Cargando…
Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function
Background: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles. Methods: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9654584/ https://www.ncbi.nlm.nih.gov/pubmed/36362471 http://dx.doi.org/10.3390/jcm11216243 |
_version_ | 1784828968950562816 |
---|---|
author | Lops, Diego Romeo, Eugenio Calza, Stefano Palazzolo, Antonino Viviani, Lorenzo Salgarello, Stefano Buffoli, Barbara Mensi, Magda |
author_facet | Lops, Diego Romeo, Eugenio Calza, Stefano Palazzolo, Antonino Viviani, Lorenzo Salgarello, Stefano Buffoli, Barbara Mensi, Magda |
author_sort | Lops, Diego |
collection | PubMed |
description | Background: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles. Methods: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle (EA) measured at 3 years of follow-up visits (t1) were calculated for two different groups: Group 1 (153 implants) for restorations with angle between implant axis and prosthetic emergence angle from ≥30°, and Group 2 (67 implants) for those with angle ≤30°, respectively. Image J software was used for the measurements. Moreover, peri-implant soft tissue parameters such as pocket probing depth (PPD), plaque index (PI) and gingival index (GI) were assessed, respectively. Results: A total of 57 patients were included in the analysis and a total of 220 implants were examined. Mean (±SD) EA in Groups 1 and 2 was 46.4 ± 12.2 and 24.5 ± 4.7 degrees, respectively. After 3 years of follow-up, a PPD difference of 0.062 mm (CI(95%) −0.041 mm; 0.164 mm) was calculated between the two groups and was not statistically significant (p = 0.238). Similar results were found for PI (OR = 0.78, CI(95%) 0.31; 1.98, p = 0.599). Furthermore, GI scores of 2 and 3 were found for nine implants (5.9%) in Group 1, and for five implants in Group 2 (7.5%). A non-significant difference (p = 0.76) was found. Conclusions: Peri-implant soft-tissue health does not seem to be influenced by EA itself, when a proper emergence profile is provided for implant-supported reconstructions in anterior areas. |
format | Online Article Text |
id | pubmed-9654584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96545842022-11-15 Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function Lops, Diego Romeo, Eugenio Calza, Stefano Palazzolo, Antonino Viviani, Lorenzo Salgarello, Stefano Buffoli, Barbara Mensi, Magda J Clin Med Article Background: The aim of the present retrospective study was to assess peri-implant soft tissue health for implants restored with different prosthetic emergence profile angles. Methods: Patients were treated with implants supporting fixed dentures and were followed for 3 years. Buccal emergence angle (EA) measured at 3 years of follow-up visits (t1) were calculated for two different groups: Group 1 (153 implants) for restorations with angle between implant axis and prosthetic emergence angle from ≥30°, and Group 2 (67 implants) for those with angle ≤30°, respectively. Image J software was used for the measurements. Moreover, peri-implant soft tissue parameters such as pocket probing depth (PPD), plaque index (PI) and gingival index (GI) were assessed, respectively. Results: A total of 57 patients were included in the analysis and a total of 220 implants were examined. Mean (±SD) EA in Groups 1 and 2 was 46.4 ± 12.2 and 24.5 ± 4.7 degrees, respectively. After 3 years of follow-up, a PPD difference of 0.062 mm (CI(95%) −0.041 mm; 0.164 mm) was calculated between the two groups and was not statistically significant (p = 0.238). Similar results were found for PI (OR = 0.78, CI(95%) 0.31; 1.98, p = 0.599). Furthermore, GI scores of 2 and 3 were found for nine implants (5.9%) in Group 1, and for five implants in Group 2 (7.5%). A non-significant difference (p = 0.76) was found. Conclusions: Peri-implant soft-tissue health does not seem to be influenced by EA itself, when a proper emergence profile is provided for implant-supported reconstructions in anterior areas. MDPI 2022-10-23 /pmc/articles/PMC9654584/ /pubmed/36362471 http://dx.doi.org/10.3390/jcm11216243 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lops, Diego Romeo, Eugenio Calza, Stefano Palazzolo, Antonino Viviani, Lorenzo Salgarello, Stefano Buffoli, Barbara Mensi, Magda Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title | Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title_full | Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title_fullStr | Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title_full_unstemmed | Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title_short | Association between Peri-Implant Soft Tissue Health and Different Prosthetic Emergence Angles in Esthetic Areas: Digital Evaluation after 3 Years’ Function |
title_sort | association between peri-implant soft tissue health and different prosthetic emergence angles in esthetic areas: digital evaluation after 3 years’ function |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9654584/ https://www.ncbi.nlm.nih.gov/pubmed/36362471 http://dx.doi.org/10.3390/jcm11216243 |
work_keys_str_mv | AT lopsdiego associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT romeoeugenio associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT calzastefano associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT palazzoloantonino associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT vivianilorenzo associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT salgarellostefano associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT buffolibarbara associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction AT mensimagda associationbetweenperiimplantsofttissuehealthanddifferentprostheticemergenceanglesinestheticareasdigitalevaluationafter3yearsfunction |