Cargando…

A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites

This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h...

Descripción completa

Detalles Bibliográficos
Autores principales: Hampe, Tristan, Liersch, Julia, Wiechens, Bernhard, Wassmann, Torsten, Schubert, Andrea, Alhussein, Mohammad, Bürgers, Ralf, Krohn, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656414/
https://www.ncbi.nlm.nih.gov/pubmed/36365574
http://dx.doi.org/10.3390/polym14214580
_version_ 1784829428390428672
author Hampe, Tristan
Liersch, Julia
Wiechens, Bernhard
Wassmann, Torsten
Schubert, Andrea
Alhussein, Mohammad
Bürgers, Ralf
Krohn, Sebastian
author_facet Hampe, Tristan
Liersch, Julia
Wiechens, Bernhard
Wassmann, Torsten
Schubert, Andrea
Alhussein, Mohammad
Bürgers, Ralf
Krohn, Sebastian
author_sort Hampe, Tristan
collection PubMed
description This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h in an incubation shaker at 37 °C and 112 rpm. Extraction was performed following ISO 10993-12 and monomers were detected and quantified by HPLC-MS/MS. In all the samples, urethane dimethacrylate (UDMA) and bisphenol A (BPA) were quantifiable. Compared to water blanks, BPA levels were only elevated in the eluates from conventional composites. In all other samples, concentrations were in the range of extraneous BPA and were therefore clinically irrelevant. Low concentrations of Bisphenol A-glycidyl methacrylate (BisGMA) were found in one BPA-free composite and in both conventional materials. Statistical analyses showed that BPA-free materials released significantly less BisGMA and no BPA, while UDMA elution was comparable to elution from conventional materials. All measured concentrations were below reported effective cytotoxic concentrations. Considering these results, the substitution of BPA-derivatives with UDMA might be beneficial since BPA-associated adverse effects are ruled out. Further studies should be enrolled to test the biocompatibility of UDMA on cells of the oral environment.
format Online
Article
Text
id pubmed-9656414
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96564142022-11-15 A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites Hampe, Tristan Liersch, Julia Wiechens, Bernhard Wassmann, Torsten Schubert, Andrea Alhussein, Mohammad Bürgers, Ralf Krohn, Sebastian Polymers (Basel) Article This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h in an incubation shaker at 37 °C and 112 rpm. Extraction was performed following ISO 10993-12 and monomers were detected and quantified by HPLC-MS/MS. In all the samples, urethane dimethacrylate (UDMA) and bisphenol A (BPA) were quantifiable. Compared to water blanks, BPA levels were only elevated in the eluates from conventional composites. In all other samples, concentrations were in the range of extraneous BPA and were therefore clinically irrelevant. Low concentrations of Bisphenol A-glycidyl methacrylate (BisGMA) were found in one BPA-free composite and in both conventional materials. Statistical analyses showed that BPA-free materials released significantly less BisGMA and no BPA, while UDMA elution was comparable to elution from conventional materials. All measured concentrations were below reported effective cytotoxic concentrations. Considering these results, the substitution of BPA-derivatives with UDMA might be beneficial since BPA-associated adverse effects are ruled out. Further studies should be enrolled to test the biocompatibility of UDMA on cells of the oral environment. MDPI 2022-10-28 /pmc/articles/PMC9656414/ /pubmed/36365574 http://dx.doi.org/10.3390/polym14214580 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hampe, Tristan
Liersch, Julia
Wiechens, Bernhard
Wassmann, Torsten
Schubert, Andrea
Alhussein, Mohammad
Bürgers, Ralf
Krohn, Sebastian
A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title_full A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title_fullStr A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title_full_unstemmed A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title_short A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
title_sort pilot study on monomer and bisphenol a (bpa) release from udma-based and conventional indirect veneering composites
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656414/
https://www.ncbi.nlm.nih.gov/pubmed/36365574
http://dx.doi.org/10.3390/polym14214580
work_keys_str_mv AT hampetristan apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT lierschjulia apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT wiechensbernhard apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT wassmanntorsten apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT schubertandrea apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT alhusseinmohammad apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT burgersralf apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT krohnsebastian apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT hampetristan pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT lierschjulia pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT wiechensbernhard pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT wassmanntorsten pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT schubertandrea pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT alhusseinmohammad pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT burgersralf pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites
AT krohnsebastian pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites