Cargando…

Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor

The global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused a threat to public health and a worldwide crisis. This raised the need for quick, effective, and sensitive detection tools to prevent the rapid transmission rate of the infection. Therefore, this study...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurmangali, Assem, Dukenbayev, Kanat, Kanayeva, Damira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656073/
https://www.ncbi.nlm.nih.gov/pubmed/36361926
http://dx.doi.org/10.3390/ijms232113138
_version_ 1784829343002787840
author Kurmangali, Assem
Dukenbayev, Kanat
Kanayeva, Damira
author_facet Kurmangali, Assem
Dukenbayev, Kanat
Kanayeva, Damira
author_sort Kurmangali, Assem
collection PubMed
description The global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused a threat to public health and a worldwide crisis. This raised the need for quick, effective, and sensitive detection tools to prevent the rapid transmission rate of the infection. Therefore, this study aimed to develop an electrochemical impedance spectroscopy (EIS)-based aptasensor employing an interdigitated gold electrode (IDE) to detect SARS-CoV-2 Spike (S) glycoprotein and viral particles. This allowed us to sensitively detect SARS-CoV-2 S glycoprotein with a limit of detection (LOD) of 0.4 pg/mL in a buffer solution and to obtain a linear increase for concentrations between 0.2 to 0.8 pg/mL with high specificity. The proposed aptasensor also showed a good sensitivity towards the heat-inactivated SARS-CoV-2 variants in a buffer solution, where the Delta, Wuhan, and Alpha variants were captured at a viral titer of 6.45 ± 0.16 × 10(3) TCID(50)/mL, 6.20 × 10(4) TCID(50)/mL, and 5.32 ± 0.13 × 10(2) TCID(50)/mL, respectively. Furthermore, the detection of SARS-CoV-2 performed in a spiked human nasal fluid provided an LOD of 6.45 ± 0.16 × 10(3) TCID(50)/mL for the Delta variant in a 50 µL sample and a detection time of less than 25 min. Atomic force microscopy images complemented the EIS results in this study, revealing that the surface roughness of the IDE after each modification step increased, which indicates that the target was successfully captured. This label-free EIS-based aptasensor has promising potential for the rapid detection of SARS-CoV-2 in complex clinical samples.
format Online
Article
Text
id pubmed-9656073
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96560732022-11-15 Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor Kurmangali, Assem Dukenbayev, Kanat Kanayeva, Damira Int J Mol Sci Article The global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused a threat to public health and a worldwide crisis. This raised the need for quick, effective, and sensitive detection tools to prevent the rapid transmission rate of the infection. Therefore, this study aimed to develop an electrochemical impedance spectroscopy (EIS)-based aptasensor employing an interdigitated gold electrode (IDE) to detect SARS-CoV-2 Spike (S) glycoprotein and viral particles. This allowed us to sensitively detect SARS-CoV-2 S glycoprotein with a limit of detection (LOD) of 0.4 pg/mL in a buffer solution and to obtain a linear increase for concentrations between 0.2 to 0.8 pg/mL with high specificity. The proposed aptasensor also showed a good sensitivity towards the heat-inactivated SARS-CoV-2 variants in a buffer solution, where the Delta, Wuhan, and Alpha variants were captured at a viral titer of 6.45 ± 0.16 × 10(3) TCID(50)/mL, 6.20 × 10(4) TCID(50)/mL, and 5.32 ± 0.13 × 10(2) TCID(50)/mL, respectively. Furthermore, the detection of SARS-CoV-2 performed in a spiked human nasal fluid provided an LOD of 6.45 ± 0.16 × 10(3) TCID(50)/mL for the Delta variant in a 50 µL sample and a detection time of less than 25 min. Atomic force microscopy images complemented the EIS results in this study, revealing that the surface roughness of the IDE after each modification step increased, which indicates that the target was successfully captured. This label-free EIS-based aptasensor has promising potential for the rapid detection of SARS-CoV-2 in complex clinical samples. MDPI 2022-10-28 /pmc/articles/PMC9656073/ /pubmed/36361926 http://dx.doi.org/10.3390/ijms232113138 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kurmangali, Assem
Dukenbayev, Kanat
Kanayeva, Damira
Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title_full Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title_fullStr Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title_full_unstemmed Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title_short Sensitive Detection of SARS-CoV-2 Variants Using an Electrochemical Impedance Spectroscopy Based Aptasensor
title_sort sensitive detection of sars-cov-2 variants using an electrochemical impedance spectroscopy based aptasensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656073/
https://www.ncbi.nlm.nih.gov/pubmed/36361926
http://dx.doi.org/10.3390/ijms232113138
work_keys_str_mv AT kurmangaliassem sensitivedetectionofsarscov2variantsusinganelectrochemicalimpedancespectroscopybasedaptasensor
AT dukenbayevkanat sensitivedetectionofsarscov2variantsusinganelectrochemicalimpedancespectroscopybasedaptasensor
AT kanayevadamira sensitivedetectionofsarscov2variantsusinganelectrochemicalimpedancespectroscopybasedaptasensor