Cargando…

Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application

An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Dang, Minh Phung, Le, Hieu Giang, Phan, Thu Thi Dang, Chau, Ngoc Le, Dao, Thanh-Phong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655923/
https://www.ncbi.nlm.nih.gov/pubmed/36365907
http://dx.doi.org/10.3390/s22218204
_version_ 1784829305708085248
author Dang, Minh Phung
Le, Hieu Giang
Phan, Thu Thi Dang
Chau, Ngoc Le
Dao, Thanh-Phong
author_facet Dang, Minh Phung
Le, Hieu Giang
Phan, Thu Thi Dang
Chau, Ngoc Le
Dao, Thanh-Phong
author_sort Dang, Minh Phung
collection PubMed
description An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The proposed micropositioner is a planar mechanism whose advantage is a generation of three motions with only two actuators. In the design strategy, the proposed micropositioner is designed by a combination of a symmetrical four-lever displacement amplifier, a symmetrical parallel guiding mechanism, and a symmetrical parallel redirection mechanism. The Z-shaped hinges are used to gain motion in the Z-axis displacement. Four flexure right-circular hinges are combined with two rigid joints and two flexure leaf hinges to permit two large X-and-Y displacements. The symmetrical four-lever displacement amplifier is designed to increase the micropositioner’s travel. The displacement sensor is built by embedding the strain gauges on the hinges of the micropositioner, which is developed to measure the travel of the micropositioner. The behaviors and performances of the micropositioner are modeled by using the Taguchi-based response surface methodology. Additionally, the geometrical factors of the XYZ micropositioner are optimized by teaching–learning-based optimization. The optimized design parameters are defined with an A of 0.9 mm, a B of 0.8 mm, a C of 0.57 mm, and a D of 0.7 mm. The safety factor gains 1.85, while the displacement achieves 515.7278 µm. The developed micropositioner is a potential option for biomedical sample testing in a nanoindentation system.
format Online
Article
Text
id pubmed-9655923
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96559232022-11-15 Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application Dang, Minh Phung Le, Hieu Giang Phan, Thu Thi Dang Chau, Ngoc Le Dao, Thanh-Phong Sensors (Basel) Article An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The proposed micropositioner is a planar mechanism whose advantage is a generation of three motions with only two actuators. In the design strategy, the proposed micropositioner is designed by a combination of a symmetrical four-lever displacement amplifier, a symmetrical parallel guiding mechanism, and a symmetrical parallel redirection mechanism. The Z-shaped hinges are used to gain motion in the Z-axis displacement. Four flexure right-circular hinges are combined with two rigid joints and two flexure leaf hinges to permit two large X-and-Y displacements. The symmetrical four-lever displacement amplifier is designed to increase the micropositioner’s travel. The displacement sensor is built by embedding the strain gauges on the hinges of the micropositioner, which is developed to measure the travel of the micropositioner. The behaviors and performances of the micropositioner are modeled by using the Taguchi-based response surface methodology. Additionally, the geometrical factors of the XYZ micropositioner are optimized by teaching–learning-based optimization. The optimized design parameters are defined with an A of 0.9 mm, a B of 0.8 mm, a C of 0.57 mm, and a D of 0.7 mm. The safety factor gains 1.85, while the displacement achieves 515.7278 µm. The developed micropositioner is a potential option for biomedical sample testing in a nanoindentation system. MDPI 2022-10-26 /pmc/articles/PMC9655923/ /pubmed/36365907 http://dx.doi.org/10.3390/s22218204 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dang, Minh Phung
Le, Hieu Giang
Phan, Thu Thi Dang
Chau, Ngoc Le
Dao, Thanh-Phong
Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title_full Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title_fullStr Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title_full_unstemmed Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title_short Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
title_sort design and optimization for a new xyz micropositioner with embedded displacement sensor for biomaterial sample probing application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655923/
https://www.ncbi.nlm.nih.gov/pubmed/36365907
http://dx.doi.org/10.3390/s22218204
work_keys_str_mv AT dangminhphung designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication
AT lehieugiang designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication
AT phanthuthidang designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication
AT chaungocle designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication
AT daothanhphong designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication