference in temperature between the target and the reference blackbody. It is also limited by the state of the observation target and observation. This paper introduces the irradiance condition, while using the correlation between the information of emission energy and reflected energy of the high-temperature target. Based on the principle of radiative transmission and energy conservation, the relationship between the emissivity and bidirectional reflectance factor (BRF) was used to perform the retrieval of emissivity and temperature. An experimental device was designed, and graphite and rock were considered to verify the feasibility of the experimental scheme. The error of emissivity and temperature of both targets were, respectively, less than 5% and 0.5%, due to the Lambertian assumption, and the systematic errors had negligible impact on the retrieval. This verifies that the experimental observation method and scheme is reasonable. MDPI 2022-11-03 /pmc/articles/PMC9653926/ /pubmed/36366165 http://dx.doi.org/10.3390/s22218469 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sun, Yehan
Pan, Jun
Jiang, Lijun
Hao, Libo
Cao, Yu
Wang, Helin
Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title_full Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title_fullStr Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title_full_unstemmed Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title_short Multi-Irradiance: A Method for Simultaneous Measurement of the Temperature and Spectral Emissivity of High-Temperature Targets in SWIR
title_sort multi-irradiance: a method for simultaneous measurement of the temperature and spectral emissivity of high-temperature targets in swir
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9653926/
https://www.ncbi.nlm.nih.gov/pubmed/36366165
http://dx.doi.org/10.3390/s22218469
work_keys_str_mv AT sunyehan multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir
AT panjun multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir
AT jianglijun multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir
AT haolibo multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir
AT caoyu multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir
AT wanghelin multiirradianceamethodforsimultaneousmeasurementofthetemperatureandspectralemissivityofhightemperaturetargetsinswir