Cargando…
Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application
An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655923/ https://www.ncbi.nlm.nih.gov/pubmed/36365907 http://dx.doi.org/10.3390/s22218204 |
_version_ | 1784829305708085248 |
---|---|
author | Dang, Minh Phung Le, Hieu Giang Phan, Thu Thi Dang Chau, Ngoc Le Dao, Thanh-Phong |
author_facet | Dang, Minh Phung Le, Hieu Giang Phan, Thu Thi Dang Chau, Ngoc Le Dao, Thanh-Phong |
author_sort | Dang, Minh Phung |
collection | PubMed |
description | An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The proposed micropositioner is a planar mechanism whose advantage is a generation of three motions with only two actuators. In the design strategy, the proposed micropositioner is designed by a combination of a symmetrical four-lever displacement amplifier, a symmetrical parallel guiding mechanism, and a symmetrical parallel redirection mechanism. The Z-shaped hinges are used to gain motion in the Z-axis displacement. Four flexure right-circular hinges are combined with two rigid joints and two flexure leaf hinges to permit two large X-and-Y displacements. The symmetrical four-lever displacement amplifier is designed to increase the micropositioner’s travel. The displacement sensor is built by embedding the strain gauges on the hinges of the micropositioner, which is developed to measure the travel of the micropositioner. The behaviors and performances of the micropositioner are modeled by using the Taguchi-based response surface methodology. Additionally, the geometrical factors of the XYZ micropositioner are optimized by teaching–learning-based optimization. The optimized design parameters are defined with an A of 0.9 mm, a B of 0.8 mm, a C of 0.57 mm, and a D of 0.7 mm. The safety factor gains 1.85, while the displacement achieves 515.7278 µm. The developed micropositioner is a potential option for biomedical sample testing in a nanoindentation system. |
format | Online Article Text |
id | pubmed-9655923 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96559232022-11-15 Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application Dang, Minh Phung Le, Hieu Giang Phan, Thu Thi Dang Chau, Ngoc Le Dao, Thanh-Phong Sensors (Basel) Article An XYZ compliant micropositioner has been widely mentioned in precision engineering, but the displacements in the X, Y, and Z directions are often not the same. In this study, a design and optimization for a new XYZ micropositioner are developed to obtain three same displacements in three axes. The proposed micropositioner is a planar mechanism whose advantage is a generation of three motions with only two actuators. In the design strategy, the proposed micropositioner is designed by a combination of a symmetrical four-lever displacement amplifier, a symmetrical parallel guiding mechanism, and a symmetrical parallel redirection mechanism. The Z-shaped hinges are used to gain motion in the Z-axis displacement. Four flexure right-circular hinges are combined with two rigid joints and two flexure leaf hinges to permit two large X-and-Y displacements. The symmetrical four-lever displacement amplifier is designed to increase the micropositioner’s travel. The displacement sensor is built by embedding the strain gauges on the hinges of the micropositioner, which is developed to measure the travel of the micropositioner. The behaviors and performances of the micropositioner are modeled by using the Taguchi-based response surface methodology. Additionally, the geometrical factors of the XYZ micropositioner are optimized by teaching–learning-based optimization. The optimized design parameters are defined with an A of 0.9 mm, a B of 0.8 mm, a C of 0.57 mm, and a D of 0.7 mm. The safety factor gains 1.85, while the displacement achieves 515.7278 µm. The developed micropositioner is a potential option for biomedical sample testing in a nanoindentation system. MDPI 2022-10-26 /pmc/articles/PMC9655923/ /pubmed/36365907 http://dx.doi.org/10.3390/s22218204 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dang, Minh Phung Le, Hieu Giang Phan, Thu Thi Dang Chau, Ngoc Le Dao, Thanh-Phong Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title | Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title_full | Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title_fullStr | Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title_full_unstemmed | Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title_short | Design and Optimization for a New XYZ Micropositioner with Embedded Displacement Sensor for Biomaterial Sample Probing Application |
title_sort | design and optimization for a new xyz micropositioner with embedded displacement sensor for biomaterial sample probing application |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655923/ https://www.ncbi.nlm.nih.gov/pubmed/36365907 http://dx.doi.org/10.3390/s22218204 |
work_keys_str_mv | AT dangminhphung designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication AT lehieugiang designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication AT phanthuthidang designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication AT chaungocle designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication AT daothanhphong designandoptimizationforanewxyzmicropositionerwithembeddeddisplacementsensorforbiomaterialsampleprobingapplication |