Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization
Background: Dynamic needle-tip positioning (DNTP) was shown to improve arterial cannulation efficiency with fewer complications than conventional palpation and ultrasound methods by some studies. However, this is still controversial, and we performed this meta-analysis to comprehensively assess its...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655328/ https://www.ncbi.nlm.nih.gov/pubmed/36362767 http://dx.doi.org/10.3390/jcm11216539 |
_version_ | 1784829158593921024 |
---|---|
author | Wu, Guannan Chen, Chen Gu, Xiaoling Yao, Yanwen Yuan, Dongmei Lv, Jiawen Zhao, Beilei Wang, Qin |
author_facet | Wu, Guannan Chen, Chen Gu, Xiaoling Yao, Yanwen Yuan, Dongmei Lv, Jiawen Zhao, Beilei Wang, Qin |
author_sort | Wu, Guannan |
collection | PubMed |
description | Background: Dynamic needle-tip positioning (DNTP) was shown to improve arterial cannulation efficiency with fewer complications than conventional palpation and ultrasound methods by some studies. However, this is still controversial, and we performed this meta-analysis to comprehensively assess its value in arterial cannulation. Methods: A literature search of randomized controlled trials was conducted, and 11 studies were finally included. Efficiency outcomes (first-attempt success, overall success, and total cannulation time) and complications (hematoma, thrombosis, posterior wall puncture, and vasospasm) were separately analyzed. Subgroup analyses in different populations under cannulation were also performed. Results: DNTP was associated with increased first-attempt success (pooled RR = 1.792, p < 0.001), overall success (pooled RR = 1.368, p = 0.001), and decreased cannulation time (pooled SMD = −1.758, p = 0.001) than palpation. DNTP gained even more advantage in small children and infants. No significant difference in these outcomes between DNTP and conventional ultrasound method was detected. Fewer hematoma occurred in DNTP than palpation (pooled RR = 0.265, p < 0.001) or traditional ultrasound (pooled RR = 0.348, p < 0.001). DNPT was also associated with fewer posterior wall punctures (pooled RR = 0.495, p = 0.001) and vasospasm (pooled RR = 0.267, p = 0.007) than traditional ultrasound. Conclusions: DNTP was a better choice in artery cannulation than conventional palpation and ultrasound method, especially in small children and infants. |
format | Online Article Text |
id | pubmed-9655328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96553282022-11-15 Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization Wu, Guannan Chen, Chen Gu, Xiaoling Yao, Yanwen Yuan, Dongmei Lv, Jiawen Zhao, Beilei Wang, Qin J Clin Med Review Background: Dynamic needle-tip positioning (DNTP) was shown to improve arterial cannulation efficiency with fewer complications than conventional palpation and ultrasound methods by some studies. However, this is still controversial, and we performed this meta-analysis to comprehensively assess its value in arterial cannulation. Methods: A literature search of randomized controlled trials was conducted, and 11 studies were finally included. Efficiency outcomes (first-attempt success, overall success, and total cannulation time) and complications (hematoma, thrombosis, posterior wall puncture, and vasospasm) were separately analyzed. Subgroup analyses in different populations under cannulation were also performed. Results: DNTP was associated with increased first-attempt success (pooled RR = 1.792, p < 0.001), overall success (pooled RR = 1.368, p = 0.001), and decreased cannulation time (pooled SMD = −1.758, p = 0.001) than palpation. DNTP gained even more advantage in small children and infants. No significant difference in these outcomes between DNTP and conventional ultrasound method was detected. Fewer hematoma occurred in DNTP than palpation (pooled RR = 0.265, p < 0.001) or traditional ultrasound (pooled RR = 0.348, p < 0.001). DNPT was also associated with fewer posterior wall punctures (pooled RR = 0.495, p = 0.001) and vasospasm (pooled RR = 0.267, p = 0.007) than traditional ultrasound. Conclusions: DNTP was a better choice in artery cannulation than conventional palpation and ultrasound method, especially in small children and infants. MDPI 2022-11-03 /pmc/articles/PMC9655328/ /pubmed/36362767 http://dx.doi.org/10.3390/jcm11216539 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Wu, Guannan Chen, Chen Gu, Xiaoling Yao, Yanwen Yuan, Dongmei Lv, Jiawen Zhao, Beilei Wang, Qin Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title | Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title_full | Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title_fullStr | Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title_full_unstemmed | Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title_short | Ultrasound-Guided Dynamic Needle-Tip Positioning Method Is Superior to Conventional Palpation and Ultrasound Method in Arterial Catheterization |
title_sort | ultrasound-guided dynamic needle-tip positioning method is superior to conventional palpation and ultrasound method in arterial catheterization |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655328/ https://www.ncbi.nlm.nih.gov/pubmed/36362767 http://dx.doi.org/10.3390/jcm11216539 |
work_keys_str_mv | AT wuguannan ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT chenchen ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT guxiaoling ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT yaoyanwen ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT yuandongmei ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT lvjiawen ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT zhaobeilei ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization AT wangqin ultrasoundguideddynamicneedletippositioningmethodissuperiortoconventionalpalpationandultrasoundmethodinarterialcatheterization |