Cargando…
A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites
This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656414/ https://www.ncbi.nlm.nih.gov/pubmed/36365574 http://dx.doi.org/10.3390/polym14214580 |
_version_ | 1784829428390428672 |
---|---|
author | Hampe, Tristan Liersch, Julia Wiechens, Bernhard Wassmann, Torsten Schubert, Andrea Alhussein, Mohammad Bürgers, Ralf Krohn, Sebastian |
author_facet | Hampe, Tristan Liersch, Julia Wiechens, Bernhard Wassmann, Torsten Schubert, Andrea Alhussein, Mohammad Bürgers, Ralf Krohn, Sebastian |
author_sort | Hampe, Tristan |
collection | PubMed |
description | This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h in an incubation shaker at 37 °C and 112 rpm. Extraction was performed following ISO 10993-12 and monomers were detected and quantified by HPLC-MS/MS. In all the samples, urethane dimethacrylate (UDMA) and bisphenol A (BPA) were quantifiable. Compared to water blanks, BPA levels were only elevated in the eluates from conventional composites. In all other samples, concentrations were in the range of extraneous BPA and were therefore clinically irrelevant. Low concentrations of Bisphenol A-glycidyl methacrylate (BisGMA) were found in one BPA-free composite and in both conventional materials. Statistical analyses showed that BPA-free materials released significantly less BisGMA and no BPA, while UDMA elution was comparable to elution from conventional materials. All measured concentrations were below reported effective cytotoxic concentrations. Considering these results, the substitution of BPA-derivatives with UDMA might be beneficial since BPA-associated adverse effects are ruled out. Further studies should be enrolled to test the biocompatibility of UDMA on cells of the oral environment. |
format | Online Article Text |
id | pubmed-9656414 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96564142022-11-15 A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites Hampe, Tristan Liersch, Julia Wiechens, Bernhard Wassmann, Torsten Schubert, Andrea Alhussein, Mohammad Bürgers, Ralf Krohn, Sebastian Polymers (Basel) Article This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared (n = 40), immersed in HPLC grade water, and incubated for 24 h in an incubation shaker at 37 °C and 112 rpm. Extraction was performed following ISO 10993-12 and monomers were detected and quantified by HPLC-MS/MS. In all the samples, urethane dimethacrylate (UDMA) and bisphenol A (BPA) were quantifiable. Compared to water blanks, BPA levels were only elevated in the eluates from conventional composites. In all other samples, concentrations were in the range of extraneous BPA and were therefore clinically irrelevant. Low concentrations of Bisphenol A-glycidyl methacrylate (BisGMA) were found in one BPA-free composite and in both conventional materials. Statistical analyses showed that BPA-free materials released significantly less BisGMA and no BPA, while UDMA elution was comparable to elution from conventional materials. All measured concentrations were below reported effective cytotoxic concentrations. Considering these results, the substitution of BPA-derivatives with UDMA might be beneficial since BPA-associated adverse effects are ruled out. Further studies should be enrolled to test the biocompatibility of UDMA on cells of the oral environment. MDPI 2022-10-28 /pmc/articles/PMC9656414/ /pubmed/36365574 http://dx.doi.org/10.3390/polym14214580 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hampe, Tristan Liersch, Julia Wiechens, Bernhard Wassmann, Torsten Schubert, Andrea Alhussein, Mohammad Bürgers, Ralf Krohn, Sebastian A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title | A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title_full | A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title_fullStr | A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title_full_unstemmed | A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title_short | A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites |
title_sort | pilot study on monomer and bisphenol a (bpa) release from udma-based and conventional indirect veneering composites |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9656414/ https://www.ncbi.nlm.nih.gov/pubmed/36365574 http://dx.doi.org/10.3390/polym14214580 |
work_keys_str_mv | AT hampetristan apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT lierschjulia apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT wiechensbernhard apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT wassmanntorsten apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT schubertandrea apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT alhusseinmohammad apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT burgersralf apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT krohnsebastian apilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT hampetristan pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT lierschjulia pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT wiechensbernhard pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT wassmanntorsten pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT schubertandrea pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT alhusseinmohammad pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT burgersralf pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites AT krohnsebastian pilotstudyonmonomerandbisphenolabpareleasefromudmabasedandconventionalindirectveneeringcomposites |